LASER-DOPPLER FLOWMETRY IN THE STUDY OF IN-VIVO LIVER ISCHEMIA AND REPERFUSION IN THE RAT

被引:28
|
作者
CHAVEZCARTAYA, RE
RAMIREZROMERO, P
CALNE, RY
JAMIESON, NV
机构
[1] Department of Surgery, Addenbrookes Hospital, University of Cambridge Clinical School, Cambridge CB2 2QQ, Hills Road
关键词
D O I
10.1006/jsre.1994.1075
中图分类号
R61 [外科手术学];
学科分类号
摘要
Estimation of blood flow in the microcirculation is essential in the analysis of the events that occur during organ ischemia and subsequent reperfusion. In this study the use of laser-Doppler flowmetry is evaluated as a method for studying liver blood flow in the rat using an in vivo ischemia-reperfusion model. The experimental procedure consists of the temporary interruption of blood flow to the left lateral and medial lobes of the liver and subsequent recording of the postischemic liver blood flow using a laser-Doppler flowmeter. Flow was recorded for 60 min after periods of ischemia of 30 sec (control), 30, 45, and 60 min. The reperfusion records showed a biphasic curve with a mean flow of 59.6% of the baseline after 30 min of ischemia and of 38.3 and 41.1% after 45 and 60 min of ischemia, respectively. There were statistically significant differences between all the groups and the controls, and between 45 and 30 min of ischemia but not between 45 and 60 min. This is a useful model for studying ischemic liver injury in the rat. (C) 1994 Academic Press, Inc.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 50 条
  • [41] ASSESSING VULVAR LESIONS - LASER-DOPPLER FLOWMETRY AS A POSSIBLE TECHNIQUE
    JACKSON, AE
    OSBORNE, MJ
    SEIFALIAN, A
    MACLEAN, AB
    JOURNAL OF REPRODUCTIVE MEDICINE, 1994, 39 (12) : 953 - 956
  • [42] PREDICTION OF SAMPLING DEPTH AND PHOTON PATHLENGTH IN LASER-DOPPLER FLOWMETRY
    JAKOBSSON, A
    NILSSON, GE
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) : 301 - 307
  • [43] LASER-DOPPLER FLOWMETRY - A NONINVASIVE METHOD FOR MICROVASCULAR PERFUSION MEASUREMENTS
    OBERG, PA
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 163 - 163
  • [44] RELIABILITY OF LASER-DOPPLER FLOWMETRY IN TESTING AUTOTRANSPLANTED MATURE TEETH
    MENSDORFFPOUILLY, N
    HAAS, R
    MALLATH, G
    WATZEK, G
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 464 - 464
  • [45] HUMAN BRONCHIAL PERFUSION EVALUATED WITH ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    SUNDSET, A
    HANSEN, G
    HAANAES, OC
    LINE, PD
    KVERNEBO, K
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1993, 13 (03): : 233 - 245
  • [46] INADEQUACY OF LASER-DOPPLER FLOWMETRY IN SKIN AREAS OF THE HUMAN HAND
    ERIKSEN, M
    LOSSIUS, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) : 311 - 318
  • [47] MICROCIRCULATION IN EXPERIMENTAL BRAIN EDEMA ASSESSED BY LASER-DOPPLER FLOWMETRY
    INAO, S
    KUCHIWAKI, H
    SUGITA, K
    NEUROLOGICAL RESEARCH, 1993, 15 (04) : 264 - 268
  • [48] Self-mixing laser-Doppler velocimetry for blood flowmetry
    Scalise, L
    de Mul, F
    Steenbergen, W
    Petoukhova, A
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 285 - 288
  • [49] COMPARISON OF LASER-DOPPLER FLOWMETRY AND THERMOMETRY IN THE POSTOPERATIVE MONITORING OF REPLANTATIONS
    HOVIUS, SER
    VANADRICHEM, LNA
    MULDER, HD
    VANSTRIK, R
    VANDERMEULEN, JC
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (01): : 88 - 93
  • [50] AN INVESTIGATION OF THE MICROCIRCULATION OF THE HUMAN TYMPANIC MEMBRANE WITH LASER-DOPPLER FLOWMETRY
    SCHOPS, P
    ERDL, R
    KNORR, H
    SEICHERT, N
    SCHNIZER, W
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1987, 244 (05): : 288 - 290