Insulin pump users would not rule out using an implantable artificial pancreas

被引:5
作者
Taylor, M. J. [1 ]
Gregory, R. [2 ]
Mitchell, H. [3 ]
Alblihed, M. [4 ]
Alsabih, A. [5 ,6 ]
Tomlins, P. [1 ]
Sahota, T. S. [1 ]
机构
[1] De Montfort Univ, Fac Hlth & Life Sci, Leicester Sch Pharm, Leicester LE1 9BH, Leics, England
[2] Univ Hosp Leicester NHS Trust, Leicester Gen Hosp, Dept Diabet & Endocrinol, Leicester, Leics, England
[3] De Montfort Univ, Dept Psychol, Fac Hlth & Life Sci, Leicester, Leics, England
[4] Taif Univ, Coll Med, At Taif, Saudi Arabia
[5] King Saud Univ, Coll Med, Dept Physiol, Riyadh, Saudi Arabia
[6] King Saud Univ, KKUH, Riyadh, Saudi Arabia
关键词
insulin delivery; implantable insulin pump; CSII; type; 1; artificial pancreas;
D O I
10.1002/pdi.1822
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this survey was to establish the limitations of open loop continuous subcutaneous insulin infusion (CSII) as perceived by current users of the technology, and to ascertain their interest in and requirements for a non-electronic implantable closed loop insulin pump, INSmart, currently under development for the treatment of type 1 diabetes. INSmart has been surgically implanted in the peritoneum in animal models and continuously restored normoglycaemia. A bottom-up survey design was used to determine both positive and negative experiences of patients currently using CSII to define the performance characteristics they would require from a non-electronic, implantable closed loop insulin pump. A total of 360 insulin pump users completed the survey. All respondents had type 1 diabetes, were predominantly from English-speaking countries and had been diagnosed before age 34 years. Most had well controlled blood glucose (BG) according to their selfreported HbAic results. They reported a reduction in this value after transferring to CSII from multi-dose injections. However, 70% of pump users had more than three hypoglycaemic episodes per week. Eighty percent reported self-measured BG values > 10mmol/L three or more times per month; 94% of respondents considered a (non-electronic implantable) closed loop insulin pump would make their BG management easier and improve their quality of life. The majority of respondents felt there were still many disadvantages to current external insulin pumps such as their constant visible presence, rotation of insertion sites and skin inflammation. These shortfalls could be overcome by a device, such as INSmart, that provides a relatively instant feedback mechanism for controlling insulin release due to its proposed location in the peritoneal cavity. Copyright (C) 2014 John Wiley & Sons.
引用
收藏
页码:18 / 23A
页数:7
相关论文
共 22 条
  • [21] Preoperative oral supplementation with carbohydrate and branched-chain amino acid-enriched nutrient improves insulin resistance in patients undergoing a hepatectomy: a randomized clinical trial using an artificial pancreas
    Okabayashi, Takehiro
    Nishimori, Isao
    Yamashita, Koichi
    Sugimoto, Takeki
    Namikawa, Tsutomu
    Maeda, Hiromichi
    Yatabe, Tomoaki
    Hanazaki, Kazuhiro
    AMINO ACIDS, 2010, 38 (03) : 901 - 907
  • [22] Reducing the need for carbohydrate counting in type 1 diabetes using closed-loop automated insulin delivery (artificial pancreas) and empagliflozin: A randomized, controlled, non-inferiority, crossover pilot trial
    Haidar, Ahmad
    Yale, Jean-Francois
    Lovblom, Leif Erik
    Cardinez, Nancy
    Orszag, Andrej
    Falappa, C. Marcelo
    Gouchie-Provencher, Nikita
    Tsoukas, Michael A.
    El Fathi, Anas
    Rene, Jennifer
    Eldelekli, Devrim
    Lanctot, Sebastien O.
    Scarr, Daniel
    Perkins, Bruce A.
    DIABETES OBESITY & METABOLISM, 2021, 23 (06) : 1272 - 1281