NECR ANALYSIS OF 3D BRAIN PET SCANNER DESIGNS

被引:22
作者
STEARNS, CW
CHERRY, SR
THOMPSON, CJ
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,LOS ANGELES,CA 90024
[2] MCGILL UNIV,MONTREAL NEUROL INST,MONTREAL,PQ,CANADA
关键词
D O I
10.1109/23.467746
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A dedicated 3D brain PET scanner has several advantages, most notably increased sensitivity, over a whole body scanner for neurological studies. However brain scanners have higher scatter fractions, random count-rates and deadtime for the same activity concentration. We have used noise effective count-rate (NECR) analysis to compare brain scanners of 53, 60, and 66 cm diameter with the GE ADVANCE whole body scanner (93 cm diameter). Monte Carlo simulations of a brain-sized phantom (16 cm diameter, 13 cm length) in the ADVANCE geometry were used to develop a model for NECR performance, which was reconciled to results from a decay series measurement. The model was then used to predict the performance of the brain scanner designs. The brain scanners have noise effective sensitivities (the slope of the NECR curve at zero activity) as much as 40% higher than the body scanner. However, their NECR advantage diminishes quickly as the activity concentration increases. The brain scanners' NECR equals the body scanner with about 0.7-0.8 mCi in the phantom; the body scanner has superior NECR performance at higher activity levels. hn imaging center concentrating on only very low activity imaging tasks would find the efficiency advantage of a smaller detector diameter valuable, while a center performing higher activity studies such as bolus water injections or 5mCi FDG injections might prefer the count rate performance of a whole body scanner.
引用
收藏
页码:1075 / 1079
页数:5
相关论文
共 7 条
[1]   DESIGN CONSIDERATIONS FOR POSITRON EMISSION TOMOGRAPHY [J].
BROOKS, RA ;
SANK, VJ ;
FRIAUF, WS ;
LEIGHTON, SB ;
CASCIO, HE ;
DICHIRO, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (02) :158-177
[2]  
DEGRADO TR, 1994, J NUCL MED, V325, P1398
[3]   A REAL-TIME DIGITAL COINCIDENCE PROCESSOR FOR POSITRON EMISSION TOMOGRAPHY [J].
DENT, HM ;
JONES, WF ;
CASEY, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :556-559
[4]  
DERENZO SE, 1975, J NUCL MED, V16, P1166
[5]   DIGITAL COINCIDENCE DETECTION - A SCANNING VLSI IMPLEMENTATION [J].
MERTENS, JD ;
BHEND, WL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (06) :2037-2039
[6]   MEASURING PET SCANNER SENSITIVITY - RELATING COUNTRATES TO IMAGE SIGNAL-TO-NOISE RATIOS USING NOISE EQUIVALENT COUNTS [J].
STROTHER, SC ;
CASEY, ME ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :783-788
[7]   PETSIM - MONTE-CARLO SIMULATION OF ALL SENSITIVITY AND RESOLUTION PARAMETERS OF CYLINDRICAL POSITRON IMAGING-SYSTEMS [J].
THOMPSON, CJ ;
MORENOCANTU, J ;
PICARD, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03) :731-749