A SELECTIVE AND SENSITIVE KINETIC METHOD FOR THE DETERMINATION OF PROCAINE AND BENZOCAINE IN PHARMACEUTICALS

被引:8
作者
CARMONA, M [1 ]
SILVA, M [1 ]
PEREZBENDITO, D [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
PROCAINE; BENZOCAINE; PHARMACEUTICALS; STOPPED-FLOW; SPECTROPHOTOMETRY;
D O I
10.1016/0731-7085(92)80022-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple stopped-flow method for the determination of procaine and benzocaine which is suitable for their routine analysis in pharmaceutical samples is reported. The method is based on a condensation reaction between each compound and 4-dimethylaminocinnamaldehyde, which yields coloured compounds and which are monitored spectrophotometrically. The calibration graph generated is linear over the range 0.5-20-mu-g ml-1 (RSD 0.73%) for procaine and 0.5-15-mu-g ml-1 (RSD 0.40%) for benzocaine, and the selectivity is very high in both cases. The proposed methods were satisfactorily applied to the determination of the two drugs in various pharmaceutical samples. A procedure for resolution of procaine-benzocaine mixtures in mass ratios between 15:1 and 1:7 with a precision of ca 1% was developed in order to determine one compound in the presence of the other with no interference.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 33 条
[1]  
BENDITO DP, 1988, KINETIC METHODS ANAL, pCH6
[2]  
BEZUGLYI V D, 1983, Farmatsiya (Moscow), V32, P30
[3]   AUTOMATIC STOPPED-FLOW DETERMINATION OF L-CYSTEINE [J].
CARDOSO, A ;
SILVA, M ;
PEREZBENDITO, D .
TALANTA, 1989, 36 (09) :963-965
[4]   STOPPED-FLOW KINETIC DETERMINATION OF ACETAMINOPHEN BY OXIDATION WITH A 1,10-PHENANTHROLINE-IRON(III) COMPLEX [J].
CARMONA, M ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1989, 218 (02) :313-322
[5]   SIMULTANEOUS KINETIC DETERMINATION OF EPINEPHRINE AND NOREPINEPHRINE BY THE STOPPED-FLOW TECHNIQUE [J].
CARMONA, M ;
SILVA, M ;
PEREZBENDITO, D .
ANALYST, 1991, 116 (10) :1075-1079
[6]   SPECTROPHOTOMETRIC DETERMINATION OF CERTAIN LOCAL-ANESTHETICS USING 3-METHYLBENZOTHIAZOLIN-2-ONE HYDRAZONE [J].
ELKOMMOS, ME ;
EMARA, KM .
ANALYST, 1987, 112 (09) :1253-1256
[7]   KINETIC ANALYSIS OF MIXTURES BY METHOD OF PROPORTIONAL EQUATIONS [J].
GARMON, RG ;
REILLEY, CN .
ANALYTICAL CHEMISTRY, 1962, 34 (06) :600-+
[8]   SOME OBSERVATIONS ON THE ANALYTICAL UTILITY OF A FLUOROMETRIC STOPPED-FLOW METHOD FOR RESOLUTION OF HISTIDINE AND 1-METHYLHISTIDINE MIXTURES [J].
GUTIERREZ, MC ;
GOMEZHENS, A ;
PEREZBENDITO, D .
MICROCHEMICAL JOURNAL, 1988, 38 (03) :325-331
[9]   KINETIC-PHOTOMETRIC DETERMINATION OF SPERMINE, SPERMIDINE AND THEIR MIXTURES BY THE STOPPED-FLOW TECHNIQUE [J].
GUTIERREZ, MC ;
GOMEZHENS, A ;
PEREZBENDITO, D .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (06) :642-645
[10]   MODULAR STOPPED-FLOW DIODE-ARRAY DETECTION SYSTEM FOR SIMULTANEOUS KINETIC-ANALYSIS [J].
GUTIERREZ, MC ;
GOMEZHENS, A ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1989, 225 (01) :115-122