ERRORS IN ESTIMATING PERITONEAL-FLUID BY BIOELECTRICAL IMPEDANCE ANALYSIS AND TOTAL-BODY ELECTRICAL-CONDUCTIVITY

被引:1
作者
RALLISON, LR
KUSHNER, RF
PENN, D
SCHOELLER, DA
机构
[1] UNIV CHICAGO,CIENCIAS BASICAS & FARMACEUT RES UNIT,5841 S MARYLAND AVE,CHICAGO,IL 60637
[2] UNIV CHICAGO,DEPT PEDIAT,CHICAGO,IL 60637
[3] CHILDRENS HOSP,PHOENIX,AZ
关键词
BIOELECTRICAL IMPEDANCE ANALYSIS; TOTAL BODY ELECTRICAL CONDUCTIVITY; TOTAL BODY WATER;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Whole-body bioelectrical impedance analysis (BIA) and total body electrical conductivity (TOBEC) have been used to estimate body composition and generalized changes in total body water (TBW). The sensitivity of these methods to measure small, rapid, localized changes in body water has not been fully evaluated. We compared the prediction of TBW by whole-body and segmental BIA and TOBEC with deuterium oxide dilution (D2O) in 10 control subjects and 7 renal failure patients receiving continuous ambulatory peritoneal dialysis (CAPD) prior to and after dialysate infusion. Using D2O as the reference method, there was no significant mean residual error between TBW predicted by BIA and TOBEC in controls (-1.2 +/- 1.5 and -0.9 +/- 1.0 kg) and CAPD patients pre-infusion (-1.0 +/- 2.0 and 0.29 +/- 2.01 kg). After infusing 1.9 +/- 0.18 kg dialysate, the mean residual error between change in body weight and the three methods was -0.44 +/- 0.53 kg for D2O (P < 0.1), -1.7 +/- 0.25 kg for BIA (p < 0.0001), and 1.2 +/- 0.4 kg for TOBEC (p < 0.001). Segmental BIA detected a 7.6% reduction in trunkal resistance with no significant change across the limbs, consistent with abdominal fluid accumulation. It is concluded that whole-body BIA underpredicts and TOBEC overpredicts small changes in peritoneal fluids.
引用
收藏
页码:66 / 72
页数:7
相关论文
共 21 条
  • [1] ESTIMATION OF BODY-COMPOSITION FROM BIOELECTRIC IMPEDANCE OF BODY SEGMENTS
    BAUMGARTNER, RN
    CHUMLEA, WC
    ROCHE, AF
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 50 (02) : 221 - 226
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] BOHM D, 1990, INFUSIONSTHERAPIE, V17, P75
  • [4] TOTAL-BODY WATER ESTIMATED BY MEASURING TOTAL-BODY ELECTRICAL-CONDUCTIVITY
    COCHRAN, WJ
    WONG, WW
    FIOROTTO, ML
    SHENG, HP
    KLEIN, PD
    KLISH, WJ
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (04) : 946 - 950
  • [5] RELIABILITY OF FAT-FREE MASS ESTIMATES DERIVED FROM TOTAL-BODY ELECTRICAL-CONDUCTIVITY MEASUREMENTS AS INFLUENCED BY CHANGES IN EXTRACELLULAR FLUID VOLUME
    COCHRAN, WJ
    FIOROTTO, ML
    SHENG, HP
    KLISH, WJ
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 49 (01) : 29 - 32
  • [6] FIELD USE OF D218O TO MEASURE ENERGY-EXPENDITURE OF SOLDIERS AT DIFFERENT ENERGY INTAKES
    DELANY, JP
    SCHOELLER, DA
    HOYT, RW
    ASKEW, EW
    SHARP, MA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (05) : 1922 - 1929
  • [7] FALLER IL, 1955, J LAB CLIN MED, V45, P748
  • [8] FULLER NJ, 1989, EUR J CLIN NUTR, V43, P779
  • [9] BIOELECTRIC IMPEDANCE ANALYSIS - EXPERIENCE WITH MALE-PATIENTS WITH CIRRHOSIS
    GUGLIELMI, FW
    CONTENTO, F
    LADDAGA, L
    PANELLA, C
    FRANCAVILLA, A
    [J]. HEPATOLOGY, 1991, 13 (05) : 892 - 895
  • [10] HURST WW, 1952, J LAB CLIN MED, V39, P36