COMPARING A HIGH-DOSE DIPYRIDAMOLE SPECT IMAGING PROTOCOL WITH DOBUTAMINE AND EXERCISE STRESS-TESTING PROTOCOLS

被引:11
作者
FLEMING, RM [1 ]
ROSE, CH [1 ]
FELDMANN, KM [1 ]
机构
[1] CTR CLIN CARDIOL & RES,CEDAR RAPIDS,IA
关键词
D O I
10.1177/000331979504600701
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective. To determine the safety, sensitivity, specificity, and accuracy of high-dose dipyridamole compared with treadmill and dobutamine stress imaging protocols. Background. Nuclear imaging studies using standard dose dipyridamole provide similar results to those obtained when treadmill stress is used. Recently dobutamine tomography and planar imaging with high-dose dipyridamole have been shown to improve nuclear imaging results. Methods. One hundred fifty-nine patients were imaged with thallium, teboroxime, or sestamibi per standard single photon emission computed tomography (SPECT) protocols. Pharmacologic stress was performed in 85 people with the remainder under-going exercise testing by Bruce protocol. In this study, 0.852 mg dipyridamole was used per kilogram body weight and was infused over a four-minute period. Results from nuclear imaging were compared with those from coronary arteriograms. Results. The sensitivity and specificity of high-dose dipyridamole was 100% and 88.9%, respectively, which is statistically greater (P <0.005) than that achieved when patients were stressed by treadmill. Side effects with the higher dose of dipyridamole were easily reversed with aminophylline. The sensitivity and specificity of intravenous dobutamine was 100%, but it was used in a limited number of subjects. When patients were stressed by Bruce protocol the sensitivity was 92.5% and specificity was 42.8%. The differences were not attributable to inadequate exercise duration. Conclusions. High-dose dipyridamole is safe and easily reversed with intravenous aminophylline. The sensitivity and specificity of dipyridamole and dobutamine stress testing were statistically more accurate than results obtained with treadmill protocols when SPECT is used to image the heart. High-dose dipyridamole resulted in greater changes in heart rate and blood pressure response than seen with standard-dose dipyridamole. Associated side effects can be easily reversed with the administration of intravenous aminophylline without significant complications. The sensitivity, specificity, and accuracy of single photon emission computed tomography using high-dose dipyridamole are 100%, 88.9%, and 97.9%, respectively, for the overall presence or absence of disease when compared with coronary arteriography. This is significantly (P <0.005) greater than that obtained by treadmill nuclear imaging protocols, independent of imaging agent.
引用
收藏
页码:547 / 556
页数:10
相关论文
共 24 条
  • [1] DEPASQUALE EE, 1987, CIRCULATION, V77, P316
  • [2] ENHANCED DETECTION OF ISCHEMIC BUT VIABLE MYOCARDIUM BY THE REINJECTION OF THALLIUM AFTER STRESS REDISTRIBUTION IMAGING
    DILSIZIAN, V
    ROCCO, TP
    FREEDMAN, NMT
    LEON, MB
    BONOW, RO
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (03) : 141 - 146
  • [3] EFFECT OF THE DEGREE OF EFFORT ON THE SENSITIVITY OF THE EXERCISE TL-201 STRESS TEST IN SYMPTOMATIC CORONARY-ARTERY DISEASE
    ESQUIVEL, L
    POLLOCK, SG
    BELLER, GA
    GIBSON, RS
    WATSON, DD
    KAUL, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (03) : 160 - 165
  • [4] FLEMING R M, 1992, American Journal of Physiologic Imaging, V7, P20
  • [5] QUANTITATIVE CORONARY ARTERIOGRAPHY AND ITS ASSESSMENT OF ATHEROSCLEROSIS .1. EXAMINING THE INDEPENDENT VARIABLES
    FLEMING, RM
    HARRINGTON, GM
    GIBBS, HR
    SWAFFORD, J
    [J]. ANGIOLOGY, 1994, 45 (10) : 829 - 833
  • [6] COMPARISON OF TC-99M TEBOROXIME TOMOGRAPHY WITH AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY AND TL-201 TOMOGRAPHIC IMAGING
    FLEMING, RM
    KIRKEEIDE, RL
    TAEGTMEYER, H
    ADYANTHAYA, A
    CASSIDY, DB
    GOLDSTEIN, RA
    RODRIQUEZBIRD, J
    JONES, D
    STUART, Y
    VELASCO, F
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (06) : 1297 - 1302
  • [7] PATTERNS IN VISUAL INTERPRETATION OF CORONARY ARTERIOGRAMS AS DETECTED BY QUANTITATIVE CORONARY ARTERIOGRAPHY
    FLEMING, RM
    KIRKEEIDE, RL
    SMALLING, RW
    GOULD, KL
    STUART, Y
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (04) : 945 - 951
  • [8] FEASIBILITY OF TOMOGRAPHIC TC-99M-HEXAKIS-2-METHOXY-2-METHYLPROPYL-ISONITRILE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL AREA AT RISK AND THE EFFECT OF TREATMENT IN ACUTE MYOCARDIAL-INFARCTION
    GIBBONS, RJ
    VERANI, MS
    BEHRENBECK, T
    PELLIKKA, PA
    OCONNOR, MK
    MAHMARIAN, JJ
    CHESEBRO, JH
    WACKERS, FJ
    [J]. CIRCULATION, 1989, 80 (05) : 1277 - 1286
  • [9] GOULD KL, 1978, AM J CARDIOL, V41, P269
  • [10] HENDEL RC, 1990, J AM COLL CARDIOL, V16, P855