CROWN-ETHER DERIVATIVES OF ANTHRAQUINONE AS IONOPHORES IN ION-SELECTIVE ELECTRODES

被引:11
|
作者
ALLEN, JR
CYNKOWSKI, T
DESAI, J
BACHAS, LG
机构
[1] UNIV KENTUCKY,DEPT CHEM,LEXINGTON,KY 40506
[2] UNIV KENTUCKY,CTR MEMBRANE SCI,LEXINGTON,KY 40506
[3] AGR UNIV WARSAW,INST GEN CHEM,PL-02528 WARSAW,POLAND
关键词
IONOPHORE; ION SELECTIVE ELECTRODE; ANTHRAQUINONE; POTASSIUM;
D O I
10.1002/elan.1140040504
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
1,8-anthraquinono-18-crown-6 and 10-[(2,4-dinitrophenyl)azo]-9-hydroxy-1,8-anthraceno-18-crown-6 were prepared from 1, 8-dichloroanthraquinone and used in the development of ion-selective electrodes. The electrodes based on 10-[(2,4-dinitrophenyl)azo]-9-hydroxy-1,8-anthraceno-18-crown-6 displayed better selectivity for potassium over sodium and had fewer interferences. The differences and similarities between the ionophores, as well as the optimum conditions for the preparation of the electrodes are discussed.
引用
收藏
页码:533 / 537
页数:5
相关论文
共 50 条
  • [1] CROWN-ETHER IONOPHORES - CONSTRUCTION OF NEUTRAL CARRIER ION-SELECTIVE ELECTRODES
    MORIARTY, RM
    RAO, MSC
    TULADHAR, SM
    DSILVA, C
    WILLIAMS, G
    GILARDI, R
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (03) : 1194 - 1196
  • [2] ION-SELECTIVE CROWN-ETHER ELECTRODES FOR LOCAL-ANESTHETIC CATIONS
    SHIRAHAMA, K
    KAMAYA, H
    UEDA, I
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1983, 16 (19): : 1485 - 1494
  • [3] Enantiomer-selectivity of ion-selective electrodes based on a chiral crown-ether ionophore
    Horvath, V
    Takacs, T
    Horvai, G
    Huszthy, P
    Bradshaw, JS
    Izatt, RM
    ANALYTICAL LETTERS, 1997, 30 (09) : 1591 - 1609
  • [4] NAPHTHO-CROWN ETHERS AS IONOPHORES IN ION-SELECTIVE ELECTRODES
    BLAIR, TL
    DAUNERT, S
    BACHAS, LG
    ANALYTICA CHIMICA ACTA, 1989, 222 (02) : 253 - 261
  • [5] BENZO-18-CROWN-6 AND ITS LARIAT ETHER DERIVATIVES AS IONOPHORES FOR POTASSIUM, STRONTIUM, AND LEAD ION-SELECTIVE ELECTRODES
    ATTIYAT, AS
    CHRISTIAN, GD
    CASON, CV
    BARTSCH, RA
    ELECTROANALYSIS, 1992, 4 (01) : 51 - 56
  • [6] BIS-CROWN ETHER DERIVATIVES AS IONOPHORES FOR POTASSIUM SELECTIVE ELECTRODES
    LINDNER, E
    TOTH, K
    HORVATH, M
    PUNGOR, E
    AGAI, B
    BITTER, I
    TOKE, L
    HELL, Z
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (02): : 157 - 163
  • [7] LIPOPHILIC CROWN-4 DERIVATIVES AS LITHIUM IONOPHORES FOR LITHIUM ION-SELECTIVE LIQUID MEMBRANE ELECTRODES
    KIM, JS
    JUNG, SO
    LEE, SS
    KIM, SJ
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1993, 14 (01) : 123 - 127
  • [8] LITHIUM ION-SELECTIVE ELECTRODES BASED ON 14-CROWN-4 DERIVATIVES BEARING LIPOPHILIC SUBSTITUENTS AS IONOPHORES
    SAKAMOTO, H
    MIURA, T
    TANAKA, M
    SHONO, T
    BUNSEKI KAGAKU, 1990, 39 (11) : 779 - 783
  • [9] Ionophores in rubidium ion-selective membrane electrodes
    Hyun, MH
    Piao, MH
    Cho, YJ
    Shim, YB
    ELECTROANALYSIS, 2004, 16 (21) : 1785 - 1790
  • [10] BIS-(CROWN ETHER) ION-SELECTIVE ELECTRODES AND THEIR POTENTIAL APPLICATION
    FU, PC
    ZIC, V
    DAFFERN, M
    FEISTEL, C
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1986, 16 (04): : 328 - 329