ASSOCIATION OF BODY-MASS INDEX AND REGIONAL FAT DISTRIBUTION WITH BLOOD-PRESSURE INVESTIGATED BY 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING IN ANDROID-TYPE OBESE WOMEN

被引:8
|
作者
GUAGNANO, MT
CUGINI, P
MERLITTI, D
MURRI, R
PALITTI, VP
SENSI, S
机构
[1] UNIV G DANNUNZIO,INST INTERNAL MED,CHIETI,ITALY
[2] UNIV ROMA LA SAPIENZA,MED CLIN 2,ROME,ITALY
关键词
REGIONAL FAT DISTRIBUTION; BODY MASS INDEX; AMBULATORY BLOOD PRESSURE MONITORING; CIRCADIAN RHYTHM; BLOOD PRESSURE;
D O I
10.3109/07420529509064499
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In 46 female outpatients with android-type obesity, body mass index (BMI) 36.6 +/- 1.0, waist to hip ratio (WHR) >0.86, and normal glucose tolerance (NGT) who were hypertensive at entry study [blood pressure (BP) >140/90 mm Hg] and in 10 clinically healthy, nonobese, normotensive women, we evaluated the relationship between BMI, fat mass, WHR, fasting blood glucose, sum of blood glucose levels during oral glucose tolerance test and casual BP levels, 24-h ambulatory BP monitoring (ABP) parameters as the 24-hour mean, day-time mean, night-time mean and, by using a periodic model of cosine regression, MESOR (midline estimating statistic of rhythm), amplitude, acrophase, and baric impact. In android obese women, a negative correlation between ABP levels (day-/night-time, MESOR, and baric impact of systolic BP; night-time and MESOR of diastolic BP) and BMI has been documented. A positive correlation between systolic BP (casual, night-time mean, MESOR, amplitude, and baric impact), diastolic baric impact, and the WHR has been found. No correlation has been demonstrated between ABP monitoring parameters, and BMI, body fat, and WHR in the control group. Our data could suggest that, when enrolling obese subjects, it must be taken into account that obesity is a heterogeneous disorder. There are in fact obese subjects with normal or impaired glucose tolerance, as well as diabetics with moderate to severe obesity and with gynecoid or android-type obesity. In our android obese subjects with NGT, the WHR rather than the BMI was found to be a better predictor of hypertension. The conflicting data on the relationship between obesity and hypertension may be reduced, improving BP measurement methods (ABP monitoring, cuff appropriateness) and using time-qualified measures (MESOR, baric impact).
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [31] 24-HOUR AMBULATORY BLOOD-PRESSURE IN MEN AND WOMEN AGED 17 TO 80 YEARS - THE ALLIED IRISH BANK STUDY
    OBRIEN, E
    MURPHY, J
    TYNDALL, A
    ATKINS, N
    MEE, F
    MCCARTHY, G
    STAESSEN, J
    COX, J
    OMALLEY, K
    JOURNAL OF HYPERTENSION, 1991, 9 (04) : 355 - 360
  • [32] Association between metabolic syndrome and parameters of 24-hour blood pressure ambulatory monitoring
    Felisbino-Mendes, Mariana Santos
    Gea-Horta, Tatiane
    Pinho Ribeiro, Antonio Luiz
    Kac, Gilberto
    de Fatima Silqueira, Salete Maria
    Velasquez-Melendez, Gustavo
    ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2011, 55 (06) : 383 - 388
  • [33] EFFECTS OF DELAPRIL HYDROCHLORIDE ON ESSENTIAL-HYPERTENSION ASSESSED BY 24-HOUR BLOOD-PRESSURE MONITORING
    HAYASHI, H
    TAKEZAWA, H
    HIRAI, M
    YAMAUCHI, K
    KATOH, K
    SUZUKI, A
    SUZUKI, M
    JOURNAL OF DRUG DEVELOPMENT AND CLINICAL PRACTICE, 1995, 7 (01): : 31 - 36
  • [34] 24-HOUR MONITORING OF BLOOD-PRESSURE AND HEART-RATE IN HEART-TRANSPLANT PATIENTS
    GIORGI, DMA
    BORTOLOTTO, LA
    SEFERIAN, P
    BOCCHI, EA
    BERNARDESSILVA, H
    PEREIRABARRETTO, AC
    BELLOTTI, G
    PILEGGI, F
    JATENE, AD
    JOURNAL OF HYPERTENSION, 1991, 9 : S340 - S341
  • [35] Tirzepatide Reduces 24-Hour Ambulatory Blood Pressure in Adults With Body Mass Index ≥27 kg/m2: SURMOUNT-1 Ambulatory Blood Pressure Monitoring Substudy
    de Lemos, James A.
    Linetzky, Bruno
    le Roux, Carel W.
    Laffin, Luke J.
    Vongpatanasin, Wanpen
    Fan, Ludi
    Hemmingway, Andrea
    Ahmad, Nadia N.
    Bunck, Mathijs C.
    Stefanski, Adam
    HYPERTENSION, 2024, 81 (04) : e41 - e43
  • [36] BODY-FAT DISTRIBUTION, BLOOD-PRESSURE AND BLOOD-GLUCOSE IN EGYPTIAN OBESE WOMEN UNDERGOING A WEIGHT CONTROL PROGRAM
    ELSHEBINI, SM
    TAPOZADA, ST
    HANNA, LM
    ZEITSCHRIFT FUR ERNAHRUNGSWISSENSCHAFT, 1993, 32 (02): : 103 - 112
  • [37] EFFECTS OF SLOW-RELEASE VERAPAMIL AND NITRENDIPINE ON OFFICE AND 24-HOUR AMBULATORY BLOOD-PRESSURE IN HYPERTENSIVE PATIENTS
    PANNARALE, G
    PUDDU, PE
    CAMPBELL, SV
    COLLAUTO, F
    STAZI, F
    REALE, A
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1992, 19 : S53 - S56
  • [38] Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device
    Lee, Huijin
    Park, Sungjoon
    Kwon, Hyuktae
    Cho, Belong
    Park, Jin Ho
    Lee, Hae-Young
    KOREAN CIRCULATION JOURNAL, 2024, 54 (02) : 93 - 104
  • [39] The Association of Pediatric Obesity With Nocturnal Non-Dipping on 24-Hour Ambulatory Blood Pressure Monitoring
    Macumber, Ian R.
    Weiss, Noel S.
    Halbach, Susan M.
    Hanevold, Coral D.
    Flynn, Joseph T.
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (05) : 647 - 652
  • [40] COST-EFFECTIVENESS OF 24-HOUR AMBULATE BLOOD-PRESSURE MONITORING EVALUATION AND TREATMENT OF ESSENTIAL-HYPERTENSION
    YAROWS, SA
    KHOURY, S
    SOWERS, JR
    AMERICAN JOURNAL OF HYPERTENSION, 1994, 7 (05) : 464 - 468