Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial

被引:21
作者
Abohabib, Ahmed Mohamed [1 ]
Fayed, Mona Mohamed [2 ,3 ]
Labib, Amr H. [2 ]
机构
[1] Kafrelsheikh Univ, Fac Dent, Karfelskeikh, Egypt
[2] Cairo Univ, Fac Dent, Dept Orthodont, Cairo, Egypt
[3] Univ Malaya, Fac Dent, Dept Pediat Dent & Orthodont, Kuala Lumpur, Malaysia
关键词
Orthodontic mini-implants; mini-screws; low-intensity laser; resonance frequency analysis;
D O I
10.1080/14653125.2018.1481710
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances. Design: A split-mouth randomised clinical trial. Setting: Subjects were recruited and treated in the outpatient clinic, Department of Orthodontics, Faculty of Dentistry, Cairo University. Participants: Fifteen subjects with mean age 20.9 (+/- 3.4) years who required extraction of maxillary first premolar teeth and mini-implant-supported canine retraction. Methods: Thirty orthodontic mini-implants were inserted bilaterally in the maxillary arches of recruited subjects following alignment and levelling. Mini-implants were immediately loaded with a force of 150 g using nickel titanium coil springs with split-mouth randomisation to a low-intensity laser-treated side and control side. The experimental sides were exposed to low-intensity laser therapy from a diode laser with a wavelength of 940 nm at (0, 7, 14, 21 days) after mini-implant placement. Mini-implant stability was measured using resonance frequency analysis at (0, 1, 2, 3, 4, 6, 8, 10 weeks) after implant placement. Results: A total sample of 28 mini-implants were investigated with 14 in each group. Clinically, both mini-implant groups had the same overall success rate of 78.5%. There were no significant differences in resonance frequency scores between low-intensity laser and control sides from baseline to week 2. However, from week 3 to 10, the low-intensity laser sides showed significantly increased mean resonance frequency values compared to control (P > 0.05). Conclusions: Despite evidence of some significant differences in resonance frequency between mini-implants exposed to low-intensity laser light over a 10 weeks period there were no differences in mini-implant stability. Low-intensity laser light cannot be recommended as a clinically useful adjunct to promoting mini-implant stability during canine retraction.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 36 条
[1]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[2]   Mini-implant anchorage for the orthodontic practitioner [J].
Baumgaertel, Sebastian ;
Razavi, Mohammad R. ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (04) :621-627
[3]   Effects of pilot holes on longitudinal miniscrew stability and bony adaptation [J].
Carney, Lauren Ohlenforst ;
Campbell, Phillip M. ;
Spears, Robert ;
Ceen, Richard F. ;
Melo, Ana Claudia ;
Buschang, Peter H. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (05) :554-564
[4]   Critical factors for the success of orthodontic mini-implants: A systematic review [J].
Chen, Yan ;
Kyung, Hee Moon ;
Zhao, Wen Ting ;
Yu, Won Jae .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (03) :284-291
[5]  
Chopra S S, 2015, Med J Armed Forces India, V71, P165, DOI 10.1016/j.mjafi.2012.06.020
[6]   Biostimulation of wound healing by low-energy laser irradiation - A review [J].
Conlan, MJ ;
Rapley, JW ;
Cobb, CM .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (05) :492-496
[7]  
Fan Li, 2014, Shanghai Kou Qiang Yi Xue, V23, P614
[8]   Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography [J].
Fayed, Mona Mohamed Salah ;
Pazera, Pawel ;
Katsaros, Christos .
ANGLE ORTHODONTIST, 2010, 80 (05) :939-951
[9]   Effects of low-intensity laser therapy over mini-implants success rate in pigs [J].
Garcez, Aguinaldo S. ;
Suzuki, Selly Sayuri ;
Martinez, Elisabeth Ferreira ;
Iemini, Mylene Garcez ;
Suzuki, Hideo .
LASERS IN MEDICAL SCIENCE, 2015, 30 (02) :727-732
[10]   Histomorphometric Evaluation of the Effects of Various Diode Lasers and Force Levels on Orthodontic Mini Screw Stability [J].
Goymen, Merve ;
Isman, Eren ;
Taner, Lale ;
Kurkcu, Mehmet .
PHOTOMEDICINE AND LASER SURGERY, 2015, 33 (01) :29-34