PERFORMANCE OF A BEAM TELESCOPE USING DOUBLE-SIDED SILICON MICROSTRIP DETECTORS

被引:4
作者
FISCHER, P
HAMMARSTROM, R
MENKE, S
RAITH, B
RUNOLFSSON, O
WERMES, N
机构
[1] UNIV BONN,INST PHYS,W-5300 BONN,GERMANY
[2] CERN,GENEVA,SWITZERLAND
关键词
D O I
10.1016/0168-9002(95)00489-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A beam telescope consisting of four double sided, DC coupled microstrip detectors with VLSI readout electronics has been built and tested in a 70 GeV mu(-) beam at CERN, A signal-to-noise ratio of 53:1 and a spatial resolution of 2.7 mu m (junction side) and 4.8 mu m (ohmic side) have been observed on the best detectors, A telescope performance for a particle track of sigma(xy) = 2-3 mu m and sigma(slope) = 2-3 mu rad on the front face of a test object was achieved.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 20 条
[1]  
ACCIARRI M, 1994, CERN PPE94122
[2]   THE OPAL SILICON STRIP MICROVERTEX DETECTOR WITH 2 COORDINATE READOUT [J].
ALLPORT, PP ;
BATLEY, JR ;
BECK, GA ;
CARTER, AA ;
CARTER, JR ;
DEJONG, SJ ;
SILVA, EDE ;
DUBOSCQ, JE ;
DUNWOODY, UC ;
GIBSON, V ;
GLESSING, W ;
GOLDEY, PR ;
GOODRICK, MJ ;
HAMMARSTROM, R ;
HANSON, GG ;
HONMA, AK ;
HUMBERT, R ;
JACOB, F ;
JIMENEZ, M ;
KOETKE, DS ;
KRAL, JF ;
KYBERD, P ;
LAUBER, JA ;
LEROY, C ;
MARTIN, AJ ;
MARTIN, JP ;
MIR, R ;
MOISAN, C ;
PETRY, D ;
PRITCHARD, TW ;
RUNOLFSSON, O ;
RUST, DR ;
SELLER, P ;
SHEARS, TG ;
VOILLAT, D ;
YURKO, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (03) :476-495
[3]  
ANDERSON B, 1994, IEEE T NUCL SCI, V41, P854
[4]  
BAILEY R, 1984, NUCL INSTR METH A, V226
[5]  
Batignani G., 1991, Nuclear Physics B, Proceedings Supplements, V23A, P291, DOI 10.1016/0920-5632(91)90060-R
[6]   CHARGE COLLECTION IN SILICON STRIP DETECTORS [J].
BELAU, E ;
KLANNER, R ;
LUTZ, G ;
NEUGEBAUER, E ;
SEEBRUNNER, HJ ;
WYLIE, A ;
BOHRINGER, T ;
HUBBELING, L ;
WEILHAMMER, P ;
KEMMER, J ;
KOTZ, U ;
RIEBESELL, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3) :253-260
[7]   THE DELPHI MICROVERTEX DETECTOR [J].
BINGEFORS, N ;
BORNER, H ;
BOULTER, R ;
CACCIA, M ;
CHABAUD, V ;
DIJKSTRA, H ;
EEROLA, P ;
GROSS, E ;
HORISBERGER, R ;
HUBBELING, L ;
HYAMS, B ;
KARLSSON, M ;
MAEHLUM, G ;
RATZ, K ;
RODITI, I ;
STRAVER, J ;
TRISCHUK, W ;
WEILHAMMER, P ;
DUFOUR, Y ;
BRUCKMAN, P ;
JALOCHA, P ;
KAPUSTA, P ;
TURALA, M ;
ZALEWSKA, A ;
LINDGREN, J ;
ORAVA, R ;
OSTERBERG, K ;
RONNQVIST, C ;
SAARIKKO, H ;
SAARIKKO, JP ;
TUUVA, T ;
DALMAGNE, B ;
BAMBADE, P ;
COUCHOT, F ;
FULDA, F ;
AMERY, A ;
BOOTH, PSL ;
CAMPION, AR ;
MCNULTY, R ;
SMITH, NA ;
ANDREAZZA, A ;
BATTAGLIA, M ;
BIFFI, P ;
BONVICINI, V ;
KUCEWICZ, W ;
MERONI, C ;
REDAELLI, N ;
STOCCHI, A ;
TRONCON, C ;
VEGNI, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 328 (03) :447-471
[8]  
BRENNER R, 1992, 6TH P EUR S SEM DET
[9]  
CARIA M, 1994, INFNAE9405
[10]  
DULINSKI W, 1992, LEPSI DEV STRASBOURG