HIGH-RESOLUTION GAMMA-RAY SPECTROMETRY LOGGING FOR CONTAMINATION ASSESSMENT

被引:0
|
作者
KOIZUMI, CJ [1 ]
BRODEUR, JR [1 ]
PRICE, RK [1 ]
MEISNER, JE [1 ]
STROMSWOLD, DC [1 ]
机构
[1] WESTINGHOUSE HANFORD CO,RICHLAND,WA 99352
来源
NUCLEAR GEOPHYSICS | 1994年 / 8卷 / 02期
关键词
D O I
暂无
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A well-logging system containing a high-purity germanium (HPGe) detector provides quantitative assessment of gamma-ray-emitting contaminants and natural radionuclides in the subsurface. The system is in operation at the Hanford Site of the U.S. Department of Energy where radionuclide-laden effluent from the production of nuclear materials in the past has contaminated the soil. The system is calibrated by using standard formations that have known concentrations of K, U and Th. This produces calibration constants for K, U and Th, and a detector inverse efficiency function for the energy range 0.1-3 MeV. The inverse efficiency function, along with a knowledge of the energies and gamma-ray production coefficients for artificial radionuclides, allows the system to be calibrated for these artificial gamma-ray sources, even though they are not contained in the calibration standards. Corrections for a steel borehole casing and the diameter of a water-filled borehole are also derived from measurements with the calibration standards. The borehole logging measurements provide concentrations (activity per gram of earth material) of the following isotopes: K-40, Ra-226 (via Bi-214), U-238 (via Pa-234m), U-235, Th-232 (via Tl-208), Co-60, Sb-125, Cs-137, Eu-152, Eu-154, Np-237 (via Pa-233), Pu-239, Pu-240 and Am-241.
引用
收藏
页码:149 / 164
页数:16
相关论文
共 50 条
  • [31] GAMMA-RAY LOGGING
    WAHL, JS
    GEOPHYSICS, 1983, 48 (11) : 1536 - 1550
  • [32] A THERMAL HIGH-RESOLUTION ALPHA-RAY AND GAMMA-RAY SPECTROMETER
    ALESSANDRELLO, A
    BROFFERIO, C
    CAMIN, DV
    CREMONESI, O
    FIORINI, E
    GERVASIO, G
    GIULIANI, A
    PAVAN, M
    PESSINA, G
    PREVITALI, E
    ZANOTTI, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2): : 388 - 392
  • [33] Determination of primordial radionuclide concentrations in UAE groundwater using high-resolution gamma-ray spectrometry
    Rahaf Ajaj
    Nasser Shubyar
    Yazeed Alashban
    Samar El-Sayed
    Tamar Salah
    Mohammed A. Salem Al Yafei
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 330 : 923 - 928
  • [34] APPLICATION OF HIGH-RESOLUTION GAMMA-RAY SPECTROMETRY IN MEASURING RADIOACTIVITIES IN DRINKS IN HONG-KONG
    YU, KN
    MAO, SY
    APPLIED RADIATION AND ISOTOPES, 1994, 45 (10) : 1031 - 1034
  • [35] Determination of the natural radioactivity in Qatarian building materials using high-resolution gamma-ray spectrometry
    Al-Sulaiti, Huda
    Alkhomashi, N.
    Al-Dahan, N.
    Al-Dosari, M.
    Bradley, D. A.
    Bukhari, S.
    Matthews, M.
    Regan, P. H.
    Santawamaitre, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 915 - 919
  • [36] Determination of primordial radionuclide concentrations in UAE groundwater using high-resolution gamma-ray spectrometry
    Ajaj, Rahaf
    Shubyar, Nasser
    Alashban, Yazeed
    El-Sayed, Samar
    Salah, Tamar
    Al Yafei, Mohammed A. Salem
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 330 (03) : 923 - 928
  • [37] A HIGH-RESOLUTION GAMMA-RAY SPECTROMETER FOR USE IN OUTER SPACE
    MARSHALL, JH
    HALPERN, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (01) : 242 - &
  • [38] MULTIDIMENSIONAL-ANALYSIS OF HIGH-RESOLUTION GAMMA-RAY DATA
    FLIBOTTE, S
    HUTTMEIER, UJ
    BEDNARCZYK, P
    DEFRANCE, G
    HAAS, B
    ROMAIN, P
    THEISEN, C
    VIVIEN, JP
    ZEN, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2): : 325 - 330
  • [39] HIGH-RESOLUTION GAMMA-RAY SPECTROSCOPY WITH CDTE DETECTOR SYSTEMS
    RICHTER, M
    SIFFERT, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 529 - 537
  • [40] WEAK PEAK PROBLEM IN HIGH-RESOLUTION GAMMA-RAY SPECTROSCOPY
    YADAV, JS
    BRUCKNER, J
    ARNOLD, JR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3): : 591 - 598