CORONA PERFORMANCE OF A CONDUCTOR BUNDLE FOR BIPOLAR HVDC TRANSMISSION AT +/-750 KV

被引:0
|
作者
SARMAMARUVADA, P
GIAOTRINH, N
DALLAIRE, D
RIVEST, N
机构
[1] HYDRO QUEBEC INST RES,VARENNES,QUEBEC,CANADA
[2] HYDRO QUEBEC INST RES,HIGH VOLTAGE RES GRP,VARENNES,QUEBEC,CANADA
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:1872 / 1881
页数:10
相关论文
共 50 条
  • [21] Influence of glaze icing on corona inception voltage of bundle conductor for transmission lines
    Chen, Ji
    Jiang, Xingliang
    Shu, Lichun
    Hu, Jianlin
    Zhang, Man
    Li, Yuanjun
    Chen, J. (chenji19850104@cqu.edu.cn), 1600, Science Press (40): : 395 - 404
  • [22] The influence of contaminations on HVDC conductor corona characteristics
    Ma, Minhua
    Zhao, Yuming
    Guan, Zhicheng
    Wang, Liming
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 537 - +
  • [23] Corona ionized field analysis of ±800kV HVDC transmission lines
    Yuan, Haiyan
    Fu, Zhengcai
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2010, 25 (02): : 139 - 146
  • [24] Corona losses in HVdc bipolar lines
    Corbellini, U
    Pelacchi, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1475 - 1481
  • [25] Corona losses in HVdc bipolar lines
    Univ of Pisa, Pisa, Italy
    IEEE Trans Power Delivery, 3 (1475-1481):
  • [26] Numerical Calculations of Monopolar Corona From the Bare Bundle Conductors of HVDC Transmission Lines
    Li, Zhong-Xin
    Li, Guang-Fan
    Fan, Jian-Bin
    Su, Zhi-Yi
    Gu, Chen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1579 - 1585
  • [27] CORONA PERFORMANCE OF A plus or minus 450-KV BIPOLAR DC TRANSMISSION LINE CONFIGURATION.
    Dallaire, R.D.
    Maruvada, P.Sarma
    IEEE Transactions on Power Delivery, 1987, PWRD-2 (02) : 477 - 485
  • [28] CORONA LOSS OF 3-CONDUCTOR BUNDLE
    SUGIMOTO, T
    ELECTRICAL ENGINEERING IN JAPAN, 1968, 88 (09) : 23 - &
  • [29] Influence of sandy condition on corona loss characteristic of the 750 kV bundle conductors in high altitude area
    Zhu, Lei
    Liu, Yunpeng
    Geng, Jianghai
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (22): : 5924 - 5932
  • [30] Effects of rainfall on the corona characteristics of AC single conductor of 110 kV transmission lines
    Hu, Qin
    Wang, Huan
    Wu, Weiwei
    Shu, Lichun
    Wu, Yufan
    Jiang, Xingliang
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 234