Plasticizer Effects in the PVC Membrane of the Dibasic Phosphate Selective Electrode

被引:10
作者
Carey, Clifton [1 ]
机构
[1] Univ Colorado, Sch Dent Med, Dept Craniofacial Biol, 12800 E 19th Ave,MS 8310, Denver, CO 80206 USA
来源
CHEMOSENSORS | 2015年 / 3卷 / 04期
基金
美国国家卫生研究院;
关键词
ion-selective electrode; chemical sensor; phosphate; plasticizer; lipophilicity; liquid membrane; sensitivity; selectivity;
D O I
10.3390/chemosensors3040284
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The PVC membrane of an ion-selective electrode (ISE) sensitive to dibasic phosphate ions (HPO4-ISE) has not been optimized for maximum selectivity, sensitivity, and useable ISE lifetime and further work was necessary to improve its performance. Two areas of investigation are reported here: include the parameters for the lipophilicity of the plasticizer compound used and the amount of cyclic polyamine ionophore incorporated in the PVC membrane. Six candidate plasticizers with a range of lipophilicity were evaluated for their effect on the useable lifetime, sensitivity, and selectivity of the ISE against 13 different anions. Selectivity was determined by a modified fixed interferent method, sensitivity was determined without interferents, and the usable lifetime evaluated at the elapsed time where 50% of the HPO4-ISE failed (L-50). The results show that choosing a plasticizer that has a lipophilicity similar to the ionophore's results in the best selectivity and sensitivity and the longest L-50.
引用
收藏
页码:284 / 294
页数:11
相关论文
共 10 条
  • [1] EFFECT OF INTERFERING ION CONCENTRATION AND METHOD OF CALCULATION ON POTENTIOMETRIC SELECTIVITY COEFFICIENTS OF CROWN ETHER BASED LIQUID MEMBRANE ION-SELECTIVE ELECTRODES
    ATTIYAT, AS
    CHRISTIAN, GD
    [J]. ANALYTICAL SCIENCES, 1988, 4 (01) : 13 - 16
  • [2] Bedlechowicz W, 2002, J ELECTROANAL CHEM, V537, P111
  • [3] RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994)
    BUCK, RP
    LINDNER, E
    [J]. PURE AND APPLIED CHEMISTRY, 1994, 66 (12) : 2527 - 2536
  • [4] CYCLIC POLYAMINE IONOPHORE FOR USE IN A DIBASIC PHOSPHATE-SELECTIVE ELECTRODE
    CAREY, CM
    RIGGAN, WB
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (21) : 3587 - 3591
  • [5] Davies C.W., 1962, ION ASS, P41
  • [6] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [7] PLASTICIZERS FOR LIQUID POLYMERIC MEMBRANES OF ION-SELECTIVE CHEMICAL SENSORS
    EUGSTER, R
    ROSATZIN, T
    RUSTERHOLZ, B
    AEBERSOLD, B
    PEDRAZZA, U
    RUEGG, D
    SCHMID, A
    SPICHIGER, UE
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1994, 289 (01) : 1 - 13
  • [8] Influence of different plasticizers on the response of chemical sensors based on polymeric membranes for nitrate ion determination
    Pérez, MD
    Marín, LP
    Quintana, JC
    Yazdani-Pedram, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03): : 262 - 268
  • [9] Lipophilicity in PK design: methyl, ethyl, futile
    van de Waterbeemd, H
    Smith, DA
    Jones, BC
    [J]. JOURNAL OF COMPUTER-AIDED MOLECULAR DESIGN, 2001, 15 (03) : 273 - 286
  • [10] A comparison of neutral Mg2+-selective ionophores in solvent polymeric membranes:: Complex stoichiometry and lipophilicity
    Zhang, W
    Jenny, L
    Spichiger, UE
    [J]. ANALYTICAL SCIENCES, 2000, 16 (01) : 11 - 18