ADDITIONAL LOSSES IN CONVERTER-FED UNCOMPENSATED DC MOTORS - THEIR CALCULATION AND MEASUREMENT

被引:1
作者
BINDER, A
机构
[1] Fa. Siemens, EWN, Bad Neustadt/Saale, W-8740
来源
ARCHIV FUR ELEKTROTECHNIK | 1991年 / 74卷 / 05期
关键词
D O I
10.1007/BF01574124
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To raise further the ratio of output power vs. motor mass of modern d.c. motors it is necessary to reduce the additional losses effectively. Different well known analytical calculation methods for the additional losses at no-load and load are compared, concerning an accurate prediction of the additional losses. The methods for measuring additional losses are discussed, and results that are obtained with four test motors are presented. Measures to reduce the additional losses are examined both by calculation and measurement.