EVALUATION OF INSTRUMENTAL, NONISOTOPIC IMMUNOASSAYS (FLUORESCENCE POLARIZATION IMMUNOASSAY AND ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE) FOR CYCLOSPORINE MONITORING IN WHOLE-BLOOD AFTER KIDNEY AND LIVER-TRANSPLANTATION

被引:11
作者
BEUTLER, D [1 ]
MOLTENI, S [1 ]
ZEUGIN, T [1 ]
THORMANN, W [1 ]
机构
[1] UNIV BERN,DEPT CLIN PHARMACOL,MURTENSTR 35,CH-3010 BERN,SWITZERLAND
关键词
CYCLOSPORINE MONITORING; SPECIFIC; NONSPECIFIC LEVELS; LIVER AND KIDNEY TRANSPLANT PATIENTS;
D O I
10.1097/00007691-199210000-00014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Two new instrumental methods, an enzyme-multiplied immunoassay technique(EMIT) and a fluorescence polarization immunoassay (FPIA), were evaluated for monitoring of cyclosporine (CyA) in whole blood samples of renal and liver transplant patients. They are considered as being specific to the parent drug and they were compared with a specific radioimmunoassay (RIA) and a nonspecific FPIA. The data reveal that the novel procedures provide slightly overestimated CyA levels compared with specific RIA (6-12% for EMIT, 20-25% for FPIA). For both assays, intrarun and interrun reproducibilities were found to be in the 2-8% range. The ease of performance and the possibility of performing approximately 40 assays/h make the two methodologies very attractive for both routine and emergency analyses. These approaches are viewed to be complementary to the only previously available instrumental method, the nonspecific FPIA, which provides three- to fourfold higher CyA levels than those obtained with specific methods. Specific and nonspecific monitoring of CyA levels allowed variations in proportions of metabolites to total CyA and metabolites to be distinguished. A higher percentage and variability of cross-reacting metabolites were found in whole blood samples after liver transplantation compared with those in blood of kidney transplant recipients.
引用
收藏
页码:424 / 432
页数:9
相关论文
共 15 条
[1]  
Donatsch P, 1981, J Immunoassay, V2, P19, DOI 10.1080/01971528108062989
[2]   TROUGH LEVELS AND CONCENTRATION-TIME CURVES OF CYCLOSPORINE IN PATIENTS UNDERGOING RENAL-TRANSPLANTATION [J].
FREY, FJ ;
HORBER, FF ;
FREY, BM .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1988, 43 (01) :55-62
[3]   EVALUATION OF FLUORESCENCE POLARIZATION IMMUNOASSAY FOR DETERMINATION OF CYCLOSPORINE IN PLASMA [J].
HAYASHI, Y ;
SHIBATA, N ;
MINOUCHI, T ;
SHIBATA, H ;
ONO, T ;
SHIMAKAWA, H .
THERAPEUTIC DRUG MONITORING, 1989, 11 (02) :205-209
[4]   IMPROVED LIQUID-CHROMATOGRAPHIC ANALYSIS OF CYCLOSPORINE IN WHOLE-BLOOD WITH SOLID-PHASE (BOND-ELUT) EXTRACTION [J].
KABRA, PM ;
WALL, JH .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (2-3) :477-490
[5]  
NIEDERBERGER W, 1983, TRANSPL P, V15, P203
[6]  
QUESNIAUX V, 1987, CLIN CHEM, V33, P32
[7]  
SANGHVI A, 1988, CLIN CHEM, V34, P1904
[8]  
SAWCHUK RJ, 1981, CLIN CHEM, V27, P1368
[9]   COMPARISON OF SPECIFIC RADIOIMMUNOASSAYS FOR CYCLOSPORINE [J].
SGOUTAS, DS ;
HAMMARSTROM, M .
TRANSPLANTATION, 1989, 47 (04) :668-670
[10]   CYCLOSPORINE KINETICS IN RENAL-TRANSPLANT PATIENTS AS ASSESSED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND RADIOIMMUNOASSAY USING MONOCLONAL AND POLYCLONAL ANTIBODIES [J].
SPECK, RF ;
FREY, FJ ;
FREY, BM .
TRANSPLANTATION, 1989, 47 (05) :802-806