Plasticizer Effects in the PVC Membrane of the Dibasic Phosphate Selective Electrode

被引:11
作者
Carey, Clifton [1 ]
机构
[1] Univ Colorado, Sch Dent Med, Dept Craniofacial Biol, 12800 E 19th Ave,MS 8310, Denver, CO 80206 USA
基金
美国国家卫生研究院;
关键词
ion-selective electrode; chemical sensor; phosphate; plasticizer; lipophilicity; liquid membrane; sensitivity; selectivity;
D O I
10.3390/chemosensors3040284
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The PVC membrane of an ion-selective electrode (ISE) sensitive to dibasic phosphate ions (HPO4-ISE) has not been optimized for maximum selectivity, sensitivity, and useable ISE lifetime and further work was necessary to improve its performance. Two areas of investigation are reported here: include the parameters for the lipophilicity of the plasticizer compound used and the amount of cyclic polyamine ionophore incorporated in the PVC membrane. Six candidate plasticizers with a range of lipophilicity were evaluated for their effect on the useable lifetime, sensitivity, and selectivity of the ISE against 13 different anions. Selectivity was determined by a modified fixed interferent method, sensitivity was determined without interferents, and the usable lifetime evaluated at the elapsed time where 50% of the HPO4-ISE failed (L-50). The results show that choosing a plasticizer that has a lipophilicity similar to the ionophore's results in the best selectivity and sensitivity and the longest L-50.
引用
收藏
页码:284 / 294
页数:11
相关论文
共 10 条
[1]   EFFECT OF INTERFERING ION CONCENTRATION AND METHOD OF CALCULATION ON POTENTIOMETRIC SELECTIVITY COEFFICIENTS OF CROWN ETHER BASED LIQUID MEMBRANE ION-SELECTIVE ELECTRODES [J].
ATTIYAT, AS ;
CHRISTIAN, GD .
ANALYTICAL SCIENCES, 1988, 4 (01) :13-16
[2]  
Bedlechowicz W, 2002, J ELECTROANAL CHEM, V537, P111
[3]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[4]   CYCLIC POLYAMINE IONOPHORE FOR USE IN A DIBASIC PHOSPHATE-SELECTIVE ELECTRODE [J].
CAREY, CM ;
RIGGAN, WB .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3587-3591
[5]  
Davies C.W., 1962, ION ASS, P41
[6]   LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS [J].
DINTEN, O ;
SPICHIGER, UE ;
CHANIOTAKIS, N ;
GEHRIG, P ;
RUSTERHOLZ, B ;
MORF, WE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :596-603
[7]   PLASTICIZERS FOR LIQUID POLYMERIC MEMBRANES OF ION-SELECTIVE CHEMICAL SENSORS [J].
EUGSTER, R ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
AEBERSOLD, B ;
PEDRAZZA, U ;
RUEGG, D ;
SCHMID, A ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1994, 289 (01) :1-13
[8]   Influence of different plasticizers on the response of chemical sensors based on polymeric membranes for nitrate ion determination [J].
Pérez, MD ;
Marín, LP ;
Quintana, JC ;
Yazdani-Pedram, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03) :262-268
[9]   Lipophilicity in PK design: methyl, ethyl, futile [J].
van de Waterbeemd, H ;
Smith, DA ;
Jones, BC .
JOURNAL OF COMPUTER-AIDED MOLECULAR DESIGN, 2001, 15 (03) :273-286
[10]   A comparison of neutral Mg2+-selective ionophores in solvent polymeric membranes:: Complex stoichiometry and lipophilicity [J].
Zhang, W ;
Jenny, L ;
Spichiger, UE .
ANALYTICAL SCIENCES, 2000, 16 (01) :11-18