PLATINUM GLASSY-CARBON ELECTRODE AS DETECTOR FOR LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROXYL-CONTAINING COMPOUNDS

被引:14
作者
CASELLA, IG
机构
[1] Dipartimento di Chimica, Universita degli Studi della Basilicata, 85100 Potenza
关键词
LIQUID CHROMATOGRAPHY; AMPEROMETRY; SENSORS; ALCOHOLS;
D O I
10.1016/0003-2670(95)00159-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A platinum-modified glassy carbon electrode was investigated as an amperometric sensor for the determination of alcoholic species in acidic medium. The described electrode was tested in liquid chromatography and flow-injection analysis by pulsed amperometric detection. It showed a promising combination among catalytic activity, detection limits and reproducibility for the determination of alcoholic species. The electrode response was stable; over 8 h a signal loss of less than 5% was observed. Linear responses at low concentrations yielded detection limits in the 0.6-1.8 mu g ml(-1) ranges for the various aliphatic alcohols. Typical relative standard deviations were comprised between 1.2% and 3.8% for all mono- and polyhydric compounds investigated. Linear plots of 1/I-p, and 1/C indicated Langmuir-type adsorption of analytes on the electrode surface. The Pt chemically modified electrode showed a few important differences with the bulk platinum electrode: i.e., a greater extension of linear range for relatively high concentrations and different trend of sensitivity towards the catalytic oxidation of mono-and polyhydric species.
引用
收藏
页码:37 / 46
页数:10
相关论文
共 28 条
[1]  
BURKE LD, 1986, MODERN ASPECT ELECTR, V18
[2]   STUDY OF A NICKEL-CATALYZED GLASSY-CARBON ELECTRODE FOR DETECTION OF CARBOHYDRATES IN LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
CASELLA, IG ;
DEIMONI, F ;
CATALDI, TRI .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :117-125
[3]   ELECTROCATALYTIC OXIDATION AND LIQUID-CHROMATOGRAPHIC DETECTION OF ALIPHATIC-ALCOHOLS AT A NICKEL-BASED GLASSY-CARBON MODIFIED ELECTRODE [J].
CASELLA, IG ;
CATALDI, TRI ;
SALVI, AM ;
DESIMONI, E .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3143-3150
[4]   COBALT-BASED GLASSY-CARBON CHEMICALLY MODIFIED ELECTRODE FOR CONSTANT-POTENTIAL AMPEROMETRIC DETECTION OF CARBOHYDRATES IN FLOW-INJECTION ANALYSIS AND LIQUID-CHROMATOGRAPHY [J].
CATALDI, TRI ;
CASELLA, IG ;
DESIMONI, E ;
ROTUNNO, T .
ANALYTICA CHIMICA ACTA, 1992, 270 (01) :161-171
[5]   KINETICS AND MECHANISM OF OXIDATION OF AMINES AND ALCOHOLS AT OXIDE-COVERED NICKEL, SILVER, COPPER, AND COBALT ELECTRODES [J].
FLEISCHM.M ;
PLETCHER, D ;
KORINEK, K .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1972, (10) :1396-&
[6]   ELECTROCHEMICAL PREPARATION AND ANALYTICAL APPLICATIONS OF ULTRATHIN OVEROXIDIZED POLYPYRROLE FILMS [J].
HSUEH, CC ;
BRAJTERTOTH, A .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2458-2464
[7]  
JACKSON JF, 1988, MODERN METHODS PLANT, V6
[8]   ELECTRODES MODIFIED WITH COBALT HEXACYANOFERRATE [J].
JOSEPH, J ;
GOMATHI, H ;
RAO, GP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 304 (1-2) :263-269
[9]   ELECTROCATALYTIC OXIDATION OF ETHYLENE-GLYCOL .1. BEHAVIOR OF PLATINUM AD-ATOM ELECTRODES IN ACID-MEDIUM [J].
KADIRGAN, F ;
BEDEN, B ;
LAMY, C .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 136 (01) :119-138
[10]   SORBITOL DEHYDROGENASE REACTOR FOR FLUOROMETRIC DETECTION OF ALDITOLS IN A LIQUID-CHROMATOGRAPHIC SYSTEM [J].
KIBA, N ;
MATSUSHITA, R ;
OYAMA, Y ;
FURUSAWA, M .
ANALYTICA CHIMICA ACTA, 1991, 248 (02) :367-370