COMPUTER-ASSISTED DETERMINATION OF THE INNER TEMPERATURE AND PEAK CORRECTION FOR CAPILLARY ELECTROPHORESIS

被引:34
作者
BELLO, MS
LEVIN, EI
RIGHETTI, PG
机构
[1] UNIV MILAN,FAC PHARM,I-20133 MILAN,ITALY
[2] UNIV MILAN,DEPT BIOMED SCI & TECHNOL,I-20133 MILAN,ITALY
[3] ST PETERSBURG MACROMOLEC CPDS INST,ST PETERSBURG 199004,RUSSIA
[4] AF IOFFE PHYS TECH INST,ST PETERSBURG 194021,RUSSIA
关键词
D O I
10.1016/0021-9673(93)83250-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A statistical algorithm, software package and experimental validation are presented for the buffer temperature and electric current predictions and recalculations of peak migration times. The statistical procedure allows the calculation of the confidence intervals for the buffer temperature and electric current and shows the necessity for an accurate determination of the thermal coefficient of the buffer electric conductivity. The software package implements predictions of the buffer temperature, electric current and migration times for any given voltage and coolant temperature.
引用
收藏
页码:329 / 336
页数:8
相关论文
共 17 条
[1]   UNSTEADY HEAT-TRANSFER IN CAPILLARY ZONE ELECTROPHORESIS .1. A MATHEMATICAL-MODEL [J].
BELLO, MS ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1992, 606 (01) :95-102
[2]   PREDICTION OF CURRENT VOLTAGE DEPENDENCE AND ELECTROCHEMICAL CALIBRATION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
BELLO, MS ;
CHIARI, M ;
NESI, M ;
RIGHETTI, PG ;
SARACCHI, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 625 (02) :323-330
[3]   CAPILLARY ZONE ELECTROPHORESIS - QUANTITATIVE STUDY OF THE EFFECTS OF SOME DISPERSIVE PROCESSES ON THE SEPARATION EFFICIENCY [J].
FORET, F ;
DEML, M ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1988, 452 :601-613
[4]   THERMAL-MODEL OF CAPILLARY ELECTROPHORESIS AND A METHOD FOR COUNTERACTING THERMAL BAND BROADENING [J].
GOBIE, WA ;
IVORY, CF .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :191-210
[5]   EFFECT OF TEMPERATURE-GRADIENTS ON THE EFFICIENCY OF CAPILLARY ZONE ELECTROPHORESIS SEPARATIONS [J].
GRUSHKA, E ;
MCCORMICK, RM ;
KIRKLAND, JJ .
ANALYTICAL CHEMISTRY, 1989, 61 (03) :241-246
[6]  
Hjerten S, 1967, Chromatogr Rev, V9, P122, DOI 10.1016/0009-5907(67)80003-6
[7]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[8]   ZONE BROADENING IN ELECTROPHORESIS WITH SPECIAL REFERENCE TO HIGH-PERFORMANCE ELECTROPHORESIS IN CAPILLARIES - AN INTERPLAY BETWEEN THEORY AND PRACTICE [J].
HJERTEN, S .
ELECTROPHORESIS, 1990, 11 (09) :665-690
[9]  
HUANG XH, 1989, J CHROMATOGR, V480, P97
[10]   MINIATURIZATION IN PRESSURE AND ELECTROENDOSMOTICALLY DRIVEN LIQUID-CHROMATOGRAPHY - SOME THEORETICAL CONSIDERATIONS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1987, 24 :135-143