NORMOCAPNIC ANESTHESIA FOR INTRA-OCULAR SURGERY

被引:26
作者
ADAMS, AP [1 ]
FREEDMAN, A [1 ]
HENVILLE, JD [1 ]
机构
[1] OXFORD EYE HOSP, OXFORD, ENGLAND
关键词
D O I
10.1136/bjo.63.3.204
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Measurement of intraocular pressure (IOP) by applanation tonometry in 23 patients undergoing lens extraction showed that a normocapnic general anaesthetic technique with controlled ventilation of the lungs (IPPV) reliably reduced the IOP by 50% for the duration of the operative period. This was not associated with large falls in systemic arterial pressure which are often a feature of spontaneously breathing halothane anaesthesia for eye surgery. Normocapnia and IPPV were easy to achieve by use of the single-limb coaxial Bain anaesthetic breathing circuit in conjunction with an electrically driven, small, and inexpensive ventilator while the anaesthetic mixture of 33% oxygen and 0.5 halothane in nitrous oxide was delivered at a rate of 70 ml/kg body weight per minute.
引用
收藏
页码:204 / 210
页数:7