Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures

被引:3
作者
Gogna, Paritosh [1 ]
Mukhopadhyay, Reetadyuti [1 ]
Singh, Amanpreet [1 ]
Devgan, Ashish [1 ]
Arora, Sahil [1 ]
Batra, Amit [1 ]
Yadav, Sushil Kumar [1 ]
机构
[1] Pt BD Sharma Postgrad Inst Med Sci, Dept Orthopaed & Rehabil, Rohtak, Haryana, India
关键词
Femoral fractures; Bone plates; Fracture fixation;
D O I
10.1016/j.cjtee.2015.11.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Subtrochanteric fractures of the femur are being managed successfully with various intramedullary and extramedulary implants with reasonable success. However, these implants require precise placement under image intensifier guidance, which exposes the surgeon to substantial amount of radiation. It also restricts the management of these fractures at peripheral centers where facility of image intensifiers is not available. Keeping this in mind we designed this study to identify if contralateral reversed distal femoral locking plate can be used successfully without the use of image intensifier. Methods: Twenty-four consecutive patients (18 men and 6 women) with a mean age of 28 years (range 19-47 years) suffering subtrochanteric fractures of the femur underwent open reduction and internal fixation with reversed contralateral distal femoral locking plate. The outcome was assessed at the mean follow-up period of 3.2 years (range 2-4.6 years) using the Harris hip score. Results: Twenty-one fractures united with the primary procedure, with a mean time of consolidation being 11 weeks (range, 9-16 weeks). One patient developed superficial suture line infection, which resolved with oral antibiotics. Another patient had a fall 3 weeks after surgery and broke the plate. Repeat surgery with reversed distal femoral locking compression plate was performed along with bone grafting and the fracture united. Two cases had nonunion, which went in for union after bone grafting. The mean Harris hip score at the time of final follow-up was 90.63 (range 82-97). Conclusion: The reversed contralateral distal femoral plate is a biomechanically sound implant, which when used for fixation of the subtrochanteric fractures with minimal soft tissue stripping shows results comparable to those achieved by using other extramedullary implants as well as intramedullary devices. The added advantage of this implant is its usability in the absence of an image intensifier. (C) 2015 The Authors. Production and hosting by Elsevier B.V. on behalf of Daping Hospital and the Research Institute of Surgery of the Third Military Medical University.
引用
收藏
页码:279 / 283
页数:5
相关论文
共 20 条
[11]   Evolution of the internal fixation of long bone fractures - The scientific basis of biological internal fixation: Choosing a new balance between stability and biology [J].
Perren, SM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08) :1093-1110
[12]   Intramedullary fixation of high subtrochanteric femoral fractures: A study comparing two implant designs, the Gamma nail and the intramedullary hip screw [J].
Rantanen, J ;
Aro, HT .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (04) :249-252
[13]  
Rohilla R, 2008, J Orthop Surg (Hong Kong), V16, P150
[14]   Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures [J].
Siebenrock, KA ;
Müller, U ;
Ganz, R .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 :7-15
[15]   Cephalomedullary nails in the treatment of high-energy proximal femur fractures in young patients: A prospective, randomized comparison of trochanteric versus piriformis fossa entry portal [J].
Starr, AJ ;
Hay, MT ;
Reinert, CM ;
Borer, DS ;
Christensen, KC .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (04) :240-246
[16]   Are there advances in the treatment of extracapsular hip fractures in the elderly? [J].
Stern, Richard .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 :77-87
[17]  
TENCER A F, 1984, Journal of Orthopaedic Research, V2, P297, DOI 10.1002/jor.1100020312
[18]   The use of a dynamic condylar screw and biological reduction techniques for subtrochanteric femur fracture [J].
Vaidya, SV ;
Dholakia, DB ;
Chatterjee, A .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 (02) :123-128
[19]   Condylar plate fixation of subtrochanteric femoral fractures [J].
vanMeeteren, MC ;
vanRiet, YEA ;
Roukema, JA ;
vanderWerken, C .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (10) :715-717
[20]   Treatment of unstable peritrochanteric femoral fractures using a 95° angled blade plate [J].
Yoo, MC ;
Cho, YJ ;
Kim, KI ;
Khairuddin, M ;
Chun, YS .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (10) :687-692