Outcomes of LASIK for Myopia or Myopic Astigmatism Correction with the FS200 Femtosecond Laser and EX500 Excimer Laser Platform

被引:10
作者
Niparugs, Muanploy
Tananuvat, Napaporn
Chaidaroon, Winai
Tangmonkongvoragul, Chulaluck
Ausayakhun, Somsanguan [1 ]
机构
[1] Chiang Mai Univ, Dept Ophthalmol, Fac Med, Chiang Mai 50200, Thailand
来源
OPEN OPHTHALMOLOGY JOURNAL | 2018年 / 12卷
关键词
Laser in situ Keratomileusis (LASIK); Myopic correction; Myopic astigmatism; Femtosecond laser; Excimer laser; UDVA;
D O I
10.2174/1874364101812010063
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the efficacy, predictability, stability and safety of laser in situ keratomileusis (LASIK) using the FS200 femtosecond laser and EX500 excimer laser platform. Methods: The outcomes of 254 eyes of 129 consecutive patients with myopia or myopic astigmatism who underwent full correction femtosecond laser-assisted LASIK at CMU LASIK Center were assessed. Pre-operative and post-operative parameters including manifest refraction, Uncorrected Distance Visual Acuity (UDVA), Best Corrected Distance Visual Acuity (BDVA), corneal topography and tomography were analyzed. The results between low to moderate myopia and high myopia were compared up to 12 months. Results: Mean pre-operative Spherical Equivalent (SE) was -5.15 +/- 2.41 Diopters (D) (range -0.50 to -11.50 D) and -0.13 +/- 0.28 D, -0.13 +/- 0.27 D, -0.13 +/- 0.28 D and -0.14 +/- 0.30 D at 1, 3, 6, and 12 months, post-operatively. At 12 months, the propor notsign tion of eyes achieving UDVA >= 20/20 was 90.0% and >= 20/40 was 98.8%. The proportion of eyes achieving post-operative mean SE +/- 0.5 D, and +/- 1 D was 91.3%, and 98.5%. No eyes lost more than two lines of BDVA. The low to moderate myopic group had a statistically significant better UDVA at one (p=0.017) and three months (p=0.014) but no difference at six (p=0.061) and 12 months (p=0.091). The mean post-operative SE was better in low to moderate myopic group at every follow-up visit (p=0.001, 0.007, <0.001 and <0.001). Conclusion: One-year clinical results of LASIK with the FS200 femtosecond laser and EX500 excimer laser showed high efficacy, predictability, stability and safety.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 17 条
[1]   The evolution of corneal and refractive surgery with the femtosecond laser [J].
Aristeidou, Antonis ;
Taniguchi, Elise V. ;
Tsatsos, Michael ;
Muller, Rodrigo ;
McAlinden, Colm ;
Pineda, Roberto ;
Paschalis, Eleftherios I. .
EYE AND VISION, 2015, 2
[2]   IntraLase Femtosecond Laser vs Mechanical Microkeratomes in LASIK for Myopia: A Systematic Review and Meta-analysis [J].
Chen, Shihao ;
Feng, Yifan ;
Stojanovic, Aleksandar ;
Jankov, Mirko R., II ;
Wang, Qinmei .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (01) :15-24
[3]   Incidence of diffuse lamellar keratitis after LASIK with 15 KHz, 30 KHz, and 60 KHz femtosecond laser flap creation [J].
Choe, Christina H. ;
Guss, Carly ;
Musch, David C. ;
Niziol, Leslie M. ;
Shtein, Roni M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (11) :1912-1918
[4]   Prospective Evaluation of Outcomes in Patients Undergoing Treatment for Myopia Using the WaveLight Refractive Suite [J].
Cummings, Arthur ;
Durrie, Daniel ;
Gordon, Michael ;
Williams, Ravaughn ;
Gow, James A. ;
Maus, Matthias .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (05) :322-U91
[5]   Predictability of corneal flap thickness in laser in situ keratomileusis using a 200 kHz femtosecond laser [J].
Cummings, Arthur B. ;
Cummings, Brendan K. ;
Kelly, Gabrielle E. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03) :378-385
[6]   Inverse Cutting of Posterior Lamellar Corneal Grafts by a Femtosecond Laser [J].
Hjortdal, Jesper ;
Nielsen, Esben ;
Vestergaard, Anders ;
Sondergaard, Anders .
OPEN OPHTHALMOLOGY JOURNAL, 2012, 6 :19-22
[7]   Femtosecond lasers for laser in situ keratomileusis: a systematic review and meta-analysis [J].
Huhtala, Anne ;
Pietila, Juhani ;
Makinen, Petri ;
Uusitalo, Hannu .
CLINICAL OPHTHALMOLOGY, 2016, 10 :393-404
[8]   Long-term bladeless LASIK outcomes with the FS200 Femtosecond and EX500 Excimer Laser workstation: the Refractive Suite [J].
Kanellopoulos, A. John ;
Asimellis, George .
CLINICAL OPHTHALMOLOGY, 2013, 7 :261-268
[9]   Applications of the femtosecond laser in corneal refractive surgery [J].
Kim, Peter ;
Sutton, Gerard L. ;
Rootman, David S. .
CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (04) :238-244
[10]   Thin-flap laser in situ keratomileusis with femtosecond-laser technology [J].
Kymionis, George D. ;
Kontadakis, George A. ;
Grentzelos, Michael A. ;
Panagopoulou, Sophia I. ;
Stojanovic, Nela ;
Kankariya, Vardhaman P. ;
Henderson, Bonnie A. ;
Pallikaris, Ioannis G. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (09) :1366-1371