SPECT WITH [TC-99M]-D,L-HEXAMETHYL-PROPYLENE AMINE OXIME (HM-PAO) COMPARED WITH REGIONAL CEREBRAL BLOOD-FLOW MEASURED BY PET - EFFECTS OF LINEARIZATION

被引:91
作者
YONEKURA, Y
NISHIZAWA, S
MUKAI, T
FUJITA, T
FUKUYAMA, H
ISHIKAWA, M
KIKUCHI, H
KONISHI, J
ANDERSEN, AR
LASSEN, NA
机构
[1] KYOTO UNIV,SCH MED,DEPT NEUROL,KYOTO 606,JAPAN
[2] KYOTO UNIV,SCH MED,DEPT NEUROSURG,KYOTO 606,JAPAN
[3] RIGSHOSP,DEPT NEUROMED,DK-2100 COPENHAGEN O,DENMARK
[4] BISPEBJERG HOSP,DEPT CLIN PHYSIOL & NUCL MED,DK-2400 COPENHAGEN NV,DENMARK
关键词
D O I
10.1038/jcbfm.1988.36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:S82 / S89
页数:8
相关论文
共 20 条
[1]  
ANDERSEN A R, 1987, Nuclear Medicine Communications, V8, P549
[2]  
Baron J C, 1981, Trans Am Neurol Assoc, V105, P459
[3]  
Budinger T. F., 1979, Image reconstruction from projections. Implementation and applications, P147
[4]   EMISSION COMPUTER-ASSISTED TOMOGRAPHY WITH SINGLE-PHOTON AND POSITRON-ANNIHILATION PHOTON EMITTERS [J].
BUDINGER, TF ;
DERENZO, SE ;
GULLBERG, GT ;
GREENBERG, WL ;
HUESMAN, RH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :131-145
[5]   QUANTITATIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN-METABOLISM IN MAN USING O-15 AND POSITRON EMISSION TOMOGRAPHY - THEORY, PROCEDURE, AND NORMAL VALUES [J].
FRACKOWIAK, RSJ ;
LENZI, GL ;
JONES, T ;
HEATHER, JD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) :727-736
[6]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) :299-308
[7]   LINEARIZATION CORRECTION OF TC-99M-LABELED HEXAMETHYL-PROPYLENE AMINE OXIME (HM-PAO) IMAGE IN TERMS OF REGIONAL CBF DISTRIBUTION - COMPARISON TO C15O2 INHALATION STEADY-STATE METHOD MEASURED BY POSITRON EMISSION TOMOGRAPHY [J].
INUGAMI, A ;
KANNO, I ;
UEMURA, K ;
SHISHIDO, F ;
MURAKAMI, M ;
TOMURA, N ;
FUJITA, H ;
HIGANO, S .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (06) :S52-S60
[8]   ERROR ANALYSIS FOR THE DETERMINATION OF CEREBRAL BLOOD-FLOW WITH THE CONTINUOUS INHALATION OF O-15-LABELED CARBON-DIOXIDE AND POSITRON EMISSION TOMOGRAPHY [J].
JONES, SC ;
GREENBERG, JH ;
REIVICH, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (01) :116-124
[9]   A STATISTICAL STUDY OF THE STEADY-STATE TECHNIQUE FOR MEASURING REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN UTILIZATION USING O-15 [J].
LAMMERTSMA, AA ;
HEATHER, JD ;
JONES, T ;
FRACKOWIAK, RSJ ;
LENZI, GL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (03) :566-573
[10]   TOMOGRAPHIC STUDIES OF RCBF WITH [TC-99M] HM-PAO SPECT IN PATIENTS WITH BRAIN-TUMORS - COMPARISON WITH C15O2 CONTINUOUS INHALATION TECHNIQUE AND PET [J].
LANGEN, KJ ;
HERZOG, H ;
KUWERT, T ;
ROOSEN, N ;
ROTA, E ;
KIWIT, JCW ;
BOCK, WJ ;
FEINENDEGEN, LE .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (06) :S90-S94