CORONARY ANGIOPLASTY USING AN AUTOPERFUSION BALLOON CATHETER THROUGH A 6 FRENCH GUIDING CATHETER

被引:3
作者
WOLFF, MR [1 ]
PREWITT, KC [1 ]
BRINKER, JA [1 ]
RESAR, JR [1 ]
机构
[1] JOHNS HOPKINS MED INST,DEPT MED,DIV CARDIOL,BALTIMORE,MD 21205
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1993年 / 29卷 / 03期
关键词
ACUTE VESSEL CLOSURE; SUBINTIMAL DISSECTION; 6F GUIDING CATHETER;
D O I
10.1002/ccd.1810290315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Use of 6 French guiding catheters for elective percutaneous transluminal coronary angioplasty has been limited by lack of a compatible autoperfusion balloon catheter for management of complications such as acute vessel closure and large subintimal dissections. We describe the successful use of a lower profile autoperfusion balloon catheter through large internal lumen 6F guiding catheters for elective coronary angioplasty. These cases demonstrate the feasibility of the use of autoperfusion balloon catheters with 6F guiding catheters in elective, and presumably also in emergent, settings. (C) 1993 Wiley-Liss Inc.
引用
收藏
页码:247 / 250
页数:4
相关论文
共 13 条
[1]   INCIDENCE AND CONSEQUENCES OF PERIPROCEDURAL OCCLUSION - THE 1985-1986 NATIONAL HEART, LUNG, AND BLOOD INSTITUTE PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY REGISTRY [J].
DETRE, KM ;
HOLMES, DR ;
HOLUBKOV, R ;
COWLEY, MJ ;
BOURASSA, MG ;
FAXON, DP ;
DORROS, GR ;
BENTIVOGLIO, LG ;
KENT, KM ;
MYLER, RK .
CIRCULATION, 1990, 82 (03) :739-750
[2]   CATHETER REPERFUSION TO ALLOW OPTIMAL CORONARY-BYPASS GRAFTING FOLLOWING FAILED TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
FERGUSON, TB ;
HINOHARA, T ;
SIMPSON, J ;
STACK, RS ;
WECHSLER, AS .
ANNALS OF THORACIC SURGERY, 1986, 42 (04) :399-405
[3]   PRELIMINARY EXPERIENCE WITH 5 AND 6 FRENCH DIAGNOSTIC CATHETERS AS GUIDING CATHETERS FOR CORONARY ANGIOPLASTY [J].
KERN, MJ ;
TALLEY, JD ;
DELIGONUL, U ;
SEROTA, H ;
AGUIRRE, F ;
GUDIPATI, C ;
RING, M ;
JOSEPH, A ;
YUSSMAN, ZA ;
KULICK, D ;
SALINGER, M .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 22 (01) :60-63
[4]   ABRUPT VESSEL CLOSURE COMPLICATING CORONARY ANGIOPLASTY - CLINICAL, ANGIOGRAPHIC AND THERAPEUTIC PROFILE [J].
LINCOFE, AM ;
POPMA, JJ ;
ELLIS, SG ;
HACKER, JA ;
TOPOL, EJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (05) :926-935
[5]  
PREWITT KC, UNPUB CORONARY ANGIO
[6]   MYOCARDIAL PROTECTION DURING CORONARY ANGIOPLASTY WITH AN AUTOPERFUSION BALLOON CATHETER IN HUMANS [J].
QUIGLEY, PJ ;
HINOHARA, T ;
PHILLIPS, HR ;
PETER, RH ;
BEHAR, VS ;
KONG, YH ;
SIMONTON, CA ;
PEREZ, JA ;
STACK, RS .
CIRCULATION, 1988, 78 (05) :1128-1134
[7]  
RESAR JR, IN PRESS AM HEART J
[8]   1ST USE OF A 5 FRENCH DIAGNOSTIC CATHETER AS A GUIDING CATHETER FOR PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
SALINGER, MH ;
KERN, MJ .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 18 (04) :276-278
[9]  
SMITH JE, 1989, CIRCULATION S2, V80, P373
[10]   BENEFIT OF THE PERFUSION CATHETER FOR EMERGENCY CORONARY-ARTERY GRAFTING AFTER FAILED PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
SUNDRAM, P ;
HARVEY, JR ;
JOHNSON, RG ;
SCHWARTZ, MJ ;
BAIM, DS .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (05) :282-285