MONITORING OF POLYNUCLEAR AROMATIC-HYDROCARBONS IN WATER .2. EXTRACTION AND RECOVERY OF 6 REPRESENTATIVE COMPOUNDS WITH POLYURETHANE FOAMS

被引:44
作者
BASU, DK [1 ]
SAXENA, J [1 ]
机构
[1] SYRACUSE RES CORP,CTR CHEM HAZARD ASSESSMENT,SYRACUSE,NY 13210
关键词
D O I
10.1021/es60143a003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Flexible polyurethane foam plugs effectively concentrated trace quantities of the six representatives of the poiynuciear family from large volumes of finished and raw waters when the water was heated to 62±2°C and passed through foam plugs at a flow rate of 250±10 mL/min. The retention efficiencies of the individual PAH on the foams were no less than 88% from finished water and 72% from raw water. The purification of the concentrate was achieved by solvent partitioning and column chromatography on Florisil. The recovery of PAH from the cleanup procedure varied between 90-100%. Thin-layer chromatography coupled with fluorometric detection was more sensitive and selective than gas-liquid chromatography-flame ionization detection. The technique described detected as low as 0.1 ng/L of an individual PAH. © 1978, American Chemical Society. All rights reserved.
引用
收藏
页码:791 / 795
页数:5
相关论文
共 11 条
[1]   FACTORS AFFECTING EXTRACTION AND ANALYSIS OF POLYNUCLEAR AROMATIC-HYDROCARBONS IN WATER [J].
ACHESON, MA ;
HARRISON, RM ;
PERRY, R ;
WELLINGS, RA .
WATER RESEARCH, 1976, 10 (03) :207-212
[2]  
BORNEFF J, 1969, ARCH HYG BAKTERIOL, V153, P220
[3]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN ATMOSPHERIC PARTICULATE MATTER BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY COUPLED WITH FLUORESCENCE TECHNIQUES [J].
FOX, MA ;
STALEY, SW .
ANALYTICAL CHEMISTRY, 1976, 48 (07) :992-998
[4]   DEVELOPMENT OF A GAS CHROMATOGRAPHIC-ULTRAVIOLET ABSORPTION SPECTROMETRIC METHOD FOR MONITORING PETROLEUM PITCH VOLATILES IN ENVIRONMENT [J].
GREINKE, RA ;
LEWIS, IC .
ANALYTICAL CHEMISTRY, 1975, 47 (13) :2151-2155
[5]   SHORT-TERM DETERMINATION OF CARCINOGENIC AROMATIC HYDROCARBONS [J].
HOFFMANN, D ;
WYNDER, EL .
ANALYTICAL CHEMISTRY, 1960, 32 (02) :295-296
[6]   APPLICATION OF A GAS CHROMATOGRAPH MASS SPECTROMETER DATA PROCESSOR COMBINATION TO ANALYSIS OF POLYCYCLIC AROMATIC HYDROCARBON CONTENT OF AIRBORNE POLLUTANTS [J].
LAO, RC ;
THOMAS, RS ;
OJA, H ;
DUBOIS, L .
ANALYTICAL CHEMISTRY, 1973, 45 (06) :908-915
[7]   METHODS FOR FRACTIONATION, ANALYTICAL SEPARATION AND IDENTIFICATION OF POLYNUCLEAR AROMATIC-HYDROCARBONS IN COMPLEX MIXTURES [J].
NOVOTNY, M ;
LEE, ML ;
BARTLE, KD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (10) :606-612
[8]  
PIERCE RC, 1975, ANAL CHEM, V47, P1974
[9]  
ROWLAND FW, 1974, PRACTICE GAS CHROMAT, P25
[10]   MONITORING OF POLYNUCLEAR AROMATIC-HYDROCARBONS IN WATER .1. EXTRACTION AND RECOVERY OF BENZO(A)PYRENE WITH POROUS POLYURETHANE FOAM [J].
SAXENA, J ;
KOZUCHOWSKI, J ;
BASU, DK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1977, 11 (07) :682-685