LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING

被引:152
|
作者
BELLIN, MF
ZAIM, S
AUBERTON, E
SARFATI, G
DURON, JJ
KHAYAT, D
GRELLET, J
机构
[1] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT SURG,F-75651 PARIS,FRANCE
[2] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT ONCOL,F-75651 PARIS,FRANCE
关键词
LIVER NEOPLASMS; LIVER; MR; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC);
D O I
10.1148/radiology.193.3.7972804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the clinical and biologic safety of superparamagnetic iron oxide (SPIO) as a contrast agent in magnetic resonance (MR) imaging and to assess its efficacy in the detection of liver metastases. MATERIALS AND METHODS: Twenty adults with liver metastases underwent MR imaging at 1.5 T before and 1 hour after infusion of SPIO. Four spin-echo (SE) sequences and One gradient-echo (GRE) sequence were used. RESULTS: There were no adverse reactions. Alterations in serum protein, serum iron, transferrin, and ferritin levels and transferrin saturation coefficient were statistically significant. The mean tumor-to-liver contrast-to-noise ratio (C/N) increased markedly with all sequences. The best postcontrast tumor-to-liver contrast was obtained with the GRE sequence (repetition time msec/echo time msec = 300/15). The mean number of apparent lesions detected after administration of SPIO increased by 12 with the proton-density-weighted SE sequences (800/30 and 2,500/30), four with the T2-weighted SE sequence (2,500/90), and seven with the GRE Sequence (300/15). CONCLUSION: SPIO is safe, increases tumor-to-liver C/Ns with some sequences, and improves the detection of liver metastases.
引用
收藏
页码:657 / 663
页数:7
相关论文
共 50 条
  • [31] ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE - CHARACTERIZATION OF A NEW CLASS OF CONTRAST AGENTS FOR MR IMAGING
    WEISSLEDER, R
    ELIZONDO, G
    WITTENBERG, J
    RABITO, CA
    BENGELE, HH
    JOSEPHSON, L
    RADIOLOGY, 1990, 175 (02) : 489 - 493
  • [32] EFFICACY OF BONE-SCINTIGRAPHY AND MR-IMAGING IN THE DETECTION OF SPINAL METASTASES
    CESANIVAZQUEZ, F
    CHALJUB, G
    BRISCOE, EG
    ALI, SA
    VILLANUEVAMEYER, J
    RADIOLOGY, 1995, 197 : 386 - 386
  • [33] Ultrasmall superparamagnetic iron oxide enhanced MR imaging for lymph node metastases
    Russell, Mai
    Anzai, Yoshimi
    RADIOGRAPHY, 2007, 13 : E73 - E84
  • [34] MR ENHANCEMENT OF HEPATOMA BY SUPERPARAMAGNETIC IRON-OXIDE (SPIO) PARTICLES
    YAMAMOTO, H
    YAMASHITA, Y
    YOSHIMATSU, S
    BABA, Y
    TAKAHASHI, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (04) : 665 - 667
  • [35] PHARMACOKINETICS OF SUPERPARAMAGNETIC IRON-OXIDE MR CONTRAST AGENTS IN THE RAT
    MAJUMDAR, S
    ZOGHBI, SS
    GORE, JC
    INVESTIGATIVE RADIOLOGY, 1990, 25 (07) : 771 - 777
  • [36] DEVELOPMENT OF HEPATOMA IN HYPERPLASTIC NODULES INDUCED IN RAT LIVERS - DETECTION WITH SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR-IMAGING
    YAMAMOTO, H
    YAMASHITA, Y
    TAKAHASHI, M
    RADIOLOGY, 1995, 197 : 414 - 414
  • [37] MR imaging lymphography with superparamagnetic iron oxide
    Schwartz, LH
    Koutcher, JA
    Matei, C
    Fisher, R
    McLachlan, SJ
    RADIOLOGY, 1997, 205 : 1273 - 1273
  • [38] Superparamagnetic iron oxide improves the detection of liver lesions at MR imaging: Multiobserver study with AFROC analysis
    Blakeborough, A
    Ward, J
    Wilson, D
    Kajiya, Y
    Guthrie, A
    Robinson, PJ
    RADIOLOGY, 1996, 201 : 1038 - 1038
  • [39] SUPERPARAMAGNETIC IRON-OXIDE USED AS A CONTRAST AGENT FOR MR IMAGING (MRI) IN MALIGNANT LIVER-TUMORS - A PRELIMINARY-STUDY
    GUYADER, D
    GANDON, Y
    BRUNET, F
    CARSIN, M
    ARTHAUD, A
    BONNEMAIN, B
    SIMON, J
    BRISSOT, P
    DEUGNIER, Y
    HEPATOLOGY, 1989, 10 (04) : 673 - 673
  • [40] Lymph node metastases: Safety and effectiveness of MR imaging with ultrasmall superparamagnetic iron oxide particles - Initial clinical experience
    Bellin, MF
    Roy, C
    Kinkel, K
    Thoumas, D
    Zaim, S
    Vanel, D
    Tuchmann, C
    Richard, F
    Jacqmin, D
    Delcourt, A
    Challier, E
    Lebret, T
    Cluzel, P
    RADIOLOGY, 1998, 207 (03) : 799 - 808