IMPORTANCE OF HEART-RATE RESPONSE DURING EXERCISE IN PATIENTS USING ATRIOVENTRICULAR SYNCHRONOUS AND VENTRICULAR PACEMAKERS

被引:19
作者
MCMEEKIN, JD [1 ]
LAUTNER, D [1 ]
HANSON, S [1 ]
GULAMHUSEIN, SS [1 ]
机构
[1] UNIV SASKATCHEWAN HOSP,DEPT MED,DIV CARDIOL,SASKATOON S7N 0W8,SASKATCHEWAN,CANADA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 01期
关键词
dual chamber pacing; exercise hemodynamics; radionuclide ventriculography; rate‐adapted ventricular pacing; ventricular pacing;
D O I
10.1111/j.1540-8159.1990.tb02004.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrioventricular synchronous pacing offers advantages over fixed‐rate ventricular (VVI) pacing both at rest and during exercise. This study compared the hemodynamic effects at rest and exercise of ventricular pacing at a rate of 70 beats/mm, ventricular pacing where the rate was increased during exercise and duaJ chamber pacing. Ten patients, age 63.8 years, with multiprogrammable DDD pacemakers were studied using supine bicycle radionuclide ventriculography. RadionucJide data during dual chamber pacing was acquired at rest and during a submaximal workload of 200‐400 kpm/min. The pacemakers were then programmed to VVI pacing at a rate of 70 beats/min, and 1 week later, studies were repeated in the VVI mode at rest, during exercise at a rate of 70 beats/min, and during exercise with the WI pacemaker programmed to a rate adapted to the ODD pacing exercise rate. At rest, (he cardiac output was lower in the WI compared with the AV sequential mode (4.1 ±1.1 vs 5.7±1.1 1/mm, P < 0.01). During exercise, the cardiac output increased from resting values in the DDD and WI pacing modes, however cardiac output in the rate‐adapted WI mode was higher than in the WI mode with the rate maintained at 70 beats/min (8.1 ±1.5 vs 6.3 ±1.1 1/min, P = 0.02). Three patients completed lower workloads with WI pacing at 70 beats/min compared with AV synchronous pacing. At rest, AV sequential pacing was superior to WI pacing, suggesting the importance of the atrial contribution to ventricular filling. With WI pacing during exercise, cardiac output was improved with an increased pacemaker rate, suggesting that the heart rate response during exercise was the major determinant of the higher cardiac output. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:59 / 68
页数:10
相关论文
共 24 条
  • [11] THE HEMODYNAMIC IMPORTANCE OF ATRIOVENTRICULAR SYNCHRONY AND RATE INCREASE AT REST AND DURING EXERCISE
    KRISTENSSON, BE
    ARNMAN, K
    RYDEN, L
    [J]. EUROPEAN HEART JOURNAL, 1985, 6 (09) : 773 - 778
  • [12] A COMPARISON OF THE ACUTE AND LONG-TERM HEMODYNAMIC-EFFECTS OF VENTRICULAR INHIBITED AND ATRIAL SYNCHRONOUS VENTRICULAR INHIBITED PACING
    KRUSE, I
    ARNMAN, K
    CONRADSON, TB
    RYDEN, L
    [J]. CIRCULATION, 1982, 65 (05) : 846 - 855
  • [13] RADIONUCLIDE EVALUATION OF DUAL CHAMBER PACING - COMPARISON BETWEEN VARIABLE AV INTERVALS AND VENTRICULAR PACING
    LEMAN, RB
    KRATZ, JM
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : 408 - 414
  • [14] MEASUREMENT OF ABSOLUTE LEFT-VENTRICULAR VOLUME FROM GATED BLOOD POOL STUDIES
    LINKS, JM
    BECKER, LC
    SHINDLEDECKER, JG
    GUZMAN, P
    BUROW, RD
    NICKOLOFF, EL
    ALDERSON, PO
    WAGNER, HN
    [J]. CIRCULATION, 1982, 65 (01) : 82 - 91
  • [15] MCMEEKIN JD, 1986, CLIN INVEST MED, V9, pB33
  • [16] EVALUATION OF LEFT-VENTRICULAR PERFORMANCE BY RADIONUCLIDE VENTRICULOGRAPHY IN PATIENTS WITH ATRIOVENTRICULAR VERSUS VENTRICULAR DEMAND PACEMAKERS
    NITSCH, J
    SEIDERER, M
    BULL, U
    LUDERITZ, B
    [J]. AMERICAN HEART JOURNAL, 1984, 107 (05) : 906 - 911
  • [17] PEHRSSON SK, 1983, ACTA MED SCAND, V214, P305
  • [18] PERRINS EJ, 1983, BRIT HEART J, V50, P112
  • [19] LEFT-VENTRICULAR PERFORMANCE IN NORMAL SUBJECTS - A COMPARISON OF THE RESPONSES TO EXERCISE IN THE UPRIGHT AND SUPINE POSITIONS
    POLINER, LR
    DEHMER, GJ
    LEWIS, SE
    PARKEY, RW
    BLOMQVIST, CG
    WILLERSON, JT
    [J]. CIRCULATION, 1980, 62 (03) : 528 - 534
  • [20] RESPIRATION-DEPENDENT VENTRICULAR PACING COMPARED WITH FIXED VENTRICULAR AND ATRIAL-VENTRICULAR SYNCHRONOUS PACING - AEROBIC AND HEMODYNAMIC VARIABLES
    ROSSI, P
    ROGNONI, G
    OCCHETTA, E
    AINA, F
    PRANDO, MD
    PLICCHI, G
    MINELLA, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (03) : 646 - 652