LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING

被引:152
|
作者
BELLIN, MF
ZAIM, S
AUBERTON, E
SARFATI, G
DURON, JJ
KHAYAT, D
GRELLET, J
机构
[1] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT SURG,F-75651 PARIS,FRANCE
[2] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT ONCOL,F-75651 PARIS,FRANCE
关键词
LIVER NEOPLASMS; LIVER; MR; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC);
D O I
10.1148/radiology.193.3.7972804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the clinical and biologic safety of superparamagnetic iron oxide (SPIO) as a contrast agent in magnetic resonance (MR) imaging and to assess its efficacy in the detection of liver metastases. MATERIALS AND METHODS: Twenty adults with liver metastases underwent MR imaging at 1.5 T before and 1 hour after infusion of SPIO. Four spin-echo (SE) sequences and One gradient-echo (GRE) sequence were used. RESULTS: There were no adverse reactions. Alterations in serum protein, serum iron, transferrin, and ferritin levels and transferrin saturation coefficient were statistically significant. The mean tumor-to-liver contrast-to-noise ratio (C/N) increased markedly with all sequences. The best postcontrast tumor-to-liver contrast was obtained with the GRE sequence (repetition time msec/echo time msec = 300/15). The mean number of apparent lesions detected after administration of SPIO increased by 12 with the proton-density-weighted SE sequences (800/30 and 2,500/30), four with the T2-weighted SE sequence (2,500/90), and seven with the GRE Sequence (300/15). CONCLUSION: SPIO is safe, increases tumor-to-liver C/Ns with some sequences, and improves the detection of liver metastases.
引用
收藏
页码:657 / 663
页数:7
相关论文
共 50 条
  • [41] MAGNETIC-RESONANCE-IMAGING WITH SUPERPARAMAGNETIC IRON-OXIDE PARTICLES FOR THE DETECTION OF MYOCARDIAL REPERFUSION
    ROZENMAN, Y
    ZOU, XM
    KANTOR, HL
    MAGNETIC RESONANCE IMAGING, 1991, 9 (06) : 933 - 939
  • [42] Fast gradient echo MR imaging of the liver enhanced with superparamagnetic iron oxide
    Fishbein, M
    Long, F
    Smith, M
    MAGNETIC RESONANCE IMAGING, 1997, 15 (06) : 651 - 655
  • [43] Multifunctional pH-sensitive superparamagnetic iron-oxide nanocomposites for targeted drug delivery and MR imaging
    Zhu, Lijuan
    Wang, Dali
    Wei, Xuan
    Zhu, Xinyuan
    Li, Jianqi
    Tu, Chunlai
    Su, Yue
    Wu, Jieli
    Zhu, Bangshang
    Yan, Deyue
    JOURNAL OF CONTROLLED RELEASE, 2013, 169 (03) : 228 - 238
  • [44] ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE - AN INTRAVENOUS CONTRAST AGENT FOR ASSESSING LYMPH-NODES WITH MR IMAGING
    WEISSLEDER, R
    ELIZONDO, G
    WITTENBERG, J
    LEE, AS
    JOSEPHSON, L
    BRADY, TJ
    RADIOLOGY, 1990, 175 (02) : 494 - 498
  • [45] Noninvasive detection of liver fibrosis: Is superparamagnetic iron oxide particle (SPIO) enhanced MR imaging contributive technique?
    Lucidarme, O
    Baleston, F
    Bellin, M
    Cadi, M
    Grenier, PA
    RADIOLOGY, 2000, 217 : 505 - 505
  • [46] SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER
    FRETZ, CJ
    ELIZONDO, G
    WEISSLEDER, R
    HAHN, PF
    STARK, DD
    FERRUCCI, JT
    RADIOLOGY, 1989, 172 (02) : 393 - 397
  • [47] SUPERPARAMAGNETIC IRON-OXIDE PARTICLES - REPLY
    GORE, JC
    MAJUMDAR, S
    RADIOLOGY, 1988, 169 (03) : 657 - 658
  • [48] SUPERPARAMAGNETIC IRON-OXIDE - PHARMACOKINETICS AND TOXICITY
    WEISSLEDER, R
    STARK, DD
    ENGELSTAD, BL
    BACON, BR
    COMPTON, CC
    WHITE, DL
    JACOBS, P
    LEWIS, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (01) : 167 - 173
  • [49] A FUNCTIONALIZED SUPERPARAMAGNETIC IRON-OXIDE COLLOID AS A RECEPTOR DIRECTED MR CONTRAST AGENT
    JOSEPHSON, L
    GROMAN, EV
    MENZ, E
    LEWIS, JM
    BENGELE, H
    MAGNETIC RESONANCE IMAGING, 1990, 8 (05) : 637 - 646
  • [50] USE OF NEUTRAL SUPERPARAMAGNETIC IRON-OXIDE NANOPARTICLES AS CONTRAST AGENT FOR MR LYMPHOGRAPHY
    DEMARCO, G
    POULIQUEN, D
    PERDRISOT, R
    CHOULY, C
    LEJEUNE, JJ
    JALLET, P
    RADIOLOGY, 1992, 185 : 302 - 302