l Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy

被引:14
作者
Kim, Kyung Mi [1 ]
Gwak, Mi Sook [2 ]
Choi, Soo Joo [2 ]
Kim, Myung Hee [2 ]
Park, Mi Hye [2 ]
Heo, Burn Young [2 ]
机构
[1] Hallym Univ Dongtan Sacred Heart Hosp, Dept Anesthesiol & Pain Med, Hwaseong, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Seoul, South Korea
关键词
Arterial blood pressure; Cardiac output; Carotid endarterectomy; Fluid therapy; Stroke volume;
D O I
10.4097/kjae.2013.65.3.237
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: During carotid endarterectomy (CEA), hemodynamic stability and adequate fluid management are crucial to prevent perioperative cerebral stroke, myocardial infarction and hyperperfusion syndrome. Both pulse pressure variation (PPV) and stroke volume variation (SVV), dynamic preload indices derived from the arterial waveform, are increasingly advocated as predictors of fluid responsiveness in mechanically ventilated patients. The aim of this study was to evaluate the accuracy of PPV and SVV for predicting fluid responsiveness in patients undergoing CEA. Methods: Twenty seven patients undergoing CEA were enrolled in this study. PPV, SVV and cardiac output (CO) were measured before and after fluid loading of 500 ml of hydroxyethyl starch solution. Fluid responsiveness was defined as an increase in CO >= 15%. The ability of PPV and SVV to predict fluid responsiveness was assessed using receiver operating characteristic (ROC) analysis. Results: Both PPV and SVV measured before fluid loading are associated with changes in CO caused by fluid expansion. The ROC analysis showed that PPV and SVV predicted response to volume loading (area under the ROC curve = 0.854 and 0.841, respectively, P < 0.05). A PPV >= 9.5% identified responders (Rs) with a sensitivity of 71.4% and a specificity of 90.9%, and a SVV >= 7.5% identified Rs with a sensitivity of 92.9% and a specificity of 63.6%. Conclusions: Both PPV and SVV values before volume loading are associated with increased CO in response to volume expansion. Therefore, PPV and SVV are useful predictors of fluid responsiveness in patients undergoing CEA.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
[41]   Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor [J].
Stens, Jurre ;
Oeben, Jeroen ;
Van Dusseldorp, Ab A. ;
Boer, Christa .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (05) :587-594
[42]   Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor [J].
Jurre Stens ;
Jeroen Oeben ;
Ab A. Van Dusseldorp ;
Christa Boer .
Journal of Clinical Monitoring and Computing, 2016, 30 :587-594
[43]   Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study [J].
Didier Jacques ;
Karim Bendjelid ;
Serge Duperret ;
Joëlle Colling ;
Vincent Piriou ;
Jean-Paul Viale .
Critical Care, 15
[44]   Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies [J].
Freitas, F. G. R. ;
Bafi, A. T. ;
Nascente, A. P. M. ;
Assuncao, M. ;
Mazza, B. ;
Azevedo, L. C. P. ;
Machado, F. R. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (03) :402-408
[45]   Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery [J].
Biais, M. ;
Bernard, O. ;
Ha, J. C. ;
Degryse, C. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2010, 104 (04) :407-413
[46]   Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position [J].
Yang, S. -Y. ;
Shim, J. -K. ;
Song, Y. ;
Seo, S. -J. ;
Kwak, Y. -L. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (05) :713-720
[47]   Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy [J].
Guinot, P. -G. ;
de Broca, B. ;
Bernard, E. ;
Abou Arab, O. ;
Lorne, E. ;
Dupont, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (04) :660-664
[48]   Ultrasound stroke volume variation induced by passive leg raising and fluid responsiveness: An observational cohort study [J].
Trifi, A. ;
Abdellatif, S. ;
Daly, F. ;
Nasri, R. ;
Touitu, Y. ;
Ben Lakhal, S. .
MEDICINA INTENSIVA, 2019, 43 (01) :10-17
[49]   Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness [J].
Mallat, J. ;
Meddour, M. ;
Durville, E. ;
Lemyze, M. ;
Pepy, F. ;
Temime, J. ;
Vangrunderbeeck, N. ;
Tronchon, L. ;
Thevenin, D. ;
Tavernier, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) :449-456
[50]   Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery [J].
Kramer, A ;
Zygun, D ;
Hawes, H ;
Easton, P ;
Ferland, A .
CHEST, 2004, 126 (05) :1563-1568