AUTOCLAVABLE HIGHLY CROSS-LINKED POLYURETHANE NETWORKS IN OPHTHALMOLOGY

被引:17
作者
BRUIN, P
MEEUWSEN, EAJ
VANANDEL, MV
WORST, JGF
PENNINGS, AJ
机构
[1] UNIV GRONINGEN,DEPT POLYMER CHEM,9747 AG GRONINGEN,NETHERLANDS
[2] UNIV GRONINGEN,DEPT CELL BIOL,9713 EZ GRONINGEN,NETHERLANDS
[3] WORST RES GRP,9751 BM HAREN,NETHERLANDS
关键词
POLYURETHANES; NETWORKS; OPHTHALMOLOGY; INTRAOCULAR LENS; KERATOPROSTHESES;
D O I
10.1016/0142-9612(93)90210-S
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Highly cross-linked aliphatic polyurethane networks have been prepared by the bulk step reaction of low molecular weight polyols and hexamethylenediisocyanate (HDI). These polyurethane networks are optically transparent, colourless and autoclavable amorphous glassy thermosets, which are suited for use in ophthalmic applications such as intraocular lenses and keratoprostheses. The properties or these glassy polyurethanes, obtained from the reaction of the low molecular weight polyols triisopropanolamine (TIPA) or tetrakis(2-hydroxypropyl)ethylenediamine (Quadrol) and HDI in stoichiometric proportions, have been investigated in more detail. The glassy Quadrol/HDI-based polyurethane exhibits a reduction in ultimate glass transition temperature from 85 to 48 degrees C by uptake of 1% of water, and good ultimate mechanical properties (tensile strength 80-85 MPa, elongation at break ca 15%, modulus ca 1.5 GPa). IR spectra of these hydrophobic polyurethane networks revealed the absence of an isocyanate absorption, indicating that all isocyanates, apparently, had reacted during the crosslinking reaction. The biocompatibility could be increased by grafting tethered polyacrylamide chains onto the surface during network formation. These transparent cross-linked polyurethanes did not transmit UV light up to 400 nm, by incorporation of a small amount of the UV absorbing chromophore Coumarin 102, and could be sterilized simply by autoclaving. They were implanted in rabbit eyes, either in the form of small circular disks or in the form of a keratoprosthesis (artificial cornea). It was shown that the material was well tolerated by the rabbit eyes. Serious opacification of the cornea, a direct result of an adverse reaction to the implant, was never seen. Even 1 yr after implantation of a polyurethane keratoprosthesis the eye was still 'quiet'.
引用
收藏
页码:1089 / 1097
页数:9
相关论文
共 70 条
  • [1] SOFT INTRAOCULAR LENSES
    ALLARAKHIA, L
    KNOLL, RL
    LINDSTROM, RL
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (06) : 607 - 620
  • [2] ALPAR JJ, 1986, FECHNERS INTRAOCULAR
  • [3] MODEL NETWORKS OF END-LINKED POLYDIMETHYLSILOXANE CHAINS .12. DEPENDENCE OF ULTIMATE PROPERTIES ON DANGLING-CHAIN IRREGULARITIES
    ANDRADY, AL
    LLORENTE, MA
    SHARAF, MA
    RAHALKAR, RR
    MARK, JE
    SULLIVAN, JL
    YU, CU
    FALENDER, JR
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 1981, 26 (06) : 1829 - 1836
  • [4] COMPLICATIONS OF INTRAOCULAR LENSES - A HISTORICAL AND HISTOPATHOLOGICAL REVIEW
    APPLE, DJ
    MAMALIS, N
    LOFTFIELD, K
    GOOGE, JM
    NOVAK, LC
    KAVKAVANNORMAN, D
    BRADY, SE
    OLSON, RJ
    [J]. SURVEY OF OPHTHALMOLOGY, 1984, 29 (01) : 1 - 54
  • [5] ARONHIME MT, 1986, ADV POLYM SCI, V78, P84
  • [6] BOOTS HMJ, 1987, PHYSICA A, V14, P90
  • [7] BOOTS HMJ, 1988, BIOL SYNTHETIC POLYM, P267
  • [8] BOS M, IN PRESS
  • [9] BRANDRUP J, 1989, POLYM HDB
  • [10] EVALUATION OF THE BIOCOMPATIBILITY AND FIXATION OF A NEW SILICONE INTRAOCULAR-LENS IN THE FELINE MODEL
    BUCHEN, SY
    RICHARDS, SC
    SOLOMON, KD
    APPLE, DJ
    KNIGHT, PM
    CHRIST, R
    PHAM, LT
    NELSON, DL
    CLAYMAN, HM
    KARPINSKI, LG
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (05) : 545 - 553