AN ANATOMICAL FILTER FOR EXPOSURE EQUALIZATION IN MAMMOGRAPHY

被引:15
作者
PANAYIOTAKIS, G
LIKAKI, H
KOLITSI, Z
DIMOPOULOS, J
机构
[1] Department of Medical Physics, School of Medicine, University of Patras, Patras
[2] Department of Radiology, School of Medicine, University of Patras, Patras
关键词
MAMMOGRAPHY; TECHNOLOGY;
D O I
10.1016/0720-048X(92)90195-F
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An anatomical filter has been designed, tested and subsequently used in clinical practice to equalize optical density over the entire mammographic image, thus eliminating the need for dual exposure whenever both the mammary gland and the peripheral structures of the breast must be clearly visualized. The use of the filter results in a reduction of the optical density, at the peripheral structures of the breast, with a simultaneous increase of the contrast, without causing deterioration of the mammary gland image. Improved visualization of the connective tissue, the skin, the nipple and the subcutaneous adipose tissue is achieved, as well as minimization of the radiation dose to the breast for patients with an indication of peripheral breast lesions.
引用
收藏
页码:15 / 17
页数:3
相关论文
共 50 条
  • [41] INCREASED RADIATION-DOSE AT MAMMOGRAPHY DUE TO PROLONGED EXPOSURE, DELAYED PROCESSING, AND INCREASED FILM DARKENING
    KIMMESMITH, C
    BASSETT, LW
    GOLD, RH
    CHOW, S
    RADIOLOGY, 1991, 178 (02) : 387 - 391
  • [42] Feasibility study on an integrated AEC-grid device for the optimization of image quality and exposure dose in mammography
    Kyo-Tae Kim
    Ryang-Young Yun
    Moo-Jae Han
    Ye-Ji Heo
    Yong-Keun Song
    Sung-Wook Heo
    Kyeong-Min Oh
    Sung-Kwang Park
    Journal of the Korean Physical Society, 2017, 71 : 510 - 515
  • [43] Feasibility study on an integrated AEC-grid device for the optimization of image quality and exposure dose in mammography
    Kim, Kyo-Tae
    Yun, Ryang-Young
    Han, Moo-Jae
    Heo, Ye-Ji
    Song, Yong-Keun
    Heo, Sung-Wook
    Oh, Kyeong-Min
    Park, Sung-Kwang
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (08) : 510 - 515
  • [44] Effects of Media Exposure to Conflicting Information About Mammography: Results From a Population-based Survey Experiment
    Nagler, Rebekah H.
    Yzer, Marco C.
    Rothman, Alexander J.
    ANNALS OF BEHAVIORAL MEDICINE, 2019, 53 (10) : 896 - 908
  • [45] Establishing minimum performance standards, calibration intervals, and optimal exposure values for a whole breast digital mammography unit
    Kimme-Smith, C
    Lewis, C
    Beifuss, M
    Williams, MB
    Bassett, LW
    MEDICAL PHYSICS, 1998, 25 (12) : 2410 - 2416
  • [46] Comparison of radiation exposure and associated radiation-induced cancer risks from mammography and molecular imaging of the breast
    O'Connor, Michael K.
    Li, Hua
    Rhodes, Deborah J.
    Hruska, Carrie B.
    Clancy, Conor B.
    Vetter, Richard J.
    MEDICAL PHYSICS, 2010, 37 (12) : 6187 - 6198
  • [47] Radiation Exposure of Digital Breast Tomosynthesis Using an Antiscatter Grid Compared With Full-Field Digital Mammography
    Paulis, Leonie E.
    Lobbes, Marc B. I.
    Lalji, Ulrich C.
    Gelissen, Nicky
    Bouwman, Ramona W.
    Wildberger, Joachim E.
    Jeukens, Cecile R. L. P. N.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 679 - 685
  • [48] Intra-individual Comparison of Average Glandular Dose of Two Digital Mammography Units using Different Anode/Filter Combinations
    Engelken, Florian J. F.
    Meyer, Henning
    Juran, Ralf
    Bick, Ulrich
    Fallenberg, Eva
    Diekmann, Felix
    ACADEMIC RADIOLOGY, 2009, 16 (10) : 1272 - 1280
  • [49] Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography.
    Hermann, KP
    Obenauer, S
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11): : 940 - 945
  • [50] Computation of beam quality parameters for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations in mammography
    Kharrati, H
    Zarrad, B
    MEDICAL PHYSICS, 2003, 30 (10) : 2638 - 2642