MICRO ENZYME-SENSOR WITH OSMIUM COMPLEX AND A POROUS CARBON FOR MEASURING URIC-ACID

被引:27
作者
MOTONAKA, J [1 ]
MIYATA, K [1 ]
FAULKNER, LR [1 ]
机构
[1] UNIV ILLINOIS,DEPT CHEM,URBANA,IL 61801
关键词
ENZYME SENSOR; URIC ACID; URICASE; OSMIUM COMPLEX; POROUS CARBON SHEET;
D O I
10.1080/00032719408006342
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micro enzyme-sensor using uricase (EC 1.7.3.3) was developed for measuring uric acid. For this, a sheet of porous composite was made from acetylene black and Teflon emulsion and was soaked in Zonyl FSN fluoro-carbon surfactant and Nafion. The 50 mu m platinum micro-electrode was etched in hot aqua regia to create a cavity at its tip and this cavity was packed with porous composite material by pushing the tip into small lumps of the material. The redox mediator [Os(bpy)(3)(PF6)(2)] was monitored by cyclic voltammetry. The porous micro-sensor was dipped overnight in Tris-hydrochloric acid buffer of pH 8.0 containing enzyme for adsorption of uricase at 4 degrees C. The effects of pH, and temperature on measurements of uric acid with the sensor were examined, the calibration curve for measurement of uric acid under optimum conditions was determined and the effect of concomitant compounds were investigated. Under optimum conditions, the response of the micro-sensor was linear in the concentration range of 0.101 - 1.93mM uric acid. The uric acid concentrations in commercial preparations and human serum were also determined with this sensor.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 34 条
[1]  
BURSTALL FH, 1950, J CHEM SOC, V111, P953
[2]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[3]   FERRICINIUM ION AS AN ELECTRON-ACCEPTOR FOR OXIDO-REDUCTASES [J].
CASS, AEG ;
DAVIS, G ;
GREEN, MJ ;
HILL, HAO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 190 (1-2) :117-127
[4]  
CHA CS, 1975, J WUHAN U, V2, P58
[5]  
CHE G, 1993, J ELECTROANAL CHEM, V386, P239
[6]   ELECTROCHEMICAL STUDY OF THE RATE OF ACTIVATION OF THE MOLYBDOHEME PROTEIN SULFITE OXIDASE BY ORGANIC ELECTRON-ACCEPTORS [J].
COURY, LA ;
LIU, Y ;
MURRAY, RW .
ANALYTICAL CHEMISTRY, 1993, 65 (03) :242-246
[7]  
CRDOSI MF, 1987, ANAL P, V24, P143
[8]   THE ELECTROCHEMISTRY OF HEXACYANORUTHENATE AT CARBON ELECTRODES AND THE USE OF RUTHENIUM COMPOUNDS AS MEDIATORS IN THE GLUCOSE GLUCOSE-OXIDASE SYSTEM [J].
CRUMBLISS, AL ;
HILL, HAO ;
PAGE, DJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 206 (1-2) :327-331
[9]   SELECTIVE DETERMINATION OF OXALATE IONS WITH A FIBEROPTIC ELECTROCHEMILUMINESCENCE SENSOR HAVING A CARBON PASTE ELECTRODE MODIFIED WITH BIS (2,2'-BIPYRIDINE)-(4,4'-DINONADECYL-2,2'-BIPYRIDINE) RUTHENIUM(II) [J].
EGASHIRA, N ;
KONDOH, N ;
KURAUCHI, Y ;
OHGA, K .
DENKI KAGAKU, 1992, 60 (12) :1148-1151
[10]  
ELMGREM M, 1992, J ELECTROANAL CHEM, V341, P85