COMPUTERIZED ANALYSIS OF FETAL HEART-RATE .1. DESCRIPTION OF THE SYSTEM (2CTG)

被引:0
|
作者
ARDUINI, D
RIZZO, G
PIANA, G
BONALUMI, A
BRAMBILLA, P
ROMANINI, C
机构
来源
JOURNAL OF MATERNAL-FETAL INVESTIGATION | 1993年 / 3卷 / 03期
关键词
FETAL HEART RATE; ACCELERATIONS; DECELERATIONS; COMPUTER; AUTOMATIC ANALYSIS; FETAL BEHAVIOR;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The object of this study was to develop an automatic system for the on-line analysis of fetal heart rate based on a low cost personal computer and allowing a reliable identification of both baseline and fetal heart rate patterns. Methods: An on-line method of baseline identification has been constructed on the implementation of the off-line method described by Mantel et al.6 Based on the determination of the baseline, accelerations and decelerations were identified, short- and long-term variability indices were measured, and fetal heart rate patterns (A to D) were identified. The results of the baseline fitting were evaluated on 20 tracings lasting 2 h. The on-line method developed was compared with the original off-line method by considering the agreement of a panel of five experts on baseline fitting and by regression analysis between the absolute values of baseline obtained. Tracings (169) lasting greater-than-or-equal-to 60 min from uneventful pregnancies at 31-42 weeks' gestation were also evaluated and the relationships between the fetal heart parameters were measured and both gestational age and fetal heart rate patterns were analyzed. Results: The panel of experts judged that in 70% of the cases, both methods fitted the baseline in an equivalent way. In the remaining 30% of the cases, experts frequently disagreed on considering the best fitting methods. Regression analysis showed a high coefficient of correlation (r = 0.92, P less-than-or-equal-to 0.001) between the baseline estimation of the two methods, with a maximum difference in baseline values of 4 beats per min (bpm) (median 2 bpm). Significant changes of baseline and the number and amplitude of accelerations were evidenced with advancing gestation. Significantly lower values of fetal heart variability were found during fetal heart rate pattern A when compared with pattern B. Conclusions: The automatic system of fetal heart analysis developed provides a reliable on-line identification of the baseline, a detection of accelerations and decelerations, and a measurement of fetal heart rate variability. Finally, by identifying the fetal heart rate patterns, it allows the study of fetal heart rate variability in relation to fetal behavior, a tool that may further validate this technique.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [21] ANTEPARTUM FETAL HEART-RATE MONITORING .1. A SEMI-QUANTITATIVE EVALUATION OF THE NON-STRESSED FETAL HEART-RATE
    BREART, G
    GOUPIL, F
    LEGRAND, H
    VAQUIER, J
    ROCHART, F
    MILLIEZ, J
    SUREAU, C
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1981, 11 (04): : 227 - 237
  • [22] AUSCULTATED FETAL HEART-RATE ACCELERATIONS .1. ACCURACY AND DOCUMENTATION
    PAINE, LL
    PAYTON, RG
    JOHNSON, TRB
    JOURNAL OF NURSE-MIDWIFERY, 1986, 31 (02): : 68 - 72
  • [23] SINUSOIDAL FETAL HEART-RATE .1. CLINICAL-SIGNIFICANCE
    YOUNG, BK
    KATZ, M
    WILSON, SJ
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 136 (05) : 587 - 593
  • [24] COMPUTERIZED ANALYSIS OF FETAL HEART-RATE VARIATION IN POSTTERM PREGNANCY - PREDICTION OF INTRAPARTUM FETAL DISTRESS AND FETAL ACIDOSIS
    WEINER, Z
    FARMAKIDES, G
    SCHULMAN, H
    KELLNER, L
    PLANCHER, S
    MAULIK, D
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (04) : 1132 - 1138
  • [25] ANALYSIS OF FETAL HEART-RATE FLUCTUATIONS
    CRAWFORD, JW
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1976, 83 (07): : 589 - 589
  • [26] OBSERVATIONS IN PERINATAL HEART-RATE MONITORING .1. QUANTITATIVE METHOD OF DESCRIBING BASELINE VARIABILITY OF FETAL HEART-RATE
    YOUNG, BK
    WEINSTEIN, HN
    HOCHBERG, HM
    GEORGE, MED
    JOURNAL OF REPRODUCTIVE MEDICINE, 1978, 20 (04) : 205 - 212
  • [27] STUDY OF FETAL HEART-RATE DECELERATION AREAS .1. PRELIMINARY EXPLORATION
    TOURNAIRE, M
    YEH, SY
    FORSYTHE, A
    HON, EH
    OBSTETRICS AND GYNECOLOGY, 1973, 42 (05): : 711 - 717
  • [28] THE VALIDATION OF A COMPUTERIZED SYSTEM FOR THE INTERPRETATION OF THE ANTEPARTUM FETAL HEART-RATE TRACINGS (VERSION 89 2.34)
    BEKSAC, MS
    ONDEROGLU, LS
    OZDEMIR, K
    KARAKAS, U
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1991, 42 (01): : 9 - 14
  • [29] CLINICAL-EXPERIENCE WITH ANTEPARTUM COMPUTERIZED FETAL HEART-RATE MONITORING
    SCHNEIDER, EP
    SCHULMAN, H
    FARMAKIDES, G
    CHAN, L
    JOURNAL OF MATERNAL-FETAL INVESTIGATION, 1992, 2 (01): : 41 - 44
  • [30] COMPUTERIZED MEASUREMENT OF FETAL HEART-RATE VARIATION IN A CASE OF FETOMATERNAL HEMORRHAGE
    BURCH, D
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1994, 101 (12): : 1089 - 1090