LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING

被引:151
|
作者
BELLIN, MF
ZAIM, S
AUBERTON, E
SARFATI, G
DURON, JJ
KHAYAT, D
GRELLET, J
机构
[1] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT SURG,F-75651 PARIS,FRANCE
[2] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT ONCOL,F-75651 PARIS,FRANCE
关键词
LIVER NEOPLASMS; LIVER; MR; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC);
D O I
10.1148/radiology.193.3.7972804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the clinical and biologic safety of superparamagnetic iron oxide (SPIO) as a contrast agent in magnetic resonance (MR) imaging and to assess its efficacy in the detection of liver metastases. MATERIALS AND METHODS: Twenty adults with liver metastases underwent MR imaging at 1.5 T before and 1 hour after infusion of SPIO. Four spin-echo (SE) sequences and One gradient-echo (GRE) sequence were used. RESULTS: There were no adverse reactions. Alterations in serum protein, serum iron, transferrin, and ferritin levels and transferrin saturation coefficient were statistically significant. The mean tumor-to-liver contrast-to-noise ratio (C/N) increased markedly with all sequences. The best postcontrast tumor-to-liver contrast was obtained with the GRE sequence (repetition time msec/echo time msec = 300/15). The mean number of apparent lesions detected after administration of SPIO increased by 12 with the proton-density-weighted SE sequences (800/30 and 2,500/30), four with the T2-weighted SE sequence (2,500/90), and seven with the GRE Sequence (300/15). CONCLUSION: SPIO is safe, increases tumor-to-liver C/Ns with some sequences, and improves the detection of liver metastases.
引用
收藏
页码:657 / 663
页数:7
相关论文
共 50 条
  • [41] MR-IMAGING OF ANOMALOUS LOBES OF THE LIVER
    KAKITSUBATA, Y
    KAKITSUBATA, S
    ASADA, K
    OCHIAI, R
    WATANABE, K
    ACTA RADIOLOGICA, 1993, 34 (04) : 417 - 419
  • [42] 1ST CLINICAL-TRIAL OF A NEW SUPERPARAMAGNETIC IRON-OXIDE FOR USE AS AN ORAL GASTROINTESTINAL CONTRAST AGENT IN MR IMAGING
    HAHN, PF
    STARK, DD
    LEWIS, JM
    SAINI, S
    ELIZONDO, G
    WEISSLEDER, R
    FRETZ, CJ
    FERRUCCI, JT
    RADIOLOGY, 1990, 175 (03) : 695 - 700
  • [43] SEGMENTAL IRON DEPOSITION IN THE LIVER DUE TO DECREASED INTRAHEPATIC PORTAL PERFUSION FINDINGS AT MR-IMAGING
    KADOYA, M
    MATSUI, O
    KITAGAWA, K
    KAWAMORI, Y
    YOSHIKAWA, J
    GABATA, T
    MIYAYAMA, S
    TAKASHIMA, T
    RADIOLOGY, 1994, 193 (03) : 671 - 676
  • [44] Preoperative breast cancer staging:: MR imaging of the axilla with ultrasmall superparamagnetic iron oxide enhancement
    Michel, SCA
    Keller, TM
    Fröhlich, JM
    Fink, D
    Caduff, R
    Seifert, B
    Marincek, B
    Kubik-Huch, RA
    RADIOLOGY, 2002, 225 (02) : 527 - 536
  • [45] INTRAVENOUS MR LYMPHOGRAPHY WITH SUPERPARAMAGNETIC IRON-OXIDE PARTICLES - EXPERIMENTAL STUDIES IN RATS AND RABBITS
    WAGNER, S
    PFEFFERER, D
    EBERT, W
    KRESSE, M
    TAUPITZ, M
    HAMM, B
    LAWACZECK, R
    SEMMLER, W
    WOLF, KJ
    EUROPEAN RADIOLOGY, 1995, 5 (06) : 640 - 646
  • [46] HEPATIC METASTASES - DETECTION WITH MULTISECTION FLASH MR-IMAGING DURING GADOLINIUM CHELATE ENHANCED ARTERIAL PORTOGRAPHY
    SOYER, P
    LAISSY, JP
    SIBERT, A
    AZENCOT, M
    VISSUZAINE, C
    MARMUSE, JP
    ACHOUR, E
    HERCOT, O
    MENU, Y
    RADIOLOGY, 1993, 189 (02) : 401 - 405
  • [47] ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    FELMLEE, JP
    GRIMM, RC
    RADIOLOGY, 1993, 189 (01) : 259 - 264
  • [48] INITIAL CLINICAL-EXPERIENCE WITH DEXTRAN-COATED SUPERPARAMAGNETIC IRON-OXIDE FOR DETECTION OF LYMPH-NODE METASTASES IN PATIENTS WITH HEAD AND NECK-CANCER
    ANZAI, Y
    BLACKWELL, KE
    HIRSCHOWITZ, SL
    ROGERS, JW
    SATO, Y
    YUH, WTC
    RUNGE, VM
    MORRIS, MR
    MCLACHLAN, SJ
    LUFKIN, RB
    RADIOLOGY, 1994, 192 (03) : 709 - 715
  • [49] HEMOCHROMATOSIS - DIAGNOSIS AND QUANTIFICATION OF LIVER IRON WITH GRADIENT-ECHO MR-IMAGING
    GANDON, Y
    GUYADER, D
    HEAUTOT, JF
    REDA, MI
    YAOUANQ, J
    BUHE, T
    BRISSOT, P
    CARSIN, M
    DEUGNIER, Y
    RADIOLOGY, 1994, 193 (02) : 533 - 538
  • [50] ASSESSMENT OF LIVER IRON OVERLOAD IN THALASSEMIC PATIENTS BY MR-IMAGING
    VILLARI, N
    CARAMELLA, D
    LIPPI, A
    GUAZZELLI, C
    ACTA RADIOLOGICA, 1992, 33 (04) : 347 - 350