A SUBMERSIBLE FLOW-INJECTION ANALYZER FOR THE IN-SITU DETERMINATION OF NITRITE AND NITRATE IN COASTAL WATERS

被引:34
作者
DANIEL, A
BIROT, D
BLAIN, S
TREGUER, P
LEILDE, B
MENUT, E
机构
[1] IFREMER,CTR BREST,INSTRUMENTAT OCEANOG LAB,F-29280 PLOUZANE,FRANCE
[2] UNIV BRETAGNE OCCIDENTALE,INST UNIV EUROPEEN MER,CNRS,URA 1513,F-29285 BREST,FRANCE
关键词
D O I
10.1016/0304-4203(95)00052-S
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An flow-injection system is described for the in-situ determination of nutrient concentrations in rivers and ocean waters. In estuarine and coastal waters, significant interferences may be caused by temperature and salinity variations. Therefore, we used a dual wavelength detector to measure simultaneously the reference and sample signals. The device has been used to measure spatial and temporal variations of nitrite and nitrate concentrations in coastal waters exhibiting strong salinity variations (Bay of Brest and Iroise Sea, France). Our original detection system coupled with flow-injection analysis (FIA) allows high-frequency measurements (40 samples per hour), very good precision (1%) and a low detection limit (0.45 mu M NO3). The device can work up to a depth of 300 m, within a temperature range of 2 to 35 degrees C, and with salinities varying from 0 to 35. The dynamic range (0-150 mu M NO3) can be adapted to the expected concentrations of the study area by using flow cells with various path lengths. Intercalibration with samples collected by conventional means and analysed with a spectrophotometric reference method at the laboratory showed a good agreement between both methods (1.3%).
引用
收藏
页码:67 / 77
页数:11
相关论文
共 25 条
[1]   AUTOCLAVED SEA-WATER AS A REFERENCE MATERIAL FOR THE DETERMINATION OF NITRATE AND PHOSPHATE IN SEA-WATER [J].
AMINOT, A ;
KEROUEL, R .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :277-283
[2]  
AMINOT A, 1983, MANUEL ANAL CHIMIQUE, P95
[3]  
Benschneider K., 1952, J MAR RES, V11, P87
[4]  
BERNHARD M, 1966, 1965 TECHN S AUT AN, P255
[5]  
BERNHARD M, 1967, AUTOMAT ANAL CHEM, P391
[6]  
BETTERIDGE D, 1978, ANALYST, V103, P897, DOI 10.1039/an9780300897
[7]  
BREWER P. G., 1965, DEEP SEA RES, V12, P765, DOI 10.1016/0011-7471(65)90797-7
[8]   SPECTROPHOTOMETRIC DETERMINATION OF DISSOLVED MANGANESE IN NATURAL-WATERS WITH 1-(2-PYRIDYLAZO)-2-NAPHTHOL - APPLICATION TO ANALYSIS IN SITU IN HYDROTHERMAL PLUMES [J].
CHIN, CS ;
JOHNSON, KS ;
COALE, KH .
MARINE CHEMISTRY, 1992, 37 (1-2) :65-82
[9]   AN AUTOMATED SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - DETERMINATION OF NITRATE [J].
CLINCH, JR ;
WORSFOLD, PJ ;
CASEY, H .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :523-531
[10]   INSITU CHEMICAL MAPPING OF DISSOLVED IRON AND MANGANESE IN HYDROTHERMAL PLUMES [J].
COALE, KH ;
CHIN, CS ;
MASSOTH, GJ ;
JOHNSON, KS ;
BAKER, ET .
NATURE, 1991, 352 (6333) :325-328