FLOW INJECTION-FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF TRACE LEVELS OF CADMIUM WITH ONLINE PRECONCENTRATION BY MEANS OF COPRECIPITATION

被引:0
作者
MIN, RW [1 ]
HANSEN, EH [1 ]
机构
[1] TECH UNIV DENMARK,DEPT CHEM A,DK-2800 LYNGBY,DENMARK
关键词
TRACE METAL ANALYSIS; ONLINE PRECONCENTRATION BY COPRECIPITATION IN KNOTTED REACTOR; ELUTION BY ORGANIC SOLVENT; FLAME AAS; FLOW INJECTION; ASSAY OF CADMIUM;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection systems for determination of trace metal ions are described, which comprize on-line preconcentration by coprecipitation with ensuing dissolution and detection by flame atomic absorption spectrometry. Exemplified for the assay of cadmium, which is coprecipitated with iron(II) by means of hexamethylene ammonium hexamethylene dithiocarbamate in an incorporated knotted reactor and subsequently eluted by an organic solvent of methyl isobutyl ketone, two optional FI-approaches for accomplishing this feat are compared and discussed in respect to performance. While one, which is based on a previously published procedure, employs continuous pumping of the eluting agent, the approach suggested herein relies on dissolution of the collected precipitate within a small, discrete organic zone. Because the concentration of analyte thus is increased in the eluent, this concept allows an increased sensitivity, a lower limit of detection (0.074 mu g l(-1); 3 sigma), and an extended dynamic measuring range (0.5-20 mu g l(-1)), albeit implying an increased sample consumption per assay and hence a decreased sampling frequency.
引用
收藏
页码:361 / 371
页数:11
相关论文
共 50 条
[21]   DETERMINATION OF COPPER IN WATER AND RICE SAMPLES BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION ONLINE ADSORPTION PRECONCENTRATION USING A KNOTTED REACTOR [J].
CHEN, HW ;
XU, SK ;
FANG, ZL .
ANALYTICA CHIMICA ACTA, 1994, 298 (02) :167-173
[22]   CONTINUOUS FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRIC METHOD FOR THE DETERMINATION OF ONDANSETRON [J].
ZAMORA, LL ;
CALATAYUD, JM .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :143-148
[23]   USE OF MASKING AGENTS IN THE DETERMINATION OF LEAD IN TAP WATER BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION PRECONCENTRATION [J].
BYSOUTH, SR ;
TYSON, JF ;
STOCKWELL, PB .
ANALYST, 1990, 115 (05) :571-573
[24]   Determination of trace gold by flow injection on-line preconcentration flame atomic absorption spectrometry with trioctylamine levextrel resin [J].
Ye, MD ;
Lin, MJ .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (10) :1270-1272
[25]   Preconcentration and determination of trace metals by flow injection micelle-mediated extraction using flame atomic absorption spectrometry [J].
Kara, Derya .
TALANTA, 2009, 79 (02) :429-435
[26]   DETERMINATION OF CADMIUM, COPPER AND LEAD IN ENVIRONMENTAL-SAMPLES - AN EVALUATION OF FLOW-INJECTION ONLINE SORBENT EXTRACTION FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
MA, RL ;
VANMOL, W ;
ADAMS, F .
ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) :33-43
[27]   Flow injection wetting-film extraction system for flame atomic absorption spectrometric determination of cadmium in environmental waters [J].
Adam, Ibrahim S. I. ;
Anthemidis, Aristidis N. .
TALANTA, 2009, 77 (03) :1160-1164
[28]   Flow injection on-line hydrophobic sorbent extraction for flame atomic absorption spectrometric determination of cadmium in water samples [J].
Anthemidis, Aristidis N. ;
Karapatouchas, Christos-Paraskevas P. .
MICROCHIMICA ACTA, 2008, 160 (04) :455-460
[29]   ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION USING A MULTIPURPOSE DIALYZER IN A FLOW-INJECTION SYSTEM [J].
VANSTADEN, JF ;
HATTINGH, CJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (10) :727-732
[30]   DETERMINATION OF TRACE-METALS IN NATURAL-WATERS BY FLAME ATOMIC-ABSORPTION SPECTROMETRY FOLLOWING ONLINE ION-EXCHANGE PRECONCENTRATION [J].
YEBRABIURRUN, MC ;
BERMEJOBARRERA, A ;
BERMEJOBARRERA, MP ;
BARCIELAALONSO, MC .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :341-345