RADIATION HARDNESS OF MOLYBDENUM SILICON MULTILAYERS DESIGNED FOR USE IN A SOFT-X-RAY PROJECTION LITHOGRAPHY SYSTEM

被引:22
作者
GAINES, DP
SPITZER, RC
CEGLIO, NM
KRUMREY, M
ULM, G
机构
[1] INST BERLIN, PHYS TECH BUNDESANSTALT, W-1000 BERLIN 10, GERMANY
[2] BRIGHAM YOUNG UNIV, PROVO, UT 84601 USA
来源
APPLIED OPTICS | 1993年 / 32卷 / 34期
关键词
D O I
10.1364/AO.32.006991
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A molybdenum silicon multilayer is irradiated with 13.4-nm radiation to investigate changes in multilayer performance under simulated soft-x-ray projection lithography (SXPL) conditions. The wiggler-undulator at the Berlin electron storage ring BESSY is used as a quasi-monochromatic source of calculable spectral radiant intensity and is configured to simulate an incident SXPL x-ray spectrum. The test multilayer receives a radiant exposure of 240 J/mm2 in an exposure lasting 8.9 h. The corresponding average incident power density is 7.5 mW/mm2. The absorbed dose of 7.8 x 10(10) J/kg (7.8 x 10(12) rad) is equivalent to 1.2 times the dose that would be absorbed by a multilayer coating on the first imaging optic in a hypothetical SXPL system during 1 year of operation. Surface temperature increases do not exceed 2-degrees-C during the exposure. Normal-incidence reflectance measurements at lambda0 = 13.4 nm performed before radiation exposure are in agreement with measurements performed after the exposure, indicating that no significant damage had occurred.
引用
收藏
页码:6991 / 6998
页数:8
相关论文
共 27 条
  • [1] CALCULATIONS OF MEAN FREE PATHS AND STOPPING POWERS OF LOW-ENERGY ELECTRONS (LESS-THAN-OR-EQUAL-TO 10 KEV) IN SOLIDS USING A STATISTICAL-MODEL
    ASHLEY, JC
    TUNG, CJ
    RITCHIE, RH
    ANDERSON, VE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (06) : 1833 - 1837
  • [2] Front-end design issues in soft-x-ray projection lithography
    Ceglio, Natale M.
    Hawryluk, Andrew M.
    Sommargren, Gary E.
    [J]. Applied Optics, 1993, 32 (34) : 7050 - 7056
  • [3] CEGLIO NM, 1991, P SOC PHOTOOPT INSTR, V1547, P82
  • [4] GAINES DP, 1991, P SOC PHOTO-OPT INS, V1547, P228
  • [5] AN UNDULATOR-MULTIPOLE WIGGLER FOR THE BESSY STORAGE RING
    GUDAT, W
    PFLUGER, J
    CHATZIPETROS, J
    PEATMAN, W
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) : 50 - 53
  • [6] 0.1-10-KEV X-RAY-INDUCED ELECTRON EMISSIONS FROM SOLIDS - MODELS AND SECONDARY-ELECTRON MEASUREMENTS
    HENKE, BL
    SMITH, JA
    ATTWOOD, DT
    [J]. JOURNAL OF APPLIED PHYSICS, 1977, 48 (05) : 1852 - 1866
  • [7] QUASI-MONOCHROMATIC SYNCHROTRON RADIATION FROM UNDULATORS
    HOFMANN, A
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1978, 152 (01): : 17 - 21
  • [8] JEWELL TE, 1991, P SOC PHOTO-OPT INS, V1527, P163, DOI 10.1117/12.48683
  • [9] STABILITY OF TUNGSTEN CARBON AND TUNGSTEN SILICON MULTILAYER X-RAY MIRRORS UNDER THERMAL ANNEALING AND X-RADIATION EXPOSURE
    KORTRIGHT, JB
    JOKSCH, S
    ZIEGLER, E
    [J]. JOURNAL OF APPLIED PHYSICS, 1991, 69 (01) : 168 - 174
  • [10] SELF-CALIBRATION OF SEMICONDUCTOR PHOTODIODES IN THE SOFT-X-RAY REGION
    KRUMREY, M
    TEGELER, E
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) : 797 - 801