AN IN-VITRO EVALUATION OF VARIOUS SPACER DEVICES FOR METERED-DOSE INHALERS USING THE TWIN-IMPINGER

被引:14
作者
HOLZNER, PM [1 ]
MULLER, BW [1 ]
机构
[1] CHRISTIAN ALBRECHTS UNIV KIEL,DEPT PHARMACEUT & BIOPHARMACEUT,D-24118 KIEL,GERMANY
关键词
SPACER DEVICE; VALVE; IN VITRO EVALUATION; METERED DOSE INHALER; PARTICLE DEPOSITION; TWIN IMPINGER; AEROSOL;
D O I
10.1016/0378-5173(94)90277-1
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Spacer devices are a useful tool in inhalation therapy with metered-dose inhalers (MDI). Various spacers with different shapes and sizes are currently on the market. This study intends to evaluate nine commercial spacers for use with MDIs. These devices were tested in combination with two different cromolyn-sodium MDIs. The assessment has been carried out using the Twin Impinger. The fractions of the dose remaining in actuator and spacer and the fractions delivered to stage 1 (D-50% > 6.4 mu m) and stage 2 (D-50% < 6.4 mu m) of the Twin Impinger were calculated and compared to a control experiment without spacer. Deposition in stage 1 is significantly reduced for all spacers. The differences indicated that the spacers are not equivalent. Some spacers increase the fraction of the dose delivered to stage 2 whereas others strongly reduce this fraction. This effect appears to be independent of spacer volume but depends on spacer and valve construction.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 18 条
[1]   DO LARGE VOLUME SPACER DEVICES REDUCE THE SYSTEMIC EFFECTS OF HIGH-DOSE INHALED CORTICOSTEROIDS [J].
BROWN, PH ;
BLUNDELL, G ;
GREENING, AP ;
CROMPTON, GK .
THORAX, 1990, 45 (10) :736-739
[2]  
BYRON PR, 1990, RESPIRATORY DRUG DEL, P173
[3]  
CROMPTON GK, 1982, EUR J RESPIR DIS, V63, P101
[4]   INADEQUATE USE OF PRESSURIZED AEROSOLS BY ASTHMATIC-PATIENTS [J].
GAYRARD, P ;
OREHEK, J .
RESPIRATION, 1980, 40 (01) :47-52
[5]   THE TWIN IMPINGER - A SIMPLE DEVICE FOR ASSESSING THE DELIVERY OF DRUGS FROM METERED DOSE PRESSURIZED AEROSOL INHALERS [J].
HALLWORTH, GW ;
WESTMORELAND, DG .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1987, 39 (12) :966-972
[6]   SPACER DEVICES USED WITH METERED-DOSE INHALERS - BREAKTHROUGH OR GIMMICK [J].
KONIG, P .
CHEST, 1985, 88 (02) :276-284
[7]   USE OF ANALYTICALLY DEFINED ESTIMATES OF AEROSOL RESPIRABLE FRACTION TO PREDICT LUNG DEPOSITION PATTERNS [J].
MARTONEN, TB ;
KATZ, I ;
FULTS, K ;
HICKEY, AJ .
PHARMACEUTICAL RESEARCH, 1992, 9 (12) :1634-1639
[8]   FRACTION OF DOSE EXHALED AFTER ADMINISTRATION OF PRESSURIZED INHALATION AEROSOLS [J].
MOREN, F ;
ANDERSSON, J .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1980, 6 (3-4) :295-300
[10]   IMPROVEMENT OF PRESSURISED AEROSOL DEPOSITION WITH NEBUHALER SPACER DEVICE [J].
NEWMAN, SP ;
MILLAR, AB ;
LENNARDJONES, TR ;
MOREN, F ;
CLARKE, SW .
THORAX, 1984, 39 (12) :935-941