Development and validation of an analytical method for quantification of 15 non-tricyclic antidepressants in serum with UPLC-MS/MS

被引:3
作者
Resende, Sara [1 ]
Deschrijver, Charlotte [2 ]
van de Velde, Eric [2 ]
Verstraete, Alain [1 ,2 ]
机构
[1] Univ Ghent, Dept Clin Chem Microbiol & Immunol, 185 Pintelaan,Bldg 2K12 IC, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Dept Lab Med, 185 Pintelaan,Bldg 2K12 IC, B-9000 Ghent, Belgium
关键词
Antidepressants; Serum; Analytical toxicology; UPLC-MS/MS;
D O I
10.1016/j.toxac.2016.06.002
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Objective. - Non-tricyclic antidepressants are often encountered in overdose cases, and for some of them therapeutic monitoring might be warranted. Therefore, we developed and validated an ultra-performance liquid chromatography-tandem mass spectrometry method for the quantification of 15 common non-tricyclic antidepressants in serum: citalopram, desmethylcitalopram, desmethylfluoxetine, desmethylvenlafaxine, duloxetine, fluoxetine, fluvoxamine, melitracen, mianserin, mirtazapine, paroxetine, reboxetine, sertraline, trazodone and venlafaxine. The selected pharmaceuticals represent the most common non-tricyclic antidepressants available in Belgium. Methods. - Serum samples (250 mu L) were precipitated with methanol and acetonitrile containing 5 ng of the internal standards: mirtazapine-D-4, paroxetine-D-5, reboxetine-D-6 and venlafaxine-D-6. The supernatant was evaporated at 56 degrees C under a flow of nitrogen and reconstituted in 100 mu L of 50: 50 methanol: water with 2 mM ammonium acetate. Five mu L were injected and the target analytes were separated on a 100 x 2.1 mm ACQUITY BEH C18 column (Waters, Zellik, Belgium) using a Waters ACQUITY Ultra-Performance Liquid Chromatography system. The analytes were eluted within 7.5 min, using a gradient of 2 mM ammonium acetate and 0.1% formic acid in water and in methanol at a flow rate of 0.4 mL/min. Quantification was performed on a Waters triple-quadrupole ACQUITY TQD using multiple reaction monitoring (MRM) in positive mode (2 MRMs per analyte). A six-point calibration curve was used to cover a large concentration range from 10 ng/mL to 1000 ng/mL. The developed method was validated in terms of selectivity, linearity, precision, accuracy, matrix effect, recovery and stability. Results. - No interfering signals from matrix, internal standard or tricyclic antidepressant drugs were found. Limits of quantification and limits of detection ranged from 10 to 85 ng/mL and 2.0 to 28 ng/mL respectively. Ion suppression from matrix effects varied from 36 to 108% for the compounds and 47 to 102% for the internal standards. Process efficiency varied from 22 to 106%. Intra-and interassay precision varied from 87.7 to 96.5% and 87.7 to 96.9%, respectively. The bias of the assay was lower than 15% for all the compounds, except the lowest concentrations of desmethylcitalopram and trazodone (bias < 20%). Conclusion. - Good validation performance was obtained thanks to the use of selected deuterated internal standards that adjusted for all of the compounds. This method is therefore suitable for quantification in suspected overdose cases and can be use in a clinical Toxicology lab in a daily basis. (C) 2016 Societe Francaise de Toxicologie Analytique. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:294 / 302
页数:9
相关论文
共 13 条
[1]   Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods [J].
Almeida, AM ;
Castel-Branco, MM ;
Falcao, AC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02) :215-222
[2]   Validation of liquid chromatographic and gas chromatographic methods - Applications to pharmacokinetics [J].
Bressolle, F ;
BrometPetit, M ;
Audran, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :3-10
[3]   Quantification of eight new antidepressants and five of their active metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry [J].
Castaing, Nadege ;
Titier, Karine ;
Receveur-Daurel, Mathilde ;
Le-Deodic, Maite ;
Le-bars, Delphine ;
Moore, Nicholas ;
Molimard, Mathieu .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (06) :334-341
[4]   Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses [J].
Chambers, Erin ;
Wagrowski-Diehl, Diane M. ;
Lu, Ziling ;
Mazzeo, Jeffrey R. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :22-34
[5]  
Gjerde H., 2011, Norsk Epidemiologi, V21, P5
[6]  
Hendrix L, EMERGMED
[7]   The Epidemiology of Depression Across Cultures [J].
Kessler, Ronald C. ;
Bromet, Evelyn J. .
ANNUAL REVIEW OF PUBLIC HEALTH, VOL 34, 2013, 34 :119-138
[8]   EPA guidance on mental health and economic crises in Europe [J].
Martin-Carrasco, M. ;
Evans-Lacko, S. ;
Dom, G. ;
Christodoulou, N. G. ;
Samochowiec, J. ;
Gonzalez-Fraile, E. ;
Bienkowski, P. ;
Gomez-Beneyto, M. ;
Dos Santos, M. J. H. ;
Wasserman, D. .
EUROPEAN ARCHIVES OF PSYCHIATRY AND CLINICAL NEUROSCIENCE, 2016, 266 (02) :89-124
[9]   Multi-analyte procedures for screening for and quantification of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LGMS/MS) relevant to clinical and forensic toxicology [J].
Maurer, HH .
CLINICAL BIOCHEMISTRY, 2005, 38 (04) :310-318
[10]   Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology [J].
Peters, Frank T. .
CLINICAL BIOCHEMISTRY, 2011, 44 (01) :54-65