BLOOD-PRESSURE MEASUREMENT DURING TRANSPORT - A COMPARISON OF DIRECT AND OSCILLOTONOMETRIC READINGS IN CRITICALLY ILL PATIENTS

被引:33
作者
RUNCIE, CJ [1 ]
REEVE, WG [1 ]
REIDY, J [1 ]
DOUGALL, JR [1 ]
机构
[1] WESTERN INFIRM & ASSOCIATED HOSP,DEPT ANAESTHESIA,GLASGOW G11 6NT,SCOTLAND
关键词
Blood pressure; measurement; Measurement techniques; pressure transducer; oscillotonometry;
D O I
10.1111/j.1365-2044.1990.tb14393.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study assessed the accuracy of oscillotonometric blood pressure measurement in critically ill patients during transfer. Direct intra‐arterial pressure measurements were taken in 44 transported patients as a ‘gold standard’ and compared with readings from four portable automatic oscillotonometers—the Dinamap 8100, Lifestat 100, Propaq 102 and Takeda UA711. All under‐read systolic pressure (by 13%, 21%, 19% and 13% respectively) and over‐read diastolic pressure (by 15%, 5%, 27% and 15% respectively) in comparison to direct pressure measurement. The limits of agreement for 95% of comparisons were broad. The systematic difference between direct and oscillotonometric measurements and the variability between and within patients show that direct oscillotonometric measurements are not interchangeable in these patients. Portable automatic oscillotonometers should not be substituted for direct monitoring in such circumstances. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:659 / 665
页数:7
相关论文
共 26 条
[1]   COMPARISON OF DIRECT BLOOD-PRESSURE MEASUREMENTS AT THE RADIAL AND DORSALIS PEDIS ARTERIES DURING SODIUM NITROPRUSSIDE-INDUCED AND ISOFLURANE-INDUCED HYPOTENSION [J].
ABOUMADI, M ;
LENIS, S ;
ARCHER, D ;
RAVUSSIN, P ;
TROP, D .
ANESTHESIOLOGY, 1986, 65 (06) :692-695
[2]   MEASUREMENT OF ARTERIAL-PRESSURE USING CATHETER TRANSDUCER SYSTEMS - IMPROVEMENT USING THE ACCUDYNAMIC [J].
ALLAN, MWB ;
GRAY, WM ;
ASBURY, AJ .
BRITISH JOURNAL OF ANAESTHESIA, 1988, 60 (04) :413-418
[3]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[4]   INTRA-ARTERIAL BLOOD PRESSURE DURING EXERCISE WITH DIFFERENT MUSCLE GROUPS [J].
ASTRAND, PO ;
EKBLOM, B ;
MESSIN, R ;
SALTIN, B ;
STENBERG, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (02) :253-+
[5]   TRANSPORTING CRITICALLY ILL PATIENTS BY AMBULANCE - AUDIT BY SICKNESS SCORING [J].
BION, JF ;
WILSON, IH ;
TAYLOR, PA .
BRITISH MEDICAL JOURNAL, 1988, 296 (6616) :170-170
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[8]  
GENTLEMAN D, 1981, LANCET, V2, P853
[9]   BILATERAL SIMULTANEOUS INDIRECT SYSTOLIC BLOOD-PRESSURE MEASUREMENTS [J].
GOLDHILL, DR .
CARDIOVASCULAR RESEARCH, 1986, 20 (10) :774-777
[10]   OSCILLOMETRY AND DIRECT BLOOD-PRESSURE - A COMPARATIVE CLINICAL-STUDY DURING DELIBERATE HYPOTENSION [J].
GOURDEAU, M ;
MARTIN, R ;
LAMARCHE, Y ;
TETREAULT, L .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1986, 33 (03) :300-307