l Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy

被引:14
|
作者
Kim, Kyung Mi [1 ]
Gwak, Mi Sook [2 ]
Choi, Soo Joo [2 ]
Kim, Myung Hee [2 ]
Park, Mi Hye [2 ]
Heo, Burn Young [2 ]
机构
[1] Hallym Univ Dongtan Sacred Heart Hosp, Dept Anesthesiol & Pain Med, Hwaseong, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Seoul, South Korea
关键词
Arterial blood pressure; Cardiac output; Carotid endarterectomy; Fluid therapy; Stroke volume;
D O I
10.4097/kjae.2013.65.3.237
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: During carotid endarterectomy (CEA), hemodynamic stability and adequate fluid management are crucial to prevent perioperative cerebral stroke, myocardial infarction and hyperperfusion syndrome. Both pulse pressure variation (PPV) and stroke volume variation (SVV), dynamic preload indices derived from the arterial waveform, are increasingly advocated as predictors of fluid responsiveness in mechanically ventilated patients. The aim of this study was to evaluate the accuracy of PPV and SVV for predicting fluid responsiveness in patients undergoing CEA. Methods: Twenty seven patients undergoing CEA were enrolled in this study. PPV, SVV and cardiac output (CO) were measured before and after fluid loading of 500 ml of hydroxyethyl starch solution. Fluid responsiveness was defined as an increase in CO >= 15%. The ability of PPV and SVV to predict fluid responsiveness was assessed using receiver operating characteristic (ROC) analysis. Results: Both PPV and SVV measured before fluid loading are associated with changes in CO caused by fluid expansion. The ROC analysis showed that PPV and SVV predicted response to volume loading (area under the ROC curve = 0.854 and 0.841, respectively, P < 0.05). A PPV >= 9.5% identified responders (Rs) with a sensitivity of 71.4% and a specificity of 90.9%, and a SVV >= 7.5% identified Rs with a sensitivity of 92.9% and a specificity of 63.6%. Conclusions: Both PPV and SVV values before volume loading are associated with increased CO in response to volume expansion. Therefore, PPV and SVV are useful predictors of fluid responsiveness in patients undergoing CEA.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [21] Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    Marx, G
    Cope, T
    McCrossan, L
    Swaraj, S
    Cowan, C
    Mostafa, SM
    Wenstone, R
    Leuwer, M
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (02) : 132 - 138
  • [22] Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery
    Guinot, P. -G.
    de Broca, B.
    Abou Arab, O.
    Diouf, M.
    Badoux, L.
    Bernard, E.
    Lorne, E.
    Dupont, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (01) : 28 - 33
  • [23] Stroke volume variation and pulse pressure variation measured at pulmonary arterial level versus pulse pressure variation measured at systemic arterial level: an exploratory study
    Slabbaert, M.
    Vandenheuvel, M.
    Wouters, P.
    ACTA ANAESTHESIOLOGICA BELGICA, 2021, 72 : 235 - 244
  • [24] Comparative study of pressure- and volume-controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients undergoing major abdominal surgery
    Lee, Ji Yeon
    Park, Hee Yeon
    Jung, Wol Seon
    Jo, Youn Yi
    Kwak, Hyun Jeong
    JOURNAL OF CRITICAL CARE, 2012, 27 (05) : 531.e9 - 531.e14
  • [25] Pulse pressure variation as a guide for volume expansion in dogs undergoing orthopedic surgery
    Fantoni, Denise T.
    Ida, Keila K.
    Gimenes, Andre M.
    Mantovani, Matheus M.
    Castro, Jacqueline R.
    Patricio, Geni C. F.
    Ambrosio, Aline M.
    Otsuki, Denise A.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (04) : 710 - 718
  • [26] Pulse pressure variation, stroke volume variation and dynamic arterial elastance
    Raphael Giraud
    Nils Siegenthaler
    Karim Bendjelid
    Critical Care, 15
  • [27] Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    Cope, T
    Marx, G
    McCrossan, L
    Swaraj, S
    Cowan, C
    Mostafa, SM
    Wenstone, R
    Leuwer, M
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (03) : 410P - 410P
  • [28] Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    Reuter, DA
    Kirchner, A
    Felbinger, TW
    Weis, FC
    Kilger, E
    Lamm, P
    Goetz, AE
    CRITICAL CARE MEDICINE, 2003, 31 (05) : 1399 - 1404
  • [29] Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
    De Backer, D
    Heenen, S
    Piagnerelli, M
    Koch, M
    Vincent, JL
    INTENSIVE CARE MEDICINE, 2005, 31 (04) : 517 - 523
  • [30] Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
    Alves de Oliveira-Costa, Clarice Daniele
    Friedman, Gilberto
    Rios Vieira, Silvia Regina
    Fialkow, Lea
    CLINICS, 2012, 67 (07) : 773 - 778