Insulin pump users would not rule out using an implantable artificial pancreas

被引:5
|
作者
Taylor, M. J. [1 ]
Gregory, R. [2 ]
Mitchell, H. [3 ]
Alblihed, M. [4 ]
Alsabih, A. [5 ,6 ]
Tomlins, P. [1 ]
Sahota, T. S. [1 ]
机构
[1] De Montfort Univ, Fac Hlth & Life Sci, Leicester Sch Pharm, Leicester LE1 9BH, Leics, England
[2] Univ Hosp Leicester NHS Trust, Leicester Gen Hosp, Dept Diabet & Endocrinol, Leicester, Leics, England
[3] De Montfort Univ, Dept Psychol, Fac Hlth & Life Sci, Leicester, Leics, England
[4] Taif Univ, Coll Med, At Taif, Saudi Arabia
[5] King Saud Univ, Coll Med, Dept Physiol, Riyadh, Saudi Arabia
[6] King Saud Univ, KKUH, Riyadh, Saudi Arabia
关键词
insulin delivery; implantable insulin pump; CSII; type; 1; artificial pancreas;
D O I
10.1002/pdi.1822
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this survey was to establish the limitations of open loop continuous subcutaneous insulin infusion (CSII) as perceived by current users of the technology, and to ascertain their interest in and requirements for a non-electronic implantable closed loop insulin pump, INSmart, currently under development for the treatment of type 1 diabetes. INSmart has been surgically implanted in the peritoneum in animal models and continuously restored normoglycaemia. A bottom-up survey design was used to determine both positive and negative experiences of patients currently using CSII to define the performance characteristics they would require from a non-electronic, implantable closed loop insulin pump. A total of 360 insulin pump users completed the survey. All respondents had type 1 diabetes, were predominantly from English-speaking countries and had been diagnosed before age 34 years. Most had well controlled blood glucose (BG) according to their selfreported HbAic results. They reported a reduction in this value after transferring to CSII from multi-dose injections. However, 70% of pump users had more than three hypoglycaemic episodes per week. Eighty percent reported self-measured BG values > 10mmol/L three or more times per month; 94% of respondents considered a (non-electronic implantable) closed loop insulin pump would make their BG management easier and improve their quality of life. The majority of respondents felt there were still many disadvantages to current external insulin pumps such as their constant visible presence, rotation of insertion sites and skin inflammation. These shortfalls could be overcome by a device, such as INSmart, that provides a relatively instant feedback mechanism for controlling insulin release due to its proposed location in the peritoneal cavity. Copyright (C) 2014 John Wiley & Sons.
引用
收藏
页码:18 / 23A
页数:7
相关论文
共 22 条
  • [1] IMPLANTABLE INSULIN PUMP - FIRST STEP TOWARDS AN ARTIFICIAL PANCREAS
    VIX, M
    MUTTER, D
    JEANDIDIER, N
    BOIVIN, S
    PINGET, M
    MARESCAUX, J
    ANNALES DE CHIRURGIE, 1994, 48 (11): : 991 - 997
  • [2] From insulin pump and continuous glucose monitoring to the artificial pancreas
    Apablaza, Pamela
    Soto, Nestor
    Codner, Ethel
    REVISTA MEDICA DE CHILE, 2017, 145 (05) : 630 - 640
  • [3] Closed-loop glycaemic control using an implantable artificial pancreas in diabetic domestic pig (Sus scrofa domesticus)
    Taylor, M. J.
    Gregory, R.
    Tomlins, P.
    Jacob, D.
    Hubble, J.
    Sahota, T. S.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 500 (1-2) : 371 - 378
  • [4] Effect of intensive insulin therapy using an artificial pancreas in hepatic resection patients
    Okabayashi, Takehiro
    Maeda, Hiromichi
    Hanazaki, Kazuhiro
    ADVANCES IN BIOMEDICAL RESEARCH, PROCEEDINGS, 2010, : 122 - +
  • [5] QUANTITATIVE ANALYSIS OF TIME DELAYS OF GLUCOSE - INSULIN DYNAMICS USING ARTIFICIAL PANCREAS
    Rathee, Saloni
    Nilam
    DISCRETE AND CONTINUOUS DYNAMICAL SYSTEMS-SERIES B, 2015, 20 (09): : 3115 - 3129
  • [6] Engineering synthetic artificial pancreas using chitosan hydrogels integrated with glucose-responsive microspheres for insulin delivery
    Yin, Ruixue
    He, Jing
    Bai, Meirong
    Huang, Cong
    Wang, Kemin
    Zhang, Hongbo
    Yang, Shih-Mo
    Zhang, Wenjun
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 96 : 374 - 382
  • [7] Monitoring Statistical Properties of Kalman Filter Residuals in an Artificial Pancreas to Detect Overnight Pump Malfunctions Causing Insulin Suspension
    Manzoni, Eleonora
    Rampazzo, Mirco
    Facchinetti, Andrea
    Sparacino, Giovanni
    Del Favero, Simone
    CONTROL ENGINEERING PRACTICE, 2023, 141
  • [8] Glucose profiles in a type 1 diabetic patient successively treated with CSII using regular insulin, lispro and an implantable insulin pump
    Catargi, B
    Breilh, D
    Roger, P
    Tabarin, A
    DIABETES & METABOLISM, 2000, 26 (03): : 210 - 214
  • [9] Perioperative insulin therapy using a closed-loop artificial endocrine pancreas after hepatic resection
    Takehiro Okabayashi
    Hiromichi Maeda
    Robert A Montgomery
    Isao Nishimori
    kazuhiro Hanazaki
    World Journal of Gastroenterology, 2009, 15 (33) : 4116 - 4121
  • [10] Perioperative insulin therapy using a closed-loop artificial endocrine pancreas after hepatic resection
    Okabayashi, Takehiro
    Maeda, Hiromichi
    Sun, Zhao-Li
    Montgomery, Robert A.
    Nishimori, Isao
    Hanazaki, Kazuhiro
    WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (33) : 4116 - 4121