BEHAVIOR OF AC HIGH VOLTAGE POLYAMIDE INSULATORS: EVOLUTION OF LEAKAGE CURRENT IN DIFFERENT SURFACE CONDITIONS

被引:12
|
作者
Slama, Mohammed El Amine [1 ]
Beroual, Abderrahmane [1 ]
机构
[1] Univ Lyon, CNRS, Ecole Cent Lyon, AMPERE UMR 5005, 36 Ave Guy Collongue, F-69134 Ecully, France
关键词
Dielectric; electrical arc; flashover; humidity; insulator; leakage current; partial discharges; pollution; polyamide;
D O I
10.15598/aeee.v13i2.1145
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper is aimed at a systematic study of the leakage current of high voltage polyamide insulator string under different conditions of pollution for possible application in the electric locomotive systems. It is shown that in the case of clean/dry and clean/wetted insulators, the leakage current and applied voltage are linear. While in the case of pollution with saline spray, the leakage current and the applied voltage are not linear; the leakage current changes from a linear regime to a nonlinear regime up to total flashover of the insulators sting. Traces of erosion and tracking of insulators resulting of partial discharges are observed.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [1] Experimental Study of the Flashover Process and the Leakage Current on the Surface of High Voltage Insulator Under AC Voltage
    Benguesmia, Hani
    Bakri, Badis
    Mekkas, Yasmine
    M'ziou, Nassima
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, : 2553 - 2567
  • [2] Statistical analysis of leakage current fluctuations on 20 kV high voltage porcelain insulators
    Tsarabaris, P. T.
    Halaris, P. G.
    Polykrati, A. D.
    Paraskevopoulos, A. A. P.
    Dimitriadou, D. D.
    Theodorou, N. J.
    PROCEEDINGS OF THE SIXTH IASTED INTERNATIONAL CONFERENCE ON EUROPEAN POWER AND ENERGY SYSTEMS, 2006, : 105 - +
  • [3] Leakage Current Prediction for High Voltage Insulators Flashover based on Extreme Value Theory
    Ali, Hui
    2016 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C), 2016, : 870 - 873
  • [4] The Leakage Current Components as a Diagnostic Tool to Estimate Contamination Level on High Voltage Insulators
    Salem, Ali A.
    Abd-Rahman, R.
    Al-Gailani, Samir Ahmed
    Kamarudin, M. S.
    Ahmad, Hussein
    Salam, Zainal
    IEEE ACCESS, 2020, 8 : 92514 - 92528
  • [5] Performance Evaluation of Insulators Using Flashover Voltage and Leakage Current
    Samimi, Mohammad Hamed
    Mostajabi, Amir Hossein
    Ahmadi-Joneidi, Iman
    Shayegani-Akmal, Amir Abbas
    Mohseni, Hossein
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (02) : 221 - 233
  • [6] Factors affecting the leakage current bursts of high voltage polluted insulators
    Gouda, OE
    Amer, GM
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 114 - 117
  • [7] Leakage Current Patterns on High Voltage Insulators: Analysis on Frequency and Time-frequency Domains
    Jayasundara, H. I. S.
    Sudarshani, W. P. S.
    Fernando, M. A. R. M.
    IEEE REGION 10 COLLOQUIUM AND THIRD INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS, VOLS 1 AND 2, 2008, : 291 - 296
  • [8] Investigations on the Effect of Voltage Harmonics on Leakage Current for Condition Monitoring in Insulators
    Ghosh, R.
    Chatterjee, B.
    Chakravorti, S.
    2016 IEEE 6TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2016,
  • [9] Influence of Partial Arc on Leakage Current and Surface Conductivity of Insulators
    Wang L.
    Li X.
    Cao B.
    Guo C.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (05): : 1624 - 1629
  • [10] Frequency characters of leakage current on the surface of outdoor insulators in different relative humidity
    Mao Yingke
    Guan Zhicheng
    Wang Liming
    Wang xin
    Yue Bo
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 692 - 695