DESIGN OF SENSOR ELECTRONICS FOR ELECTRICAL CAPACITANCE TOMOGRAPHY

被引:122
作者
HUANG, SM
XIE, CG
THORN, R
SNOWDEN, D
BECK, MS
机构
[1] S AUSTRALIAN INST TECHNOL,SCH ELECTR ENGN,ADELAIDE,AUSTRALIA
[2] SCHLUMBERGER IND,FARNBOROUGH GU14 7PW,HANTS,ENGLAND
来源
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS | 1992年 / 139卷 / 01期
关键词
TOMOGRAPHY; IMAGE PROCESSING; SENSOR ELECTRONICS;
D O I
10.1049/ip-g-2.1992.0014
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design of the sensor electronics for a tomographic imaging system based on electrical capacitance sensors is described. The performance of the sensor electronics is crucial to the performance of the imaging system. The problems associated with such a measurement process are discussed and solutions to these are described. Test results show that the present design has a resolution of 0.3 femtofarad (For a 12-electrode system imaging an oil/gas flow, this represents a 2% gas void fraction change at the centre of the pipe) with a low noise level of 0.08 fF (rms value), a large dynamic range of 76 dB and a data acquisition speed of 6600 measurements per second. This enables sensors with up to 12 electrodes to be used in a system with a maximum imaging rate of 100 frames per second, and thus provides an improved image resolution over the earlier 8-electrode system and an adequate electrode area to give sufficient measurement sensitivity.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 8 条
[1]   TOMOGRAPHIC IMAGING OF INDUSTRIAL-PROCESS EQUIPMENT - TECHNIQUES AND APPLICATIONS [J].
DICKIN, FJ ;
HOYLE, BS ;
HUNT, A ;
HUANG, SM ;
ILYAS, O ;
LENN, C ;
WATERFALL, RC ;
WILLIAMS, RA ;
XIE, CG ;
BECK, MS .
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1992, 139 (01) :72-82
[2]  
HALOW JS, 1990, AICHE S SER, V86, P41
[3]  
HOROWITZ P., 1989, ART ELECTRONICS, P396
[4]  
Huang S. M., 1988, Transactions of the Institute of Measurement and Control, V10, P98, DOI 10.1177/014233128801000206
[5]   ELECTRONIC TRANSDUCERS FOR INDUSTRIAL MEASUREMENT OF LOW VALUE CAPACITANCES [J].
HUANG, SM ;
STOTT, AL ;
GREEN, RG ;
BECK, MS .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (03) :242-250
[6]   A HIGH-FREQUENCY STRAY-IMMUNE CAPACITANCE TRANSDUCER BASED ON THE CHARGE-TRANSFER PRINCIPLE [J].
HUANG, SM ;
GREEN, RG ;
PLASKOWSKI, A ;
BECK, MS .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1988, 37 (03) :368-373
[7]  
HUANG SM, ELECTRON LETT, V24, P418
[8]  
Thorn R., 1990, Flow Measurement and Instrumentation, V1, P259, DOI 10.1016/0955-5986(90)90024-2