X-RAY-FLUORESCENCE AND QUANTITATIVE PARTICULATE MATTER ANALYSIS

被引:0
|
作者
DECHATEAUBOURG, P
QUISEFIT, JP
GARIVAIT, S
STEINER, E
GOYON, C
机构
关键词
X-RAY FLUORESCENCE; THIN FILM; AEROSOL; QUANTITATIVE ANALYSIS; STABILITY CHECKING;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
X-ray fluorescence spectroscopy allows the quantitative analysis of a large number of chemical elements in the particulate matter found on filters, provided it can be considered as a thin layer With this aim, we have adjusted sampling procedures adapted to both the explored surroundings and specific criteria associated with the technique. Because of their transparency to the exciting X-rays, the analysis of thin films requires an optimization of the sample holder by the addition of a secondary cover We have previously studied the influence of the nature of this cover on the detection limit. Several calibration methods have been described in the literature and have been extensively used. We have looked into the problem of checking the stability between analysis sets and new calibration after an instrumental modification. A synthetic bulk reference sample can take into account the instrumental variations (current, tension applied to the generator). These bulk samples (with a pre-defined content) can be used as equivalent standard filters when an X-ray tube is changed. These quantitative analysis methods have been applied to the filtration of materials (geostandards) suspended in cyclohexane. This method gives quantitative results because the statistical deviations do not exceed 5%, whatever the element.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [31] X-RAY-FLUORESCENCE ANALYSIS OF SOLUTIONS
    SMAGUNOVA, AN
    BAZYKINA, EN
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1985, 40 (05): : 609 - 623
  • [32] X-RAY-FLUORESCENCE ANALYSIS OF ROCKS
    AFONIN, VP
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (01): : 54 - 57
  • [33] ADVANCES IN X-RAY-FLUORESCENCE ANALYSIS
    AFONIN, VP
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1980, 35 (12): : 1589 - 1600
  • [34] X-RAY-FLUORESCENCE ANALYSIS OF CEMENTS
    FRECHETTE, G
    HEBERT, JC
    THINH, TP
    ANALYTICAL CHEMISTRY, 1979, 51 (07) : 957 - 961
  • [35] HYBRID X-RAY-FLUORESCENCE ANALYSIS
    KRAMER, J
    EBEL, H
    TSCHISMAROV, F
    X-RAY SPECTROMETRY, 1977, 6 (01) : 30 - 36
  • [36] NEW METHOD OF EVALUATION FOR X-RAY-FLUORESCENCE ANALYSIS .1. PROBLEMS OF X-RAY-FLUORESCENCE ANALYSIS
    SUCHOMEL, J
    UMLAND, F
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 300 (04): : 257 - 262
  • [37] COMPLETE QUANTITATIVE-ANALYSIS USING BOTH X-RAY-FLUORESCENCE AND X-RAY-DIFFRACTION
    GARBAUSKAS, MF
    GOEHNER, RP
    ADVANCES IN X-RAY ANALYSIS, 1982, 25 : 283 - 288
  • [38] AUTOMATIC PARTICULATE SULFUR MEASUREMENTS WITH A DICHOTOMOUS SAMPLER AND ONLINE X-RAY-FLUORESCENCE ANALYSIS
    JAKLEVIC, JM
    LOO, BW
    FUJITA, TY
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (06) : 687 - 690
  • [39] AUTOMATIC PARTICULATE SULFUR MONITOR USING A DICHOTOMOUS SAMPLER AND X-RAY-FLUORESCENCE ANALYSIS
    JAKLEVIC, JM
    ADACHI, RS
    GOULDING, FS
    LANDIS, DA
    LOO, BW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 267 - 267
  • [40] TUBE-EXCITED ENERGY-DISPERSIVE X-RAY-FLUORESCENCE ANALYSIS .2. ENERGY-DISPERSIVE X-RAY-FLUORESCENCE ANALYSIS OF AIR PARTICULATE MATERIAL