AMPEROMETRIC FLOW-INJECTION DETERMINATION OF GLUCOSE, URATE AND CHOLESTEROL IN BLOOD-SERUM BY USING SOME IMMOBILIZED ENZYME REACTORS AND A POLY(1,2-DIAMINOBENZENE)-COATED PLATINUM-ELECTRODE

被引:24
作者
YAO, T
SATOMURA, M
NAKAHARA, T
机构
[1] Department of Applied Chemistry, College of Engineering, University of Osaka Prefecture, Sakai, Osaka, 593
关键词
AMPEROMETRY; FLOW INJECTION; ENZYME REACTOR; POLYMER-COATED ELECTRODE; GLUCOSE; URIC ACID; CHOLESTEROL;
D O I
10.1016/0003-2670(94)80246-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose, uric acid and cholesterol in blood serum were assayed simultaneously in a flow-injection system by using a 16-way switching valve and a parallel configuration of three immobilized enzyme re actors. A poly(1,2-diaminobenzene)-coated platinum electrode was used to detect selectively hydrogen peroxide generated enzymatically into the enzyme reactors, without any interferences from oxidizable species and proteins present in serum. The precision (coefficient of variation) of the assay was better than 2% for the simultaneous assay of three species in human control serum. The assay speed was up to 38 samples per hour.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 18 条
[1]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[2]   A THIN-LAYER ELECTROCHEMICAL DETECTOR COATED WITH NAFION FILM FOR LIQUID-CHROMATOGRAPHY [J].
JI, HM ;
WANG, EK .
JOURNAL OF CHROMATOGRAPHY, 1987, 410 (01) :111-120
[3]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740
[4]  
MARKOVARGA G, 1993, ELECTROANAL, V5, P403
[5]   SIMULTANEOUS DETERMINATION OF GLUCOSE, ETHANOL AND LACTATE IN ALCOHOLIC BEVERAGES AND SERUM BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYME REACTORS [J].
MATSUMOTO, K ;
MATSUBARA, H ;
HAMADA, M ;
UKEDA, H ;
OSAJIMA, Y .
JOURNAL OF BIOTECHNOLOGY, 1990, 14 (01) :115-126
[6]   ION-EXCHANGE AND TRANSPORT OF NEUROTRANSMITTERS IN NAFION FILMS ON CONVENTIONAL AND MICROELECTRODE SURFACES [J].
NAGY, G ;
GERHARDT, GA ;
OKE, AF ;
RICE, ME ;
ADAMS, RN ;
MOORE, RB ;
SZENTIRMAY, MN ;
MARTIN, CR .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2) :85-94
[7]   SURFACE-MODIFIED ELECTROCHEMICAL DETECTOR FOR FLOW-INJECTION ANALYSIS - POLY(N,N-DIMETHYLANILINE)-COATED GLASSY-CARBON ELECTRODES [J].
OHSAKA, T ;
TAGUCHI, K ;
IKEDA, S ;
OYAMA, N .
DENKI KAGAKU, 1990, 58 (12) :1136-1142
[8]   ELECTROPOLYMERIZED 1,2-DIAMINOBENZENE AS A MEANS TO PREVENT INTERFERENCES AND FOULING AND TO STABILIZE IMMOBILIZED ENZYME IN ELECTROCHEMICAL BIOSENSORS [J].
SASSO, SV ;
PIERCE, RJ ;
WALLA, R ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1111-1117
[9]   SURFACE-MODIFIED ELECTROCHEMICAL DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
SITTAMPALAM, G ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :1608-1610
[10]   MODIFIED ELECTRODES FOR ELECTROCHEMICAL DETECTION IN FLOWING STREAMS [J].
WANG, J .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :41-48