CLINICAL EVALUATION OF AUTOMATED PROCESSING OF ELECTROCARDIOGRAMS BY THE VETERANS ADMINISTRATION PROGRAM (AVA-3.4)

被引:9
作者
BROHET, CR
RICHMAN, HG
机构
[1] VET ADM HOSP,MED CTR,CARDIOVASC SECT,MINNEAPOLIS,MN 55417
[2] UNIV MINNESOTA,SCH MED,DEPT INTERNAL MED,MINNEAPOLIS,MN 55455
[3] UNIV MINNESOTA,SCH MED,DIV HLTH COMP SCI,MINNEAPOLIS,MN 55455
关键词
D O I
10.1016/0002-9149(79)90149-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automated processing of electrocardiograms by the Veterans Administration program was evaluated for both agreement with physician interpretation and interpretative accuracy as assessed with nonelectrocardiographic criteria. One thousand unselected electrocardiograms were analyzed by two reviewer groups, one familiar and the Other unfamiliar with the computer program. A significant number of measurement errors involving repolarization changes and left axis deviation occurred; however, interpretative disagreements related to statistical decision were largely language-related. Use of a printout with a more traditional format resulted in agreement with physician interpretation by both reviewer groups in more than 80 percent of cases. Overall sensitivity based on agreement with nonelectrocardiographic criteria was significantly greater with use of the computer program than with use of the conventional criteria utilized by the reviewers. This difference was particularly evident in the subgroup analysis of myocardial infarction and left ventricular hypertrophy. The degree of overdiagnosis of left ventricular hypertrophy and posteroinferior infarction was initially unacceptable, but this difficulty was corrected by adjustment of probabilities. Clinical acceptability of the Veterans Administration program appears to require greater physician education than that needed for other computer programs of electrocardiographic analysis; the flexibility of interpretation by statistical decision offers the potential for better diagnostic accuracy. © 1979.
引用
收藏
页码:1167 / 1174
页数:8
相关论文
共 25 条
[1]  
ARNAUD P, 1977, TRENDS COMPUTER PROC, P175
[2]   IMPORTANCE OF REPRODUCIBILITY TESTING OF COMPUTER-PROGRAMS FOR ELECTROCARDIOGRAPHIC INTERPRETATION - APPLICATION TO AUTOMATIC VECTORCARDIOGRAPHIC ANALYSIS PROGRAM (AVA 3.4) [J].
BAILEY, JJ ;
HORTON, M ;
ITSCOITZ, SB .
COMPUTERS AND BIOMEDICAL RESEARCH, 1976, 9 (04) :307-316
[3]   METHOD FOR EVALUATING COMPUTER-PROGRAMS FOR ELECTROCARDIOGRAPHIC INTERPRETATION .1. APPLICATION TO EXPERIMENTAL IBM PROGRAM OF 1971 [J].
BAILEY, JJ ;
ITSCOITZ, SB ;
HIRSHFELD, JW ;
GRAUER, LE ;
HORTON, MR .
CIRCULATION, 1974, 50 (01) :73-79
[4]   METHOD FOR EVALUATING COMPUTER-PROGRAMS FOR ELECTROCARDIOGRAPHIC INTERPRETATION .3. REPRODUCIBILITY TESTING AND SOURCES OF PROGRAM ERRORS [J].
BAILEY, JJ ;
HORTON, M ;
ITSCOITZ, SB .
CIRCULATION, 1974, 50 (01) :88-93
[5]  
Blackburn H, 1969, J Electrocardiol, V2, P5, DOI 10.1016/S0022-0736(69)80044-0
[6]   NEW COMPUTER-PROGRAM FOR ANALYSIS OF SCALAR ELECTROCARDIOGRAMS [J].
BONNER, RE ;
CREVASSE, L ;
FERRER, MI ;
GREENFIELD, JC .
COMPUTERS AND BIOMEDICAL RESEARCH, 1972, 5 (06) :629-653
[7]   RELIABILITY AND NORMAL VARIATIONS OF COMPUTER ANALYSIS OF FRANK ELECTROCARDIOGRAM BY SMITH-HYDE PROGRAM (1968 VERSION) [J].
BRUCE, RA ;
YARNALL, SR .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (03) :389-&
[8]   LIMITATIONS OF COMPUTER IN ELECTROCARDIOGRAPHIC INTERPRETATION [J].
CACERES, CA .
AMERICAN JOURNAL OF CARDIOLOGY, 1976, 38 (03) :362-376
[9]  
CACERES CA, 1963, ARCH INTERNAL MED, V11, P196
[10]  
CORNFIELD J, 1972, COMPUTER DIAGNOSIS D, P108