THERMODILUTION RIGHT VENTRICULAR EJECTION FRACTION - CATHETER POSITIONING EFFECTS

被引:29
作者
SPINALE, FG
ZELLNER, JL
MUKHERJEE, R
FERRIS, SE
CRAWFORD, FA
机构
[1] BAXTER HEALTHCARE CORP,DIV ENGN,SANTA ANA,CA
[2] MED UNIV S CAROLINA,DEPT SURG,CHARLESTON,SC 29425
[3] CLEMSON UNIV,DEPT BIOENGN,CLEMSON,SC 29631
关键词
D O I
10.1378/chest.98.5.1259
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Right ventricular (RV) ejection fractions have been difficult to estimate clinically. It has been demonstrated recently that RV ejection fractions can be calculated by thermodilution techniques using a rapid response thermistor and computer. This method critically depends on adequate mixing of the thermal bolus and sensing of the rapid response thermistor. This study examined the effects of the thermistor position within the pulmonary artery and injectate site within the right atrium on RV thermodilution ejection fraction measurements. Ten pigs were instrumented with a RV thermodilution catheter in the pulmonary artery, an injectate catheter in the right atrium, an atrial-pacing and a systemic arterial catheter. The RV ejection fractions were determined using thermodilution in two ways: (1) with incremental increases in pulmonic valve to thermistor distance, and (2) with incremental increases in injectate port to tricuspid valve. These measurements were obtained at a paced rate of 107 ± 1 beats per minute (bpm) and then repeated with pacing-induced tachycardia (140 bpm). The highest RV ejection fraction with the lowest coefficient of variation was with the thermistor 2 cm from the pulmonic valve (50±2 percent), with a significant decline from this value at 10 cm (42±4 percent, p<0.05). This reduction in RV ejection fraction values with increased pulmonic valve to thermistor distance became more pronounced with tachycardia where a significant decline in RV ejection fraction occurred at 4 cm from the valve when compared with 0 cm (38±6 percent vs 47±3 percent, respectively, p<0.05). There was no significant change in RV ejection fraction at any injectate port to tricuspid valve distance at the lower heart rate. With tachycardia, however, a significant decline in RV ejection fraction occurred with the injectate port located 7 cm from the tricuspid valve (p<0.05). These results demonstrate that RV ejection fractions can be reliably obtained using thermodilution. Positioning of the thermodilution catheter is an important consideration for obtaining optimal RV ejection fraction measurements. Care should be taken to position the catheter with the thermistor a minimal distance from the pulmonic valve and the injectate port within the central body of the right atrium.
引用
收藏
页码:1259 / 1265
页数:7
相关论文
共 24 条
[1]   APPLICATIONS OF LAGGED NORMAL DENSITY CURVE AS A MODEL FOR ARTERIAL DILUTION CURVES [J].
BASSINGT.JB ;
ACKERMAN, FH ;
WOOD, EH .
CIRCULATION RESEARCH, 1966, 18 (04) :398-&
[2]   RADIONUCLIDE RIGHT VENTRICULAR EJECTION FRACTION - APPLICATIONS IN VALVULAR HEART-DISEASE [J].
BERGER, HJ ;
MATTHAY, R .
CHEST, 1981, 79 (05) :497-498
[3]  
BIONDI JW, 1988, ANESTH ANALG, V67, P144
[4]   BEDSIDE EVALUATION OF RIGHT VENTRICULAR PERFORMANCE USING A RAPID COMPUTERIZED THERMODILUTION METHOD [J].
DHAINAUT, JF ;
BRUNET, F ;
MONSALLIER, JF ;
VILLEMANT, D ;
DEVAUX, JY ;
KONNO, M ;
DEGOURNAY, JM ;
ARMAGANIDIS, A ;
IOTTI, G ;
HUYGHEBAERT, MF ;
LANORE, JJ .
CRITICAL CARE MEDICINE, 1987, 15 (02) :148-152
[5]   RIGHT VENTRICULAR DYSFUNCTION IN MULTIPLE TRAUMA VICTIMS [J].
EDDY, AC ;
RICE, CL ;
ANARDI, DM .
AMERICAN JOURNAL OF SURGERY, 1988, 155 (05) :712-715
[6]   RIGHT VENTRICULAR-FUNCTION IN ADULT CARDIOVASCULAR-DISEASE [J].
FERLINZ, J .
PROGRESS IN CARDIOVASCULAR DISEASES, 1982, 25 (03) :225-267
[7]  
Guide for the Care and Use of Laboratory Animals, NIH PUBLICATION
[8]   RIGHT VENTRICULAR VOLUMES BY THERMODILUTION IN THE ADULT RESPIRATORY-DISTRESS SYNDROME - A COMPARATIVE-STUDY USING TWO-DIMENSIONAL ECHOCARDIOGRAPHY AS A REFERENCE METHOD [J].
JARDIN, F ;
GUERET, P ;
DUBOURG, O ;
FARCOT, JC ;
MARGAIRAZ, A ;
BOURDARIAS, JP .
CHEST, 1985, 88 (01) :34-39
[9]   MEASUREMENT OF EJECTION FRACTION BY THERMAL DILUTION TECHNIQUES [J].
KAY, HR ;
AFSHARI, M ;
BARASH, P ;
WEBLER, W ;
ISKANDRIAN, A ;
BEMIS, C ;
HAKKI, AH ;
MUNDTH, ED .
JOURNAL OF SURGICAL RESEARCH, 1983, 34 (04) :337-346
[10]   RIGHT VENTRICULAR INFLUENCE ON LEFT-VENTRICULAR PERFORMANCE IN SEPTIC PATIENTS [J].
KNOBEL, E ;
FERNANDES, CJ ;
AKAMINE, N ;
ANDREI, AM ;
PLASTINO, FRT ;
KASINSKI, N ;
FEHER, J .
CRITICAL CARE MEDICINE, 1987, 15 (12) :1158-1159