Influence of In-Situ Scaling on Variability of Polluted Soil Erodibility Parameters

被引:5
作者
Al-Madhhachi, A. T. [1 ]
Hasan, M. B. [2 ]
机构
[1] Mustansiriyah Univ, Fac Engn, Water Resources Engn Dept, Baghdad 10047, Iraq
[2] Mustansiriyah Univ, Fac Engn, Environm Engn Dept, Baghdad 10047, Iraq
来源
POLLUTION | 2018年 / 4卷 / 04期
关键词
In-situ scaling; JET; Erodibility of polluted soils; Soil erodibility parameters; Crude oil;
D O I
10.22059/poll.2018.252263.393
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Middle and southern Iraq suffers from polluted soils due to crude oil, spilled on land, leakage from transmitting pipe networks, or petroleum products from refineries. Many researchers have studied pollution impacts on the soil in details, but there is a clear lack of investigation on the influence of crude oil on soil erodibility. Recent researches have investigated the influence of pollution on erodibility parameters, which include critical shear stress (tau(c)) and detachment factor (d(c)). The variability of d(c) and tau(c) due to different in-situ scaling has not been thoroughly established for polluted and unpolluted soils. Thus this research aims at investigating the influence of different in-situ scaling ratios (1: 1, 1: 30, and 1: 50) on variability of d(c) and tau(c) for polluted and unpolluted soils under controlled laboratory conditions, using Jet Erosion Test (JET), and tries to compare the three solution techniques (namely, Blaisdell's approach, depth scour approach, and iterative approach) to solve d(c) and tau(c) from JETs for polluted and unpolluted soils. The polluted soil samples have been prepared by submerging the soil surface with crude oil for 24 hours prior to testing. Results show that there have been statistical differences in d(c) and tau(c) between polluted and unpolluted soil samples on the dry side of water contents with no statistically significant difference of measured d(c) and tau(c) being observed across different in-situ scale ratios for polluted and unpolluted soils. All told, the study shows less variability of measured d(c) and tau(c) across different solution techniques, compared to previous study findings.
引用
收藏
页码:617 / 633
页数:17
相关论文
共 28 条
[1]  
Al-Madhhachi AT, 2013, T ASABE, V56, P901
[2]  
Al-Madhhachi AT, 2013, T ASABE, V56, P489
[3]  
Al-Madhhachi A. T, 2017, AL NAHRAIN J ENG SCI, V20, P959
[4]  
[Anonymous], [No title captured]
[5]  
[Anonymous], 2006, ANN BOOK ASTM STAND
[6]  
BLAISDELL FW, 1981, J HYDR ENG DIV-ASCE, V107, P327
[7]   Erosion function apparatus for scour rate predictions [J].
Briaud, JL ;
Ting, FCK ;
Chen, HC ;
Cao, Y ;
Han, SW ;
Kwak, KW .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2001, 127 (02) :105-113
[8]   Site-scale variability of streambank fluvial erodibility parameters as measured with a jet erosion test [J].
Daly, E. R. ;
Fox, G. A. ;
Enlow, H. K. ;
Storm, D. E. ;
Hunt, S. L. .
HYDROLOGICAL PROCESSES, 2015, 29 (26) :5451-5464
[9]  
Daly ER, 2013, T ASABE, V56, P1343
[10]  
Esmael S. A, 2018, INT J HYDROLOGY SCI