FLUORESCENCE ENERGY-TRANSFER DYE-LABELED PRIMERS FOR DNA-SEQUENCING AND ANALYSIS

被引:215
作者
JU, JY
RUAN, CC
FULLER, CW
GLAZER, AN
MATHIES, RA
机构
[1] UNIV CALIF BERKELEY,DEPT CHEM,BERKELEY,CA 94720
[2] UNIV CALIF BERKELEY,DEPT MOLEC & CELL BIOL,BERKELEY,CA 94720
[3] AMERSHAM LIFE SCI CORP,CLEVELAND,OH 44128
关键词
FORSTER ENERGY TRANSFER; OLIGODEOXYNUCLEOTIDE SYNTHESIS; PRIMER LABELING; FLUORESCENT TAGS;
D O I
10.1073/pnas.92.10.4347
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fluorescent dye-labeled DNA primers have been developed that exploit fluorescence energy transfer (ET) to optimize the absorption and emission properties of the label, These primers carry a fluorescein derivative at the 5' end as a common donor and other fluorescein and rhodamine derivatives attached to a modified thymidine residue within the primer sequence as accepters. Adjustment of the donor-acceptor spacing through the placement of the modified thymidine in the primer sequence allowed generation of four primers, all having strong absorption at a common excitation wavelength (488 nm) and fluorescence emission maxima of 525, 555, 580, and 605 nm, The ET efficiency of these primers ranges from 65% to 97%, and they exhibit similar electrophoretic mobilities by gel electrophoresis, With argon-ion laser excitation, the fluorescence of the ET primers and of the DNA sequencing fragments generated with ET primers is 2- to 6-fold greater than that of the corresponding primers or fragments labeled with single dyes, The higher fluorescence intensity of the ET primers allows DNA sequencing with one-fourth of the DNA template typically required when using T7 DNA polymerase, With single-stranded M13mp18 DNA as the template, a typical sequencing reaction with ET primers on a commercial sequencer provided DNA sequences with 99.8% accuracy in the first 500 bases. ET primers should be generally useful in the development of other multiplex DNA sequencing and analysis methods.
引用
收藏
页码:4347 / 4351
页数:5
相关论文
共 29 条
[11]  
Forster T, 1965, MODERN QUANTUM CHE 3, V3, P93
[12]   FLUORESCENT TANDEM PHYCOBILIPROTEIN CONJUGATES - EMISSION WAVELENGTH SHIFTING BY ENERGY-TRANSFER [J].
GLAZER, AN ;
STRYER, L .
BIOPHYSICAL JOURNAL, 1983, 43 (03) :383-386
[13]   COLLOIDAL SILICA AS A STANDARD FOR MEASURING ABSOLUTE FLUORESCENCE YIELD [J].
HERCULES, DM ;
FRANKEL, H .
SCIENCE, 1960, 131 (3413) :1611-1612
[14]   DNA SEQUENCING USING CAPILLARY ARRAY ELECTROPHORESIS [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2149-2154
[15]   FLUORESCENCE QUANTUM YIELD OF CRESYL VIOLET IN METHANOL AND WATER AS A FUNCTION OF CONCENTRATION [J].
ISAK, SJ ;
EYRING, EM .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (04) :1738-1742
[16]  
LEE LG, 1992, NUCLEIC ACIDS RES, V208, P2471
[17]   CAPILLARY ARRAY ELECTROPHORESIS - AN APPROACH TO HIGH-SPEED, HIGH-THROUGHPUT DNA SEQUENCING [J].
MATHIES, RA ;
HUANG, XC .
NATURE, 1992, 359 (6391) :167-169
[18]   THE ESTIMATION OF DISTANCES BETWEEN SPECIFIC BACKBONE-LABELED SITES IN DNA USING FLUORESCENCE RESONANCE ENERGY-TRANSFER [J].
OZAKI, H ;
MCLAUGHLIN, LW .
NUCLEIC ACIDS RESEARCH, 1992, 20 (19) :5205-5214
[19]   LIGHT-GENERATED OLIGONUCLEOTIDE ARRAYS FOR RAPID DNA-SEQUENCE ANALYSIS [J].
PEASE, AC ;
SOLAS, D ;
SULLIVAN, EJ ;
CRONIN, MT ;
HOLMES, CP ;
FODOR, SPA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (11) :5022-5026
[20]  
PISAWILLIAMSON D, 1992, COMMENTS, V19, P29