APPLICATION OF FRAMELESS STEREOTAXY TO PEDICLE SCREW FIXATION OF THE SPINE

被引:156
作者
KALFAS, IH
KORMOS, DW
MURPHY, MA
MCKENZIE, RL
BARNETT, GH
BELL, GR
STEINER, CP
TRIMBLE, MB
WEISENBERGER, JP
机构
[1] CLEVELAND CLIN FDN,DEPT ORTHOPED SURG,CLEVELAND,OH 44195
[2] PICKER INT,HIGHLAND HTS,OH
关键词
SPINE; STEREOTAXIS; OPERATIVE TECHNIQUE; PEDICLE FIXATION;
D O I
10.3171/jns.1995.83.4.0641
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Interactive frameless stereotaxy has been successfully applied to intracranial surgery. It has contributed to the improved localization of deep-seated brain lesions and has demonstrated a potential for reducing both operative time and morbidity. However, it has not been as effectively applied to spinal surgery. The authors describe the application of frameless stereotactic techniques to spinal surgery, specifically pedicle screw fixation of the lumbosacral spine. Preoperative axial computerized tomography (CT) images of the appropriate spinal segments are obtained and loaded onto a high-speed graphics supercomputer workstation. Intraoperatively, these images can be linked to the appropriate spinal anatomy by a sonic localization digitizer device that is interfaced with the computer workstation. This permits the surgeon to place a pointing device (sonic wand) on any exposed spinal bone landmark in the operative field and obtain multiplanar reconstructed CT images projected in near-real time on the workstation screen. The images can be manipulated to assist the surgeon in determining the proper entry point for a pedicle screw as well as defining the appropriate trajectory in the axial and sagittal planes. It can also define the correct screw length and diameter for each pedicle to be instrumented. The authors applied this device to the insertion of 150 screws into the lumbosacral spines of 30 patients. One hundred forty-nine screws were assessed to be satisfactorily placed by postoperative CT and plain film radiography. In this report the authors discuss their use of this device in the clinical setting and review their preliminary results of frameless stereotaxy applied to spinal surgery. On the basis of their findings, the authors conclude that frameless stereotactic technology can be successfully applied to spinal surgery.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 17 条
  • [1] USE OF A FRAMELESS, ARMLESS STEREOTAXIC WAND FOR BRAIN-TUMOR LOCALIZATION WITH 2-DIMENSIONAL AND 3-DIMENSIONAL NEUROIMAGING
    BARNETT, GH
    KORMOS, DW
    STEINER, CP
    WEISENBERGER, J
    [J]. NEUROSURGERY, 1993, 33 (04) : 674 - 678
  • [2] INTRAOPERATIVE LOCALIZATION USING AN ARMLESS, FRAMELESS STEREOTAXIC WAND - TECHNICAL NOTE
    BARNETT, GH
    KORMOS, DW
    STEINER, CP
    WEISENBERGER, J
    [J]. JOURNAL OF NEUROSURGERY, 1993, 78 (03) : 510 - 514
  • [3] EXTRACRANIAL APPLICATION OF THE FRAMELESS STEREOTAXIC OPERATING MICROSCOPE - EXPERIENCE WITH LUMBAR SPINE
    BRODWATER, BK
    ROBERTS, DW
    NAKAJIMA, T
    FRIETS, EM
    STROHBEHN, JW
    KELLY, PJ
    FRIEDMAN, WA
    [J]. NEUROSURGERY, 1993, 32 (02) : 209 - 213
  • [4] METHOD FOR DETERMINING VERTEBRAL BODY POSITIONS IN THE SAGITTAL PLANE USING SKIN MARKERS
    BRYANT, JT
    REID, JG
    SMITH, BL
    STEVENSON, JM
    [J]. SPINE, 1989, 14 (03) : 258 - 265
  • [5] DOHRMANN GJ, 1982, SURG NEUROL, V418, P395
  • [6] HOLE PREPARATION TECHNIQUES FOR TRANSPEDICLE SCREWS - EFFECT ON PULL-OUT STRENGTH FROM HUMAN CADAVERIC VERTEBRAE
    GEORGE, DC
    KRAG, MH
    JOHNSON, CC
    VANHAL, ME
    HAUGH, LD
    GROBLER, LJ
    [J]. SPINE, 1991, 16 (02) : 181 - 184
  • [7] ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO
    GERTZBEIN, SD
    ROBBINS, SE
    [J]. SPINE, 1990, 15 (01) : 11 - 14
  • [8] GUTHRIE BL, 1992, CLIN NEUR, V38, P112
  • [9] Murphy M A, 1994, J Clin Neurosci, V1, P38, DOI 10.1016/0967-5868(94)90066-3
  • [10] SONIC STEREOMETRY IN MICROSURGICAL PROCEDURES FOR DEEP-SEATED BRAIN-TUMORS AND VASCULAR MALFORMATIONS
    REINHARDT, HF
    HORSTMANN, GA
    GRATZL, O
    [J]. NEUROSURGERY, 1993, 32 (01) : 51 - 57