Computer aided spine surgery. What's new fifteen years later ?

被引:0
作者
Merloz, Ph [1 ]
Ruatti, S. [1 ]
Milaire, M. [1 ]
Kerschbaumer, G. [1 ]
Tonetti, J. [1 ]
机构
[1] CHU A Michallon, Clin Univ Orthopedie Traumatol, BP 217, F-38043 Grenoble 09, France
来源
E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE | 2013年 / 12卷 / 01期
关键词
Computer-assisted spine surgery; Surgical navigation; Computer-assisted orthopedic surgery; Spine surgery; Computer-assisted surgery;
D O I
10.14607/emem.2013.1.009
中图分类号
R61 [外科手术学];
学科分类号
摘要
The first navigation systems for spine surgery were introduced in the mid 90's to optimize pedicle screws insertion. Both technologies are still used: CT-based navigation and fluoronavigation (2D fluoronavigation) system which can be considered as an alternative to CT- based navigation technology. Three new technologies were introduced in the late 2000's and can be added to the orthopedic intra-operative arsenal for spine surgery. The 3D isocentric fluoroscope is a new type of fluoroscope, able to provide intra-operative CT-like images without the need of registration process. With templating technology, patient's CT data is used to simulate and plan preoperatively the pedicle screw trajectory on a computer workstation. A rapid prototyping technology provides templates that are intraoperatively attached to the back side of the spine at their appropriate position, thanks to the precise representation of the bony surface. Then, each drill can be carried out accurately, exactly where it has been planned. The small robots such as "Bone Mounted Robots" can be fixed directly within the operating field. With CT- based navigation technology, and a 3D - 2D registration process, they demonstrated their ability to help the surgeon to perform pedicle drilling with a high degree of accuracy. Meta-analyzes show that 3D fluoroscopic navigation systems are slightly more accurate than CT based and 2D fluoroscopic navigation systems. In terms of radiation dose, 3D fluoroscopic navigation seems less radiating than conventional fluoroscopy, but this remains to be proven formally. The results for a large-scale clinical use of the bone-mounted robot and templates are not yet known and their clinical application field is being to be considered.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 35 条
[1]   Computer-assisted orthopedic surgery with individual templates and comparison to conventional operation method [J].
Birnbaum, K ;
Schkommodau, E ;
Decker, N ;
Prescher, A ;
Klapper, U ;
Radermacher, K .
SPINE, 2001, 26 (04) :365-369
[2]  
Desbat L, 2002, COMPUTER AIDED MED I, P288
[3]   Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot Retrospective Study [J].
Devito, Dennis P. ;
Kaplan, Leon ;
Dietl, Rupert ;
Pfeiffer, Michael ;
Horne, Dale ;
Silberstein, Boris ;
Hardenbrook, Mitchell ;
Kiriyanthan, George ;
Barzilay, Yair ;
Bruskin, Alexander ;
Sackerer, Dieter ;
Alexandrovsky, Vitali ;
Stueer, Carsten ;
Burger, Ralf ;
Maeurer, Johannes ;
Gordon, Donald G. ;
Schoenmayr, Robert ;
Friedlander, Alon ;
Knoller, Nachshon ;
Schmieder, Kirsten ;
Pechlivanis, Ioannis ;
Kim, In-Se ;
Meyer, Bernhard ;
Shoham, Moshe .
SPINE, 2010, 35 (24) :2109-2115
[4]  
Foley K. T., 2000, OPER TECH ORTHOP, V10, P77
[5]   Computer-assisted fluoroscopic navigation of pedicle screw insertion - An in vivo feasibility study [J].
Fu, TS ;
Chen, LH ;
Wong, CB ;
Lai, PL ;
Tsai, TT ;
Niu, CC ;
Chen, WJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :730-735
[6]  
Gruetzner PA, 2004, EUR J TRAUMA, V30, P161, DOI DOI 10.1007/S00068-004-1328-6
[7]   Intraoperative three-dimensional navigation for pedicle screw placement [J].
Grützner, PA ;
Beutler, T ;
Wendl, K ;
von Recum, J ;
Wentzensen, A ;
Nolte, LP .
CHIRURG, 2004, 75 (10) :967-975
[8]   Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement [J].
Kantelhardt, Sven Rainer ;
Martinez, Ramon ;
Baerwinkel, Stefan ;
Burger, Ralf ;
Giese, Alf ;
Rohde, Veit .
EUROPEAN SPINE JOURNAL, 2011, 20 (06) :860-868
[9]   Can Computer-assisted Surgery Reduce the Effective Dose for Spinal Fusion and Sacroiliac Screw Insertion? [J].
Kraus, Michael David ;
Krischak, Gert ;
Keppler, Peter ;
Gebhard, Florian T. ;
Schuetz, Uwe H. W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) :2419-2429
[10]  
Lavallee S, 1995, J Image Guid Surg, V1, P65, DOI 10.1002/(SICI)1522-712X(1995)1:1<65::AID-IGS10>3.3.CO