CARDIAC-OUTPUT MEASUREMENT IN CRITICAL CARE PATIENTS - THORACIC ELECTRICAL BIOIMPEDANCE VERSUS THERMODILUTION

被引:53
作者
CLANCY, TV
NORMAN, K
REYNOLDS, R
COVINGTON, D
MAXWELL, JG
机构
[1] NEW HANOVER REG MED CTR, DEPT RESPIRATORY THERAPY, WILMINGTON, NC USA
[2] UNIV N CAROLINA, SCH MED, DEPT SURG, CHAPEL HILL, NC 27514 USA
[3] NEW HANOVER REG MED CTR, DEPT SURG, WILMINGTON, NC USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 1991年 / 31卷 / 08期
关键词
D O I
10.1097/00005373-199131080-00011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Thoracic Electrical Bioimpedance (TEB) is a method for measuring cardiac performance which is noninvasive, continuous, has minimal technical requirements, and no patient risk. We used a commercially available TEB device to measure cardiac output in patients with thermodilution catheters in place. We compared the cardiac output measurements for the two modalities. We also compared the average hospital cost for initial cardiac assessment using the two techniques. The mean difference between the two cardiac output measurements was small (0.23 +/- 0.56) and not affected by the magnitude of the cardiac output readings. There was a strong correlation between CO(TD) and CO(TEB) (r = 0.91) and the regression slope was 0.91 with a Y intercept of 0.76. Cost analysis demonstrated that the use of TEB was approximately $600 less than thermodilution. Thoracic electrical bioimpedance measurement of cardiac output may offer a valuable alternative to the invasive measurement of the thermodilution catheter.
引用
收藏
页码:1116 / 1121
页数:6
相关论文
共 34 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[3]  
BARASH PG, 1981, J THORAC CARDIOV SUR, V82, P5
[4]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[5]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[6]   DETERMINATION OF CARDIAC-OUTPUT DURING POSITIVE ENDEXPIRATORY PRESSURE - NONINVASIVE ELECTRICAL BIOIMPEDANCE COMPARED WITH STANDARD THERMODILUTION [J].
CASTOR, G ;
MOLTER, G ;
HELMS, J ;
NIEDERMARK, I ;
ALTMAYER, P .
CRITICAL CARE MEDICINE, 1990, 18 (05) :544-546
[7]  
CIVETTA JM, 1988, CRITICAL CARE, P1543
[8]   COMPLICATIONS OF PULMONARY-ARTERY CATHETERIZATION IN THE CARE OF CRITICALLY ILL PATIENTS - PROSPECTIVE-STUDY [J].
ELLIOTT, CG ;
ZIMMERMAN, GA ;
CLEMMER, TP .
CHEST, 1979, 76 (06) :647-652
[9]   CARDIAC-OUTPUT DETERMINATIONS IN THE PIG - THORACIC ELECTRICAL BIOIMPEDANCE VERSUS THERMODILUTION [J].
JIVEGARD, L ;
FRID, I ;
HALJAMAE, H ;
HOLM, J ;
HOLM, S ;
WICKSTROM, I .
CRITICAL CARE MEDICINE, 1990, 18 (09) :995-998
[10]  
KUBICEK WG, 1966, AEROSPACE MED, V37, P1208